Laserfiche WebLink
i <br /> ME <br /> PROJECT Camp Teko—:hadar Dining Hall Addition RRT Project #0206.05 <br /> TO Lyle Oman <br /> FROM Leon Wang _ <br /> SUBJECT Proposal For Camp Teko Restroom Fixture Count <br /> DATE 6 November 2002 <br /> PRESENT <br /> Camp Teko, 645 Tonkawa Road, Orono, MN <br /> Proposal for Chadar Dining Hall Addition Restroom Fixture Count <br /> The following is a proposal regarding the restroom fixture count in the new Chadar dining hall addition. <br /> Please see attached list of existing and planned restroom fixture for the entire Camp Teko facility. A <br /> site plan of the camp and floor plans of the Chadar building and addition is also enclosed for your <br /> reference. <br /> As you may recall, this project involves a two-level, 1,400 sq. ft. (per level) addition to the existing <br /> Chadar dining hall. The new addition will require the demolition of existing toilet rooms. Two new <br /> handicap accessible restroom facilities will be included in the plans for the new addition. <br /> Aside from the new restrooms in the proposed additions, the Chadar building will have two bathrooms <br /> serving the private quarters. In addition, the camp has a restroom/shower building (built in 2001) <br /> which contains accessible fixtures. Please see attached for listings and locations of the afore <br /> mentioned restroom facilities. <br /> We hereby request your consent to allow the number of restroom fixtures in the new Chadar addition <br /> and the 2001 restroom building to be counted collective towards the required fixture count. This <br /> proposal would add two accessible restrooms in the Chadar building, in addition to the restroom <br /> facilities in the 2001 building serving the overall camp. Please see the attached list for a summation <br /> of the fixture number and type based on this proposal. <br /> Please note that based on the occupancy load of the Chadar building (with addition), the required <br /> fixture count is 3 WCs and 3 lav/basins for women and 3 urinal/WCs and 3 lav/basins for men. This <br /> requirement only applies if the Chadar building/addition is to be considered separately from the camp. <br /> Thank you for your consideration. Please contact me if you have any questions. <br /> Sincerely, <br /> Leon Wang <br /> xc: file, Bob Shiff, Barbara Brooks, Alan Engler <br /> RAFFERTY RAFFERTY TOLLEFSON ARCHITECTS <br /> 253 EAST 4TH STREET SAINT PAUL, MINNESOTA 55101-1632 <br /> TEL: 651 2Z4-4831 FAX: 651 228-0264 <br /> 0 <br /> GV20605101 Pre-Construction files\03 Cor W"AKn' eX#19T 'n(Krl Opportunity Employer <br />