Laserfiche WebLink
C)2018 Westwood Professional Services, Inc. <br />- SAN <br />-1020.46 RIM � <br />�i 1014.13 INV NE <br />1016.61 INV W <br />i 1013.91 INV S <br />X ;PST---- <br />{ STO <br />24 INCH- I 1-1021.13 RIM <br />1009.83 INV. E -W <br />-SAN- R, 8 /NCH <br />12 L <br />WA WA AT- <br />I <br />STO STO <br />1020.56 RIM --- <br />1013.69 /NV N <br />1012.91 INV E <br />CBMH 207 <br />RE=1025.50 <br />I E=1021.82 <br />------- - - - <br />I <br />FFRCBMH 106 <br />=1023.90 <br />IE=1020.40 <br />/ <br />_ CONNECT TO EXiS l iNG C SANITARY <br />STUB AND EXTEND 33tF. PRIOR TO <br />CONNECT TO EXISTING ` r-1023.74 RIM CONSTRUCTION, FIELD VERIFY 0� <br />-WM STUB WITH HYDRANT i 1012.74 /NV. E -w r ND INVERT��{{ELEVATION. <br />AND 6" GATE VALVE KLE? ND <br />cans - SAN/ <br />__SAn <br />Wf WA WAT-P-RIOR-TO-STORM SEWER _C�LLSTRUCTION, V Y-3 <br />CLEARANCE AT UTILITY: SSING WITH--Fi9�_ <br />30 /NCH VERIFIED SANITARY STUB IN RT. NOTIFY ENGINEER <br />STOFOR D SIGN SUBMITTAL T6 -CITY -F <br />CT - <br />v <br />57 LF 12" <br />RCP ® 0.58% <br />CBMH 105 <br />RE=1024.00 <br />- IE=1020.07 <br />AREA DRAIN 302 AREA DRAIN 301 PROPOSED BI�ILDING <br />RE=1027.50 RE=1027.50 <br />IE=1023.50 IE=1023.09 Footprint = 39,1976 s.f. <br />FFE=1028.p <br />E=101 7.0 <br />I <br />rte -1022.92 RIM <br />1014.89 INV. W -SE <br />WAT Z <br />7 CONNECT <br />AND6"G <br />Utility Legend <br />EXISTING PROPOSED <br />�-1021.58 RIM <br />ISMIG2.02 INV N <br />H CBMH 104 \ \ <br />T <br />VALVE RE=1023.00 \ <br />1E(;M)=1017.50 \ <br />1 =11 .3-0 \ <br />257 LF 12�►RCP ® 1.007 <br />STO �9T <br />1011.47 /N1 1.009, CBMH01 1 \ <br />\ IE=1016.7 STp <br />\ I <br />\ �2 LF -__15" <br />SANITARY STUB \ RCP ® 1.00 3 <br />IE=1019.00 ��20 1.00% <br />COORDINATE GARAGE DRAIN I <br />SUMP WITH MECHANICAL <br />VERIFY SERVICE SIZE WITH <br />PLUMBING DESIGN PER <br />STATE PLUMBING CODE <br />CBMH <br />PROPERTY LINE <br />- <br />- - - - - - - <br />EASEMENT LINE <br />PVC <br />sro <br />CBMH 210 8 LF 12" RCP <br />CURB AND GUTTER <br />IE(N)=1014.40 <br />SAN <br />- _®_-2�� - - - - ZE=f022.�60--- <br />SANITARY SEWER <br />F= <br />►► ■ <br />STORM SEWER <br />sro <br />STUB FOR ICOURTYARD <br />I <br />WATER MAIN <br />WA T- <br />WA <br />I-..} <br />HYDRANT <br />>< <br />cas- <br />GATE VALVE <br />® <br />hop. <br />FLARED END SECTION <br />�-1021.58 RIM <br />ISMIG2.02 INV N <br />H CBMH 104 \ \ <br />T <br />VALVE RE=1023.00 \ <br />1E(;M)=1017.50 \ <br />1 =11 .3-0 \ <br />257 LF 12�►RCP ® 1.007 <br />STO �9T <br />1011.47 /N1 1.009, CBMH01 1 \ <br />\ IE=1016.7 STp <br />\ I <br />\ �2 LF -__15" <br />SANITARY STUB \ RCP ® 1.00 3 <br />IE=1019.00 ��20 1.00% <br />COORDINATE GARAGE DRAIN I <br />SUMP WITH MECHANICAL <br />VERIFY SERVICE SIZE WITH <br />PLUMBING DESIGN PER <br />STATE PLUMBING CODE <br />6 LF -8 PVC 119 LF -8 PVC <br />49 LF 12" I IES) -1022.44 I 179 LF- PVC <br />PVC I <br />RCP ® 0.5% 18 LF 10" PVC ® 1.0% 11 <br />1024.13 RIM - _ _ 56 LF 12" ;QP ® 0.50% J"► LF 12" RCP ® 0..