Laserfiche WebLink
EXISTING TREE <br />�Z (TYP.) <br />EXISTING POWER POLE <br />(SEE 3/U-2) <br />jL <br />EXISTING OVERHEAD ELECTRICAL LINE <br />�l (SEE 3/U-2) <br />r �L � oHE ❑HE oHE DHE — — DHE �,.� of it — <br />� ) <br />EHE DHE uHu 01 -IE uN� EHE ❑HE o�E <br />C <br />PROPOSED POWER POLE I <br />(SEE 3/U-2) c <br />PROPOSED REROUTING OF EXISTING UNDERGROUND ELECTRICAL <br />(SEE 3/U-2) <br />r, <br />PROPOSED REMOVAL OF EXISTING LIGHT POLE <br />(SEE 3/U-2) LESSEE PREMISES <br />PROPOSED TIMBER EDGING <br />(SEE 5/A-2) <br />PROPOSED 17" X 30" 24" HANDHOLE-, <br />tel- (SEE A-1)33'-0" PROPOSED REMOVAL OF EXISTING TREE <br />®■ <br />s <br />ri V <br />PROPOSED PRIVACY FENCE <br />(SEE A-2) <br />a " <br />— uGE 4 o <br />-3" <br />10 <br />o <br />2 ""E _N I " <br />GE <br />T.O. PIER 1000.0' AMSL a <br />PROPOSED REROUTING OF EXISTING <br />UNDERGROUND ELECTRICAL - - - ILC/DIST. BOX <br />(SEE 3/U-2) 11 4 <br />ICE SHIELD <br />M (TYP.) <br />/ PROPOSED \ <br />BITUMINOUS <br />SURFACE <br />2'-0" 4'-0" 14'-0"A, 8'-0" <br />GATE q lopl GATE <br />6" <br />NOTE: <br />CONTRACTOR TO COORDINATE PUBLIC AND <br />PRIVATE UTILITY LOCATES PRIOR TO <br />CONSTRUCTION START. NOTIFY THE ARCHITECT <br />AND THE VZW CONSTRUCTION ENGINEER <br />IMMEDIATELY OF ANY UTILITY LINE ISSUES. <br />NOTE <br />EQUIPMENT PLATFORM PROVIDED ASSEMBLED <br />WITH GUARD RAILS, ILC (INTEGRATED LOAD CENTER), <br />CANOPY AND LIGHT FIXTURE. CONTRACTOR TO <br />PROVIDE ADEQUATE LIFTING EQUIPMENT FOR PICKING <br />AND SETTING ON FOUNDATION. <br />/ <br />/ / <br />0000 <br />/.000 <br />1 I PROPOSED CLEAN ROCK OVER GEOTEXTILE <br />.� 1 <br />o " . . . 4 <br />+ A-5 <br />oo <br />PROPOSED H -FRAME <br />PROPOSED(SEE 1/U-2) <br />(SEE TH 1)R I J . • PROPOSED RELOCATION OF EXISTING BOULDER <br />AAs - <br />--- AAs <br />PROPOSED (4) BOLLARDS EXISTING UNDERGROUND GAS LINE <br />(TYP•) <br />6'-6" EITUM'LOTS SURFAC= <br />I 1 <br />I A-5 <br />L----------------------------------------------------- -- <br />NORTH <br />ENLARGED SITE PLAN GRAPHIC SCALE <br />1 SCALE: 3/16" = V-0" 0 2'-8• 5'-a <br />J D,q <br />LICENSED <br />ARCHITECT <br />12427 \ <br />I hereby certify that this plan, <br />specification or report was <br />prepared by me or under my direct <br />supervision and that I am a duly <br />registered Architect under <br />the laws of the State of Minnesota. <br />ROBERT J. DAVIS, Reg. No. 12427 <br />r <br />12-20-17 <br />Da <br />DESIGN <br />9973 VALLEY VIEW RD. <br />EDEN PRAIRIE, MN 55344 <br />(952) 903-9299 <br />WWW.DESIGN1EP.COM <br />verizon✓ <br />10801 BUSH LAKE ROAD <br />BLOOMINGTON, MN 55438 <br />(612) 720-0052 <br />I PROJECT I <br />20171566543 <br />LOC. CODE: 443886 <br />MIN <br />TURING <br />NO ORCHARD ROAD <br />ORONO, MN 55391 <br />SHEET CONTENTS: <br />ENLARGED SITE PLAN <br />DRAWN BY: RICKY P. <br />DATE: 11-02-17 <br />CHECKED BY: A.P.S. <br />REV. B 12-20-171 <br />A-3 <br />