Laserfiche WebLink
PC Exhibit E <br />November 22, 2016 <br />Re: Building Code Review for Daycare Occupancies <br />2060 Wayzata Blvd, Orono, MN <br />Mohagen Hansen Project No.: 16403.003S <br />This document will providea basic code review for the building located at 2060 Wayzata Blvd, Orono, <br />MN. This code review will be focused on providing the requirements for an occupancy for a Day Care <br />within the Minnesota State Building Code 2015 and the MN State Fire Code 2015. This review does not <br />include the MN Chapter 9503 Child Care Center Licensing. <br />Basic Building Current lnformatiQn: <br />1. Occupancy: B (Business) <br />2. Building Construction Type: Type V -B <br />3. Stories: 1 with a Mezzanine and Basement <br />4. Square Feet per Floor: Basement Level' 1563 SF; Main Level: 1546 SF; Mezzanine: 749 <br />SF <br />5. Sprinkled Fully Sprinkled, NFPA 13 <br />6. Exiting 2 exits, one on main level and one on basement level <br />Day CareRevie <br />1. Occupancy Classification Table 302.2 <br />a. More than 5 children under 2.5 years of age without exit on level of classrooms: 1-4 <br />i. Mezzanine level: 1-4 occupancy not allowed by item #14 <br />b. More than 5 but less than 100 children less than 2.5 years on level of exit: <br />i. Main level or Basement level: E occupancy with direct access out of classroom. <br />Exit doors need to be added. <br />c. More than5 children greater than 2.5 years: E <br />L Main level or Basement level: E occupancy, no additional exiting required <br />ii. Mezzanine level: E occupancy if exit door is added. <br />2. Table 503 Building Height and Size: E <br />Allowable: 1stories and 9,500SF per floor <br />Provided: 2 stories and approx.. 1600 SF or less per floor <br />3. 504.2 Automatic sprinkler system increase. <br />a. Allowable stories increased by one story. <br />4. Table 803.9 Interior Finish Requirements for Flame Spreads <br />Group E: Exits - Group B <br />Corridors, Rooms = Group C <br />Flame spread for C: 76-200 <br />Smoke Development Index: 0-450 <br />5. 906 Fire Extinguisher: to be located a maximum travel distance of 75'-0" <br />6. Table 1004.1.4 Maximum floor area per occupant: cls <br />Group E: Day care:35 - any classroom over 1,715 SF needs two exits <br />7. 1008.1.10: Panic Hardware: Group E: is Required, JAN 17 2017 <br />8. 1009 Stairways <br />I Nll TC.' %a ?alts C3111T Dive I 31tE 290, �'Vaprasa, r"'; -': r 3898 CITY OF ORONO <br />