� ►►97 LF 15" RCP ®►Q50% ►►134 LF 15" RCP 0.50% ►► <br />1012.43 INV E ` - - - - - - - - - - - - - - _ - <br />1012.14 /NV W - <br />- STO <br />G. POH - <br />POH <br />TRENCH IN <br />CBMH <br />12 LF 18 <br />RE=1016.90 <br />STC <br />41 LF,EC PVC 5 10" <br />PVC <br />sro <br />CBMH 210 8 LF 12" RCP <br />"x8" TEE <br />IE(N)=1014.40 <br />- - E- M2T- - - - <br />- _®_-2�� - - - - ZE=f022.�60--- <br />- RE=1026.60 <br />--------® 2.00%- --„----- <br />CBMH 209 <br />101 <br />1. <br />18" <br />STUB FOR ICOURTYARD <br />44 LF 12" <br />LF <br />�"��� _____ CBMH 208 <br />IE=1014014.00 13 <br />RCP ® 0.30% <br />x x x x______ <br />IE=1022.10 <br />1009.65 INV E -W RE=1025.80 <br />cas- <br />DRAINAGE. IE=1021.22 <br />_ <br />GAS <br />48" <br />LOCATION OF EXIST. <br />105 <br />12" HDPE SDR11 WM. <br />01IE=1021.90 <br />-POHe PO o01 <br />POhr' 'OH <br />\ -Y x ---GAS= <br />POH -� <br />LOCATION AND <br />2'x3' <br />COORDINATE WITH <br />200 <br />FES <br />15" <br />----- <br />201 <br />STMH <br />48" <br />R -1642B <br />STMH 205 <br />8" PVC WMPLUMBING <br />LANS. <br />R -1642B <br />203 <br />STMH <br />48" <br />R -1642B <br />204 <br />STMH <br />48" <br />R -1642B <br />RE=1026.90 <br />E=1020.29 <br />STUB CONNECT COURTYARD <br />48" <br />R -1642B <br />206 <br />STMH <br />STMH 20 <br />R -1642B <br />207 <br />CB <br />IE(E, <br />DRAINS TO INTERIOR <br />208 <br />CB <br />2'x3' <br />R-3067 <br />RE=1026.1 <br />CB <br />2'x3' <br />R-3067 <br />210 <br />IE(S)=1022.44 <br />PLUMBING. COORDINATE <br />R-3067 <br />RE=1026.90 <br />STMH 203 <br />IE(SE)=1021.70 <br />R-3067 <br />301 <br />AREA DRAIN <br />WITH MECHANICAL. <br />NYLOPLAST <br />_ <br />RE=1026.50 <br />= <br />19.55- <br />- <br />I�E=1020.22 <br />IE(W)=1020.91--- <br />- -1-024- <br />86------- <br />I <br />. <br />IE(N021.04 - <br />� <br />6 LF -8 PVC 119 LF -8 PVC <br />49 LF 12" I IES) -1022.44 I 179 LF- PVC <br />PVC I <br />RCP ® 0.5% 18 LF 10" PVC ® 1.0% 11 <br />1024.13 RIM - _ _ 56 LF 12" ;QP ® 0.50% J"► LF 12" RCP ® 0..� ►►97 LF 15" RCP ®►Q50% ►►134 LF 15" RCP 0.50% ►► <br />1012.43 INV E ` - - - - - - - - - - - - - - _ - <br />1012.14 /NV W - <br />- STO <br />G. POH - <br />POH <br />TRENCH IN <br />CBMH <br />12 LF 18 <br />RE=1016.90 <br />STC <br />RCP ® 1.177 <br />IE(S)=1014.60 <br />sro <br />CBMH 210 8 LF 12" RCP <br />"x8" TEE <br />IE(N)=1014.40 <br />- - E- M2T- - - - <br />- _®_-2�� - - - - ZE=f022.