Laserfiche WebLink
BUILDING DOWNSPOUT <br />REFER TO ARCH'L EXTEND DOWNSPOUT AND <br />POINT DOWN OVER 6 _1 — it Ir Compacted Backfill <br />CENTER OF GRATE Bc II <br />'I 0 5B SII 2000# Concrete <br />8"X8" NYLOPLAST — _— LOAD FACTOR 2.3 <br />'=1 <br />RECTANGULAR, DUCTILE 0, 513c <br />SLOPE TO SLOPE TO IRON GRATE, OR Bc+12" Min. "Bc' Denotes outside CLASS A <br />DRAIN DRAIN APPROVED EQUIVALENT diameter of pipe <br />Concrete backfill to 0.5 <br />- of outside diameter with <br />1 ° 6 ° shaped bedding. <br />-I' COMPACTED SOIL <br />8" GRATE TO 4" PIPE INLINE <br />I�=1 DRAIN ADAPTER <br />N I I I CONCRETE COLLAR ON <br />COMPACTED BACK FILL <br />a <br />4" PVC SEWER RISER PIPE <br />12" (LENGTH AS REQUIRED) <br />4" PVC LONG RADIUS 4 <br />BEND SEWER ELBOW <br />4" PVC SEWER PIPE <br />CRUSHED AND <br />COMPACTED STONE <br />DOWNSPOUT TO PIPE CONNECTION <br />NTS <br />DIA + 3' <br />m.R,..s..r� <br />MATERIAL 1'-6" (MIN) <br />1. INSULATION BOARD TO BE CLOSED CELL. EXTRUDED POLYSTYRENE FOAM MEETING <br />ASTM 578, TYPE VI, 40PSI COMPRESSING STRENGTH (ASTM D1621) 0.1%MAX. WATER <br />ABSORPTION (ASTM C272). <br />2. BACKFILL MATERIAL AROUND INSULATION MUST BE FINE SAND FREE FROM ROOT, <br />ORGANIC MATERIAL, OR OTHER INJURIOUS MATERIALS. <br />3. OVERLAP ALL INSULATION BOARD JOINTS. <br />UTILITY PIPE INSULATION DETAIL <br />NTS <br />3" THICK <br />IRD (USE 2-2" <br />MASTIC ALL JOINTS <br />\TION BOARD DOWN <br />EPTH. <br />12" _ <br />/0-111 Compacted Backfill <br />Bc <br />-1 -1 + + + + + + + + I- <br />=1 + + + 0:513d- +11'- <br />+ + 111 Course Filter Aggregate <br />Bc/4 but not'=1 + + + + + + IIS- MnDOT Spec. 3149H Mod. <br />less than 6" =1 + + + + + + _SII <br />6" <br />_"'="'="'="'="'='' LOAD FACTOR 1.9 <br />Bc+12" Min. " Bc" Denotes outside CLASS B <br />diameter of pipe <br />Hand shaped from angular <br />bedding material <br />Bc/4 but not <br />less than 6" <br />Compacted Backfill <br />)utside <br />7e <br />LOAD FACTOR 1.5 <br />CLASS C-1 <br />Hand shaped from firm <br />undisturbed soil <br />Be VIII'- Compacted Backfill <br />-1 � I- <br />+ �c+++—IIIIII� Course Filter Aggregate <br />+ + + + + + _llI MnDOT Spec, 3149H Mod. <br />III—III—III-III-III-III - LOAD FACTOR 1.5 <br />"Bc' Denotes outside CLASS C-2 <br />Bc+12" Min. diameter of pipe <br />Hand shaped from angular <br />bedding material <br />PIPE BEDDING - RCP & DIP <br />NTS <br />Compacted Backfill <br />COR7 <br />R <br />0H aot <br />C� G3 © CUJ <br />4931 W. 35TH ST. SUITE 200 <br />ST. LOUIS PARK, MN 55416 <br />CivilSiteGroup.com <br />Matt Pavek Pat Sarver <br />763-213-3944 952-250-2003 <br />LAKE VIS <br />DEVELOPMENT, LLC <br />2'> -1 + + + + + + + + + + + + + + + + <br />+ + + + + + + + + + + + + + <br />+ ++ + + ++ + + + I= Granular Borrow <br />+++++++ Bc +++++++++ = (MnDOT Spec. <br />=1 + + + 1- <br />_I + + + + + I— 3149A modified) <br />+ + <br />III -III -III -III -III= � <br />U <br />W <br />Min,=Bc+12 "Bc" Denotes outside 0 <br />Of <br />diameter of pipe <br />IL <br />PIPE FOUNDATION & BEDDING IN GOOD SOILS <br />Compacted . <br />Backfill <br />Bedding <br />Foundation <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />—I <br />+ <br />+ <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+=' <br />=1 <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />Bc <br />+ <br />+ <br />+ <br />+ <br />+ <br />+I- <br />-� <br />+ <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />I- <br />-I <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />I— <br />=1 <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />=' <br />. <br />, + <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ <br />+ <br />+ <br />=' <br />able//�_ <br />"Bc" Denotes outside Minimum <br />diameter of pipe <br />2d+Bc+12" <br />12" <br />6" <br />-Course Filter <br />Agg. (MnDot Spec. <br />3149H Modified) <br />PIPE FOUNDATION & BEDDING IN POOR SOILS <br />PIPE BEDDING - PVC <br />NTS <br />T_ <br />M <br />L0 <br />L0 <br />5z <br />L <br />O <br />0 <br />0 <br />LUU <br />121- <br />O <br />O <br />M <br />Lo <br />J M <br />J L0 <br />., z <br />z <br />W z <br />M0 <br />a. Luz <br />Oz <br />J :E <br />W <br />N <br />W Lu <br />W Q <br />W 2 <br />Lo <br />QN <br />J <br />I HEREBY CERTIFY THAT THIS PLAN, <br />SPECIFICATION, OR REPORT WAS <br />PREPARED BY ME OR UNDER MY DIRECT <br />SUPERVISION AND THAT I AM A DULY <br />LICENSED PROFESSIONAL ENGINEER <br />UNDER THE LAWS OF THE STATE OF <br />MINNESOTA. <br />- Matthew R. Pavek <br />DATE 07/19/17 LICENSE NO. 44263 <br />ISSUE/SUBMITTAL SUMMARY <br />REVISION SUMMARY <br />PROJECT NO.: 17059 <br />PRELIMINARY CIVIL <br />DETAILS <br />C5.0 <br />COPYRIGHT 2017 CIVIL SITE GROU"NC <br />