PROJECT SCOPE <br />DESIGN OF CAST -IN-PLACE CONCRETE AND WOOD FRAMING FOR A PROPOSED DETACHED CARRIAGE HOUSE. CONSTRUCTION IS TO <br />BE DONE IN ACCORDANCE WITH THESE DRAWINGS, STANDARD INDUSTRY PRACTICE, AND THE REQUIREMENTS OF THE CODE. <br />GENERAL NOTES <br />1. THESE DOCUMENTS APPLY TO STRUCTURAL ONLY. REFER TO HOUSE PLANS PREPARED BY ESKUCHE DESIGN LAST DATED <br />4-19-18 FOR MORE INFORMATION. <br />2. IT IS THE RESPONSIBILITY OF THE BUILDER TO PROVIDE ALL FUTURE PLAN OR FIELD CHANGES TO THE HANSON GROUP FOR <br />REVIEW. PROVIDE FINAL TRUSS LAYOUTS TO THE HANSON GROUP PRIOR TO CONSTRUCTION AND MATERIAL ACQUISITION. <br />3. ADEQUATE SHORING DURING CONSTRUCTION IS THE RESPONSIBILITY OF THE CONTRACTOR. <br />4. CONTRACTOR AND BUILDER ARE TO VERIFY ALL DIMENSIONS AND CONDITIONS BEFORE PROCEEDING WITH WORK. NOTIFY THE <br />HANSON GROUP IF DISCREPANCIES ARISE. <br />5. MEANS AND METHODS OF CONSTRUCTION ARE THE RESPONSIBILITY OF THE CONTRACTOR. <br />FOUNDATION NOTES <br />1. DRAIN TILE, DAMPPROOFING AND/OR WATERPROOFING, & INSULATION, AS WELL AS THEIR INSTALLATION, ARE TO BE IN <br />ACCORDANCE WITH THE CODE. <br />2. INSTALL A MINIMUM OF (2) ANCHORS PER PORTION OF SILL PLATE AS WELL AS AN ANCHOR WITHIN 12" OF EACH END AS <br />APPLICABLE. <br />3. BAR SPLICES ARE TO BE LAPPED A MINIMUM OF 48 BAR DIAMETERS. PROVIDE 48" MATCHING HOOK BARS FOR ALL HORIZONTAL <br />BARS AT WALL CORNERS AND INTERSECTIONS. <br />4. CARE IS TO BE TAKEN DURING BACKFILLING TO MAINTAIN A PLUMB WALL ALIGNMENT. <br />5. BACKFILL BELOW EXTERIOR STOOP SLABS WITH COMPACTED GRANULAR MATERIAL TO FROST DEPTH (4'-0" MINIMUM). <br />6. PRIOR TO BACKFILLING, FOUNDATION WALLS ARE TO BE LATERALLY SUPPORTED BY FLOOR SLAB OR BY ADEQUATE TEMPORARY <br />BRACING. <br />7. SITE ELEMENTS INCLUDING LANDSCAPING RETAINING WALLS ARE NOT INCLUDED IN THE SCOPE OF THESE DRAWINGS. <br />FRAMING NOTES <br />1. ALL DIMENSION LUMBER HEADERS AND BEAMS ARE TO HAVE A MINIMUM OF ONE BEARING STUD AT EACH END. ALL 2 -PLY LVL <br />AND GIRDER TRUSS BEAMS AND HEADERS ARE TO HAVE A MINIMUM OF TWO BEARING STUDS AT EACH END. 3 -PLY MEMBERS <br />ARE TO HAVE A MINIMUM OF THREE BEARING STUDS AT EACH END. ALL BEARING ABOVE IS UNLESS NOTED OTHERWISE ON <br />PLANS. TRUSS SUPPLIER IS TO VERIFY GIRDER TRUSS BEARING LENGTH AND SUPPORT REQUIREMENTS. <br />2. ALL HEADERS AND BEAMS ARE TO HAVE A MINIMUM OF ONE FULL HEIGHT KING STUD AT EACH END. EXTERIOR OPENINGS <br />GREATER THAN SIX FEET IN WIDTH ARE TO HAVE A MINIMUM OF TWO FULL HEIGHT KING STUDS AT EACH END. EXTERIOR <br />OPENINGS GREATER THAN TEN FEET IN WIDTH ARE TO HAVE A MINIMUM OF THREE FULL HEIGHT KING STUDS AT EACH END. <br />3. ALL CONNECTIONS ARE TO BE MADE WITH ADEQUATE SIMPSON, USP OR EQUAL JOIST HANGERS, CLIPS, POST CAPS, AND