�60--- <br />- RE=1026.60 <br />--------® 2.00%- --„----- <br />CBMH 209 <br />101 <br />i <br />18" <br />FES -101 <br />44 LF 12" <br />LF <br />�"��� _____ CBMH 208 <br />IE=1014014.00 13 <br />RCP ® 0.30% <br />x x x x______ <br />IE=1022.10 <br />(WITH CLASS III RIPRAP) <br />11020.16 RIM <br />I 1i9Q9.03 /NV W -SE <br />1 <br /><YqT \ <br />CBMH 102 Vo <br />RE=1022.50 1 I :a I <br />IE(NW)=1016.10 I <br />IE(W)=1014.54 <br />IE(E)=1014.14 to <br />I SUMP)=1010.14 <br />23 LF 15" <br />RCP ® 0.70% <br />STMH 201 <br />RE=1025.83 <br />E(SW)=1019.15 <br />❑ IE(E)=1015.16 <br />IE SUMP)=1011.16 <br />67 F 15" <br />RCP 0.60% <br />J II <br />.Q I �I <br />Am <br />(D I I <br />FE -200 <br />� IE5.00 3 I <br />I <br />I <br />8 <br />1-1--8" PVC --A <br />69 L1_ I <br />- STO <br />18 LF 12" <br />RCP @ 11 J� <br />- - - - - - - - - - - - <br />STMH 2O6T <br />CBMH <br />sro sr <br />,� INCH <br />STC <br />RE=1026.30 <br />8 LF 12 RCP 211 <br />RE=1026.60 <br />sro <br />CBMH 210 8 LF 12" RCP <br />"x8" TEE <br />----- <br />- - E- M2T- - - - <br />- _®_-2�� - - - - ZE=f022.�60--- <br />- RE=1026.60 <br />--------® 2.00%- --„----- <br />CBMH 209 <br />101 <br />i <br />18" <br />IE=1022.60 <br />35 LF -6 PVC <br />---RE=a026�------------ <br />�"��� _____ CBMH 208 <br />60" <br />x <br />x x x x______ <br />IE=1022.10 <br />1009.65 INV E -W RE=1025.80 <br />cas- <br />104 <br />_ <br />GAS <br />48" <br />LOCATION OF EXIST. <br />105 <br />12" HDPE SDR11 WM. <br />01IE=1021.90 <br />-POHe PO o01 <br />POhr' 'OH <br />\ -Y x ---GAS= <br />POH -� <br />Westwood <br />Phone (952) 937-5150 7699 Anagram Drive <br />Fax (952) 937-5822 Eden Prairie, MN 55344 <br />Toll Free (888) 937-5150 westwoodps.com <br />Westwood Professional Services, Inc. <br />HYDRANT WITH <br />6" GATE VALVE <br />12 LF 12" <br />RCP ® 2.00% <br />_P0 <br />RAISE STMH RIM AND ADJUST <br />CASTING AS NEEDED TO <br />AVOID PROPOSED CURB <br />RE=1026.34 <br />WAYZATA BOULEVARD WEST (HENNEP/N COUNTY STATE AID HIGHWAY 112) <br />I hereby certify that this plan was prepared by me or under my Revisionm <br />direct supervision and that I am a duly licensed PROFESSIONAL <br />ENGINEER under ffie laws of the State of Minnesota 08/07/17 - City Comments <br />03/20/18 - Final Development Approval Plans <br />05/30/18 - City Comm ents/Stormwater <br />07/11/18 - Watershed Comments <br />Ryan K Bluhm 08/06/18 - City/Watershed Comments <br />08/08/18 -City Comments <br />Dam 08/08/18 _License No. 41257 <br />Ped9ned; PUB <br />Checked: RMB <br />Drawn: SYE <br />Record Drawing by/date: <br />I <br />`1009.24 /NV <br />30 INCH <br />-35 LF 18" <br />RCP ® 1.00% <br />FES -99 <br />IE=1009.00 <br />OCS-100 <br />RE=1015.00 <br />IE(DT)=1009.50 <br />IE(E)=1009.35 <br />�8" GATE VALVE <br />SEWER CASTING <br />CONNECT TO <br />STRUCTURE <br />NUMBER TYPE <br />EXISTING 12" <br />CASTING TYPE <br />PVC WM WITH <br />FES <br />"x8" TEE <br />----- <br />® � <br />I <br />48" <br />R-4342 <br />101 <br />i <br />18" <br />----- <br />i <br />CBMH <br />60" <br />1009.01 INV <br />103 <br />CBMH <br />30 /NCH <br />R-3067 <br />104 <br />-APPROXIMATE <br />48" <br />LOCATION OF EXIST. <br />105 <br />12" HDPE SDR11 WM. <br />48" <br />FIELD VERIFY <br />106 <br />LOCATION AND <br />2'x3' <br />ELEVATION OF WM. <br />POH <br />200 <br />1 <br />Prepared for: Apex HLLC <br />2110 Lyndale Avenue South Suite C <br />Minneapolis, MN 55405 <br />Call 48 Hours before digging: <br />811 or ca11811.com <br />General Utility Notes Common Ground Alliance <br />1. THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION <br />OF EXISTING UTILITIES AS SHOWN ON THESE PLANS ARE BASED ON RECORDS OF THE <br />VARIOUS UTILITY COMPANIES AND LIMITED MEASUREMENTS TAKEN IN THE FIELD. THE <br />INFORMATION SHALL NOT BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR <br />SHALL VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION AND NOTIFY THE OWNER OR <br />ENGINEER OF DISCREPANCIES. <br />2. ALL SANITARY SEWER, STORM SEWER AND WATER MAIN INSTALLATIONS SHALL BE PER <br />MINNESOTA PLUMBING CODE AND IN ACCORDANCE WITH THE CURRENT EDITION OF <br />"STANDARD SPECIFICATIONS FOR WATER MAIN AND SERVICE LINE INSTALLATION AND <br />SANITARY SEWER AND STORM SEWER INSTALLATION" AS PREPARED BY THE CITY <br />ENGINEERS ASSOCIATION OF MINNESOTA. <br />3. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL OBTAIN THE NECESSARY FEDERAL, <br />STATE AND LOCAL PERMITS FOR THE PROPOSED WORK OR VERIFY WITH THE OWNER OR <br />ENGINEER THAT PERMITS HAVE BEEN OBTAINED. PERMIT FEES SHALL BE THE <br />RESPONSIBILITY OF THE CONTRACTOR UNLESS OTHERWISE ARRANGED WITH THE OWNER. <br />4. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION AND <br />DIMENSIONS OF DOORWAYS, RAMPS, TRUCK DOCKS, PRECISE BUILDING DIMENSIONS AND <br />EXACT BUILDING UTILITY CONNECTION LOCATIONS. <br />5. ALL PRIVATE UTILITIES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE SPECIFICATIONS <br />OF THE APPROPRIATE UTILITY COMPANY. THE CONTRACTOR SHALL COORDINATE THE <br />SERVICE LINE CONSTRUCTION WITH THE UTILITY COMPANIES. <br />6. CONTRACTOR SHALL OBTAIN ALL NECESSARY CITY PERMITS FOR UTILITY CONNECTIONS, <br />AND UTILITIES SHALL BE INSPECTED AND APPROVED BY THE CITY. THE CITY SHALL BE <br />NOTIFIED 48 -HOURS PRIOR TO COMMENCING WITH THE UTILITY CONSTRUCTION OR ANY <br />REQUIRED TESTING. CONTRACTOR SHALL NOT OPERATE, INTERFERE WITH, CONNECT ANY <br />PIPE OR HOSE TO, OR TAP ANY WATER MAIN BELONGING TO THE CITY UNLESS DULY <br />AUTHORIZED TO DO SO BY THE CITY. ANY ADVERSE CONSEQUENCES OF SCHEDULED OR <br />UNSCHEDULED DISRUPTIONS OF SERVICE TO THE PUBLIC ARE TO BE THE RESPONSIBILITY <br />OF THE CONTRACTOR. <br />7. WATER MAIN LENGTHS AS SHOWN ARE APPROXIMATE HORIZONTAL LENGTHS. ALLOW FOR <br />ADDITIONAL PIPE WHEN INSTALLING ON SLOPES OR WHEN DEFLECTIONS ARE REQUIRED. <br />THE JOINT DEFLECTIONS SHALL NOT EXCEED THE MAXIMUM RECOMMENDED BY THE PIPE <br />MANUFACTURER OR BY LOCAL GOVERNING SPECIFICATIONS. FITTINGS REQUIRED TO <br />CONSTRUCT WATER MAIN SHALL BE INCLUDED IN WATER MAIN CONSTRUCTION. <br />8. PROVIDE WATER MAIN THRUST RESTRAINTS PER CITY STANDARD