Camp Teko <br /> Plumbing <br /> Plan No.011607 <br /> Page 2 <br /> November 28, 2000 <br /> 4. The clothes washer is not shown on either of the submitted riser diagrams. Verify that the individual waste, <br /> vent, and water supply lines are installed in accordance with the current Minnesota Plumbing Code. <br /> 5. Each bathroom is shown with common vented shower drains.To be common vented,the fixture drains must <br /> connect with a vertical drain at the same level. Otherwise, individual vent pipes must be provided on the <br /> dedicated fixture branches (see Minnesota Rules,part 4715.2580, subpart 1). <br /> 6. Where each shower space is not provided with an individual waste outlet,the waste outlet must be located <br /> and the floor pitched so that water from one shower does not flow over the floor area serving another <br /> shower(see Minnesota Rules,part 4715.1380, subpart 2). <br /> 7. Water closets in public bathrooms must have elongated bowls with open-front seats. The maximum water <br /> volume per flush of a floor-mounted water closet shall be 1.6 gallons. Water closets shall comply with <br /> American National Standards Institute A112.19.6-1990(see Minnesota Statutes,Section 326.37,subpart 2). <br /> 8. Faucets equipped with threaded hose connections must be provided with approved backflow preventers. <br /> This shall include the laundry tub faucet. <br /> 9. Showers or combination showers-baths shall be equipped with antiscald-type control valves. These valves <br /> must be of the thermostatic or pressure balance type in accordance with ANSUASSE Standard 1016-90(see <br /> Minnesota Rules,part 4715.1380, subpart 5). <br /> 10. Equipment used for heating water or storing hot water shall be protected by approved safety devices in <br /> accordance with Minnesota Rules,part 4715.2210 and part 4715.2230. Verify that a pressure and <br /> temperature relief valve exists. <br /> 11. A full-way valve must be provided on the cold water supply line to the water heater(see Minnesota Rules, <br /> part 4715.1800). <br /> 12. The copper water distribution piping must meet ASTM Standard B 88. <br /> 13. PVC plastic pipe used for the drain,waste,and vent system shall comply with ASTM Standard D 2665, <br /> D 2949 or F 891 (see Minnesota Rules,part 4715.0570 through part 4715.0600). <br /> 14. The water piping system shall be disinfected in accordance with Minnesota Rules,part 4715.2250. <br /> 15. The plumbing system shall be tested in accordance with Minnesota Rules,part 4715.2820. <br /> NOTE(S): <br /> 1. The scope of this project consists of constructing a park area bathroom facility. Installation includes a water <br /> heater, a water softener, a clothes washer, a laundry tub, several showers,and bathroom fixtures. <br /> 2. The building is served by new municipal sewer and a private well. <br />