POST <br />BASES. <br />4. CONNECT MULTIPLE MEMBER LVUS TOGETHER IN ACCORDANCE WITH MANUFACTURER REQUIREMENTS. <br />5. ALL EXTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, U.N.O., WHICH MEETS OR <br />EXCEEDS THE REQUIREMENTS OF CODE SECTION R602.10.4 WSP AND CS-WSP. <br />A. 2x6 STUDS SPACED @ 16" O.C. <br />B. WALL SHEATHING: �/16" MIN. STRUCTURAL PANEL SHEATHING w/ 8d NAILS @ 6" O.0 AT PANEL EDGES AND 12" O.C. AT <br />INTERMEDIATE SUPPORTS OR 13/" 16 GAUGE STAPLES @ 3" / 6" SPACING. <br />6. ALL INTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, U.N.O. <br />A. 2x4 OR 2x6 STUDS SPACED @ 16" O.C. <br />B. WALL SHEATHING: %" MIN. GYPSUM SHEATHING FASTENED TO FRAMING w/ 5d COOLER NAILS @ 8" O.C. MAX. OR TYPE S/W <br />WALLBOARD SCREWS @ 16" O.C. MAX. (5/" MINIMUM STUD PENETRATION) <br />7. ALL ROOFS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA. <br />A. ROOF FRAMING SPACED AT A MAXIMUM OF 24" O.C. <br />B. FASTEN ALL ROOF FRAMING TO TOP PLATES WITH USP RT7 OR SIMPSON H2.5 CLIPS OR EQUIVALENT AND (3) 8d TOENAILS. <br />C. ROOF SHEATHING: %2" MIN. STRUCTURAL PANEL SHEATHING w/ 8d NAILS @ 6" O.0 AT PANEL EDGES AND 12" O.C. AT <br />INTERMEDIATE SUPPORTS OR 13/" 16 GAUGE STAPLES @ 3" / 6" SPACING. <br />D. PROVIDE FULL DEPTH BLOCKING BETWEEN TRUSSES AT ENERGY HEELS FOR PERIMETER ROOF SHEATHING NAILING OR TOP <br />AND BOTTOM BLOCKING SHEATHED PER FRAMING NOTE 6. BLOCKING TO EXTEND FROM WALL TOP PLATES TO WITHIN 2" OF <br />ROOF SHEATHING. <br />8. ALL OTHER FASTENERS TO BE IN ACCORDANCE CODE TABLE R602.3(1). <br />9. ALL STUD PLIES IN BUILT UP COLUMNS AND AT INTERMEDIATE STUD FRAMING TO BE FASTENED TO SHEATHING / GYP BOARD AS <br />NOTED ABOVE (12" O.C. MAX. AT EXTERIOR AND 16" O.C. MAX. AT INTERIOR). <br />10. ALL STONE IS TO BE THIN VENEER ADEQUATELY ADHERED BACK TO WOOD FRAMING FOR CONTINUOUS VERTICAL AND LATERAL <br />SUPPORT BY THE MASON. <br />11. A BRACED WALL REVIEW HAS BEEN PERFORMED. DUE TO FULL ENGINEERING PROVIDED, EXTERIOR BRACED WALLS ARE NOT <br />SHOWN FOR CLARITY, BUT ARE COVERED BY CONTINUOUS SHEATHING AND CONNECTIONS NOTED ABOVE. <br />MATERIALS <br />CONCRETE FOOTINGS: <br />F'c = 5,000 PSI @ 28 DAYS (OR 3,500 PSI WITH AN APPROVED ADMIXTURE THAT <br />2x6 MIN. TREATED SILL PLATE <br />PROVIDES A WATER AND VAPOR RESISTANCE AT LEAST EQUIVALENT TO 5,000 PSI CONCRETE <br />CONCRETE WALLS: <br />F'c = 3,500 PSI @ 28 DAYS <br />REINFORCING STEEL: <br />ASTM A615 GRADE 60 <br />AGGREGATE: <br />FOOTINGS - 1%" MAX <br />WALLS/SLABS- %4" MAX <br />ON-SITE SOIL: <br />SANDY -CLAY (GROUP 11) ASSUMED <br />THE HANSON GROUP IF <br />\ <br />yeq = 45 PSF/FT (ACTIVE) <br />FROM FOUNDATION 6 <br />IF CLAY SOILS ARE ENCOUNTERED, BACKFILL w/ SAND FULL HEIGHT <br />BACKFILL SOIL: <br />SAND (GROUP 1) TO BE USED WHERE NOTED: <br />yeq = 30 PSF/FT (ACTIVE) <br />WALL STUDS (10' OR LESS): <br />SPF STUD GRADE OR BETTER <br />WALL STUDS (OVER 10'): <br />SPF NO.2 GRADE OR BETTER <br />DIMENSIONAL LUMBER: <br />SPF NO.2 GRADE OR BETTER <br />TREATED LUMBER: <br />SYP NO.2 GRADE OR BETTER <br />LVL: <br />13/" WIDTH - Fb = 2600 PSI, E = 1,900,000 PSI <br />ALLOWABLE SOIL <br />BEARING PRESSURE: <br />2,000 PSF (ASSUMED) <br />LOADS <br />ROOF LIVE LOAD: 35 PSF (SNOW) <br />ROOF DEAD LOAD: 20 PSF <br />WIND LOAD: 90 MPH EXP. B <br />THIN STONE: 25 PSF MAX. <br />CODES <br />2015 MINNESOTA RESIDENTIAL CODE <br />@ COPYRIGHT HANSON GROUP, LLC 2018 <br />BUILDER TO VERIFY IF <br />FROST FOOTINGS ARE <br />REQ'D BELOW INTERIOR <br />NON-BEARING WALLS <br />1 REFERENCE PLAN <br />S1 FOUNDATION PLAN SHOWN FOR <br />LOCATION REFERENCE ONLY <br />FRAME WALL ABOVE <br />2x6 MIN. TREATED SILL PLATE <br />2"O x 10" LONG ANCHOR <br />w/ NO PLATE OVERHANG <br />BOLTS (7" MIN. EMBED) <br />@ 72" O.C. MAX. OR EQUIV. <br />MAINTAIN 6" MIN. STEM WALL <br />SUPPLIER - CONTACT <br />SLAB -ON -GRADE <br />SLOPE GRADE AWAY <br />THE HANSON GROUP IF <br />\ <br />(2) 2,x10 <br />FROM FOUNDATION 6 <br />ID <br />DESIGN ASSISTANCE IS <br />MIN. <br />— — — — — — — -------�-- <br />---- <br />--� REQUIRED <br />17'-81 4" <br />III <br />Flo <br />5'-101 2� <br />4" <br />2" LEDGE <br />#4 HORIZ. BAR @TOP OF WALL <br />8" MIN. C.I.P. <br />BAR E <br />STORAGE <br />a <br />a <br />CONCRETE WALL <br />#4 x 2'-0" DOWELS <br />@ 72" O.C. <br />/7 <br />20" WIDE x 8" DEEP MIN. <br />(5" MIN. EMBED) <br />CONCRETE STRIP FOOTING <br />CENTERED IN WALL <br />ETf <br />0 <br />CENTERED UNDER WALL <br />- LOWER AS REQ'D FOR <br />FROST PROTECTION <br />3 WALL SECTION <br />S1 FROST FOUNDATION WALL - <br />WALKOUT <br />THIN STONE AND INSULATION <br />AT EXTERIOR NOT SHOWN <br />FOR CLARITY TYP. ALL <br />SECTIONS - BY OTHERS <br />FRAME WALL ABOVE <br />2x6 MIN. TREATED SILL PLATE <br />w/ NO PLATE OVERHANG <br />MAINTAIN 6" MIN. STEM WALL <br />(2-0" MAX. HEIGHT) <br />SLOPE GRADE AWAY <br />FROM FOUNDATION 6„ <br />MIN. <br />III <br />#4 HORIZ. BAR @ TOP OF WALL <br />#4 x 2'-0" DOWELS <br />@ 72" O.C. <br />(5" MIN. EMBED) <br />CENTERED IN WALL <br />---------I------------------------------------il <br />`-- <br />f 1 <br />Fe <br />1 VENT. 0.0 <br />I <br />I <br />t <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I J <br />I <br />I > <br />I _ <br />I <br />I tr r <br />I ,- <br />I N <br />i <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />i <br />I <br />J I <br />I <br />1J I <br />CIONC. STOOP <br />'N <br />ROOF TRUSS SPAN <br />BY SUPPLIER <br />TYP. <br />GT BY SUPPLIER <br />TYP. <br />\ <br />OVERHANGS BY <br />HVAC <br />SUPPLIER - CONTACT <br />1 <br />THE HANSON GROUP IF <br />\ <br />(2) 2,x10 <br />ID <br />DESIGN ASSISTANCE IS <br />— — — — — — — -------�-- <br />---- <br />--� REQUIRED <br />17'-81 4" <br />a <br />Flo <br />5'-101 2� <br />4" <br />� <br />BAR E <br />STORAGE <br />I <br />n <br />/7 <br />0 <br />i <br />I <br />J I <br />I <br />1J I <br />CIONC. STOOP <br />'N <br />ROOF TRUSS SPAN <br />BY SUPPLIER <br />TYP. <br />GT BY SUPPLIER <br />TYP. <br />(3) 2x6 BRG FOR LVL (1) <br />2x6 BRG FOR 2x10's AND <br />(2) 2x6 FULL HEIGHT <br />KING STUDS BETWEEN <br />%2"O x 10" LONG ANCHOR <br />BOLTS (7" MIN. EMBED) <br />@ 72" O.C. MAX. OR EQUIV. _ <br />eo <br />SLAB -ON -GRADE <br />L� F2" LEDGE <br />8" MIN. C.I.P <br />a CONCRETE WALL <br />a <br />20" WIDE x 8" DEEP MIN. <br />CONCRETE STRIP FOOTING <br />CENTERED UNDER WALL <br />- LOWER AS REQ'D FOR <br />FROST PROTECTION <br />4 WALL SECTION <br />S1 FROST FOUNDATION WALL w/ <br />RAISED STEM TYP. <br />2 REFERENCE PLAN <br />S1 MAIN LEVEL PLAN SHOWN FOR <br />LOCATION REFERENCE ONLY <br />%2"O x 10" LONG ANCHOR <br />BOLTS (7" MIN. EMBED) <br />@ 72" O.C. MAX. OR EQUIV. <br />8" MIN. C.I.P. CONCRETE WALL <br />• a <br />#4 HORIZ. BARS III_ <br />@ 24" O.C. <br />a II � II <br />N #4 x 3'-0" HOOKS <br />@ 36" O.C. �- <br />6" <br />SLAB -ON -GRADE <br />THICKEN WALL TO 10" BELOW <br />SLAB FOR OPTIONAL SLAB LEDGE <br />M <br />(2) 2x6 BRG AT THE <br />ENDS OF ALL GT's <br />TYP. <br />FRAME WALL ABOVE <br />SLOPE GRADE <br />6" AWAY FROM <br />91N. /—FOUNDATION <br />#4 VERT. BARS @ 36" O.C. <br />2" TO VERT. BARS & HOOKS <br />5 WALL SECTION <br />S1 RETAINING WALL TYPE <br />FOUNDATION WALL <br />20" WIDE x 8" DEEP MIN. <br />CONCRETE STRIP FOOTING <br />CENTERED ON WALL <br />- LOWER AS REQ'D FOR <br />FROST PROTECTION <br />Eskuche Design <br />18318 Minnetonka Blvd <br />Deephaven, MN 55391 <br />Revision Date Description <br />PLANS SHOWN LIGHT IN BACKGROUND ARE FOR <br />LOCATION REFERENCE ONLY. PLAN NOTES AND <br />ELEMENTS SHOWN LIGHT MAY NOT NECESSARILY <br />SUPPORT THE HANSON GROUP'S DESIGN. <br />BUILDER IS REQUIRED TO SEND FINAL TRUSS <br />LAYOUT DRAWINGS TO THE HANSON GROUP <br />PRIOR TO CONSTRUCTION FOR VERIFICATION OF <br />LOAD PATHS AND FRAMING SIZES LISTED <br />I hereby certify that this plan, specification or report <br />was prepared by me or under my direct supervision <br />and that I am a duly Licensed Professional Engineer <br />under the laws of the State of Min sota. <br />i <br />Signed: <br />Print Name: TrevorLer <br />Date: 4-26-18 License Number: 45470 <br />3407 Kilmer Lane North <br />Suite 4 <br />Plymouth, MN 55441 <br />Tel 612-708-3572 <br />www.hansongroupmn.com <br />Maxwell Modern <br />Carriage House <br />1020 Tonkawa