REQUIREMENTS. <br />9. A MINIMUM VERTICAL SEPARATION OF 18 INCHES IS REQUIRED AT ALL WATER MAIN <br />CROSSINGS WITH SANITARY SEWER OR STORM SEWER. <br />10. UTILITY SERVICES TYPICALLY TERMINATE 5' OUTSIDE BUILDING WALL UNLESS OTHERWISE <br />SHOWN OR NOTED. <br />11. ALL MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF THE CITY. <br />12. ALL WATER LINES SHALL BE DUCTILE IRON WRAPPED IN POLYETHYLENE, CLASS 52 WITH <br />7.5' MINIMUM COVER. PROVIDE MINIMUM SEPARATION OF 18" FROM SANITARY SEWER & <br />STORM SEWER. INSULATE WATER MAIN IF LESS THAN 7.5' OF COVER. <br />13. INSULATION SHALL BE DOW STYROFOAM HI BRAND 35 OR EQUIVALENT, WITH 4 INCHES OF <br />THICKNESS. <br />14. SANITARY SEWER PIPE OUTSIDE THE BUILDING ENVELOPE SHALL BE POLYVINYL CHLORIDE <br />(PVC) SDR 35 OR 26. SDR 26 IS REQUIRED FOR DEPTHS GREATER THAN 15 FEET. <br />SANITARY SEWER PIPE WITHIN 5 FEET OF BUILDING AND UNDER FOOTINGS, PIPE SHALL BE <br />PVC SCHEDULE 40. <br />15. STORM SEWER PIPE SHALL BE REINFORCED CONCRETE PIPE (CLASS 5 FOR PIPE <br />DIAMETERS 18" AND SMALLER, CLASS 3 FOR PIPE DIAMETERS 21" AND LARGER UNLESS <br />OTHERWISE NOTED) WITH R-4 GASKETS, OR HDPE STORM SEWER PIPE IF ALLOWED BY THE <br />CITY. HDPE STORM PIPE SHALL MEET REQUIREMENTS OF ASTM F2648. PIPE SHALL BE <br />WATER TIGHT ACCORDING TO ASTM D3212 REQUIREMENTS. SEE PLAN FOR LOCATIONS <br />WHERE RCP IS REQUIRED. PVC STORM SEWER PIPE SHALL BE SCHEDULE 40 PIPE. FLARED <br />END SECTIONS SHALL BE RCP WITH TRASH GUARDS & RIP -RAP. <br />16. SIGNS SHOULD BE PROVIDED FOR MANHOLES, GATE VALVES AND FLARED END SECTIONS IN <br />THE AREA EAST OF THE RETAINING WALL TO MARK UTILITIES. <br />STORM <br />SEWER CASTING <br />SCHEDULE <br />STRUCTURE <br />NUMBER TYPE <br />DIA. <br />CASTING TYPE <br />99 <br />FES <br />18" <br />----- <br />100 <br />OCS <br />48" <br />R-4342 <br />101 <br />FES <br />18" <br />----- <br />102 <br />CBMH <br />60" <br />R-3067 <br />103 <br />CBMH <br />48" <br />R-3067 <br />104 <br />CBMH <br />48" <br />R-3067 <br />105 <br />CBMH <br />48" <br />R-3067 <br />106 <br />CB <br />2'x3' <br />R-3067 <br />200 <br />FES <br />15" <br />----- <br />201 <br />STMH <br />48" <br />R -1642B <br />202 <br />STMH <br />48" <br />R -1642B <br />203 <br />STMH <br />48" <br />R -1642B <br />204 <br />STMH <br />48" <br />R -1642B <br />205 <br />STMH <br />48" <br />R -1642B <br />206 <br />STMH <br />48" <br />R -1642B <br />207 <br />CB <br />21x3' <br />R-3067 <br />208 <br />CB <br />2'x3' <br />R-3067 <br />209 <br />CB <br />2'x3' <br />R-3067 <br />210 <br />CB <br />2'x3' <br />R-3067 <br />211 <br />CB <br />2'x3' <br />R-3067 <br />301 <br />AREA DRAIN <br />12" <br />NYLOPLAST <br />302 <br />AREA DRAIN <br />12" <br />NYLOPLAST <br />Orono Senior <br />Housing <br />Orono, Minnesota <br />0' 30' 60' 90' <br />0011740UTPOl.dwg <br />Date: 06/19/17 Sheet: 6 OF 13 <br />Utility Plan <br />