Rd <br />Orono, MN <br />Project Number: 7.292 <br />Date: April 26, 2018 <br />Sheets: 1 of 1 S1 <br />\ <br />OVERHANGS BY <br />SUPPLIER - CONTACT <br />1 <br />THE HANSON GROUP IF <br />\ <br />(2) 2,x10 <br />(3) 11%$" LVL <br />DESIGN ASSISTANCE IS <br />— — — — — — — -------�-- <br />---- <br />--� REQUIRED <br />$— -------- ,-�, <br />� <br />(3) 2x6 BRG FOR LVL (1) <br />2x6 BRG FOR 2x10's AND <br />(2) 2x6 FULL HEIGHT <br />KING STUDS BETWEEN <br />%2"O x 10" LONG ANCHOR <br />BOLTS (7" MIN. EMBED) <br />@ 72" O.C. MAX. OR EQUIV. _ <br />eo <br />SLAB -ON -GRADE <br />L� F2" LEDGE <br />8" MIN. C.I.P <br />a CONCRETE WALL <br />a <br />20" WIDE x 8" DEEP MIN. <br />CONCRETE STRIP FOOTING <br />CENTERED UNDER WALL <br />- LOWER AS REQ'D FOR <br />FROST PROTECTION <br />4 WALL SECTION <br />S1 FROST FOUNDATION WALL w/ <br />RAISED STEM TYP. <br />2 REFERENCE PLAN <br />S1 MAIN LEVEL PLAN SHOWN FOR <br />LOCATION REFERENCE ONLY <br />%2"O x 10" LONG ANCHOR <br />BOLTS (7" MIN. EMBED) <br />@ 72" O.C. MAX. OR EQUIV. <br />8" MIN. C.I.P. CONCRETE WALL <br />• a <br />#4 HORIZ. BARS III_ <br />@ 24" O.C. <br />a II � II <br />N #4 x 3'-0" HOOKS <br />@ 36" O.C. �- <br />6" <br />SLAB -ON -GRADE <br />THICKEN WALL TO 10" BELOW <br />SLAB FOR OPTIONAL SLAB LEDGE <br />M <br />(2) 2x6 BRG AT THE <br />ENDS OF ALL GT's <br />TYP. <br />FRAME WALL ABOVE <br />SLOPE GRADE <br />6" AWAY FROM <br />91N. /—FOUNDATION <br />#4 VERT. BARS @ 36" O.C. <br />2" TO VERT. BARS & HOOKS <br />5 WALL SECTION <br />S1 RETAINING WALL TYPE <br />FOUNDATION WALL <br />20" WIDE x 8" DEEP MIN. <br />CONCRETE STRIP FOOTING <br />CENTERED ON WALL <br />- LOWER AS REQ'D FOR <br />FROST PROTECTION <br />Eskuche Design <br />18318 Minnetonka Blvd <br />Deephaven, MN 55391 <br />Revision Date Description <br />PLANS SHOWN LIGHT IN BACKGROUND ARE FOR <br />LOCATION REFERENCE ONLY. PLAN NOTES AND <br />ELEMENTS SHOWN LIGHT MAY NOT NECESSARILY <br />SUPPORT THE HANSON GROUP'S DESIGN. <br />BUILDER IS REQUIRED TO SEND FINAL TRUSS <br />LAYOUT DRAWINGS TO THE HANSON GROUP <br />PRIOR TO CONSTRUCTION FOR VERIFICATION OF <br />LOAD PATHS AND FRAMING SIZES LISTED <br />I hereby certify that this plan, specification or report <br />was prepared by me or under my direct supervision <br />and that I am a duly Licensed Professional Engineer <br />under the laws of the State of Min sota. <br />i <br />Signed: <br />Print Name: TrevorLer <br />Date: 4-26-18 License Number: 45470 <br />3407 Kilmer Lane North <br />Suite 4 <br />Plymouth, MN 55441 <br />Tel 612-708-3572 <br />www.hansongroupmn.com <br />Maxwell Modern <br />Carriage House <br />1020 Tonkawa Rd <br />Orono, MN <br />Project Number: 7.292 <br />Date: April 26, 2018 <br />Sheets: 1 of 1 S1 <br />