Laserfiche WebLink
SHEET <br />OF <br />DRAWN BY <br />11 <br />DESIGNED BY <br />CHECKED BY <br />NO DATE BY CKD APPR REVISION <br />Date License # <br />Print Name: <br />H <br />: <br />\ <br />P <br />r <br />o <br />j <br />e <br />c <br />t <br />s <br />\ <br />1 <br />1 <br />0 <br />0 <br />0 <br />\ <br />1 <br />1 <br />4 <br />0 <br />0 <br />\ <br />C <br />A <br />D <br />_ <br />B <br />I <br />M <br />\ <br />P <br />l <br />a <br />n <br />\ <br />1 <br />1 <br />4 <br />0 <br />0 <br />_ <br />l <br />n <br />d <br />0 <br />4 <br />. <br />d <br />g <br />n <br />1 <br />0 <br />/ <br />1 <br />8 <br />/ <br />2 <br />0 <br />1 <br />8 <br />1 <br />0 <br />: <br />1 <br />0 <br />: <br />3 <br />2 <br /> <br />A <br />M <br />...\CAD_BIM\Plan\11400_lnd04.dgn CITY PROJECT NO. X <br /> <br /> <br /> <br />X <br />COUNTY PROJECT NO. <br />X <br />STATE PROJECT NO. <br />X <br />X <br />STATE AID PROJECT NO. <br />the laws of the State of Minnesota. <br />that I am a duly Licensed Landscape Architect under <br />was prepared by me or under my direct supervision and <br />I hereby certify that this plan, specification, or report CITY OF ORONO <br />MICHAEL JISCHKE <br />JONATHAN FILLMORE <br />AMY ELIAS <br />MICHAEL JISCHKE <br />COMM. NO. 1140042191 <br />CSAH 112 PHASE 2 LANDSCAPE PLANS <br />INSTALL GRANULAR FILTER <br />INSTALL TILE DRAINAGE <br />FINISHED GRADE. <br />1.EXCAVATE HOLE OR BED TO ALLOW PLACING THE TOP OF ROOT MASS 1"-3" HIGHER THAN <br />LAYER TO ADEQUATELY DRAIN SUBSOIL. <br />2.AUGER 8" DIAMETER HOLES ENTIRELY THROUGH IMPERVIOUS OR POORLY DRAINED HARD PAN SOIL <br />DRAINAGE. <br />3.TEST FOR POSITIVE DRAINAGE. RE-AUGER AN ADDITIONAL 8" IF NECESSARY FOR POSITIVE <br />AND 50% INPLACE SOIL. <br />4.THOUROUGHLY BACKFILL AUGER HOLES WITH A UNIFORM INCORPORATED MIXTURE OF 50% SAND <br />5.COMPLETE PLANTING ACCORDING TO ROOT TYPE. SEE STANDARD PLANTING DETAILS (B). <br />HIGHER THAN FINISHED GRADE. <br />1.EXCAVATE HOLE OR BED TO ALLOW PLACING THE TOP OF THE ROOT MASS 1"-3" <br />2.INSTALL 4" MINIMUM DIAMETER DRAIN TILE DAYLIGHTING AT A LOWER GRADE. <br />3.COMPLETE PLANTING ACCORDING TO ROOT TYPE. SEE STANDARD PLANTING DETAILS (B). <br />INSTALL MINI-BERM <br />NOTE: <br />ENGINEER APPROVAL. <br />WHICH TYPE TO USE ARE DETERMINED BY THE CONTRACTOR, SUBJECT TO <br />1.THE NEED FOR USING PLANTING DETAILS FOR POORLY DRAINED SOILS AND <br />1.EXCAVATE HOLE OR BED 1/4 THE DEPTH OF THE ROOT MASS. <br />2.SET ROOT MASS IN HOLE. <br />TIMES THE BERM HEIGHT. <br />3.CONSTRUCT BERM WITH PLANTING SOIL. EXTEND THE BERM BASE TO A WIDTH OF 3 <br />4.COMPLETE PLANTING ACCORDING ROOT TYPE. SEE STANDARD PLANTING DETAILS (B). <br />OUTWARD-FLARED TOP RIM. <br />PERFORATION AND AN <br />TUBES WITH A LASER LINE <br />TRANSLUCENT POLYPROPYLENE <br />TWIN-WALL, RIGID AND SEMI <br />1.USE SEAMLESS, EXTRUDED, <br />TWISTING. <br />PREVENT DISLODGING OR <br />x 1'' WHITE OAK STAKE TO <br />CABLE-TIES ATTACHED TO A 1'' <br />2.SECURE SHELTER WITH NYLON <br />DISTURBING THE TREE ROOTS. <br />THE SOIL SURFACE WITHOUT <br />TUBE A MINIMUM OF 1'' BELOW <br />3.EMBED THE BOTTOM OF THE <br />NETTING DOWN AS SHOWN. <br />TOP OF THE TUBE. PULL <br />COVER AND SLEEVE OVER THE <br />PHOTODEGRADABLE NETTING <br />4.INSTALL A PLASTIC <br />5' FOR DECIDUOUS TREES <br />8' FOR CONF. TREES <br />CHART ON STANDARD PLANTING DETAILS (B) <br />MINIMUMS FROM THE PLANTING HOLE DIMENSIONS <br />HOLE EXCAVATION WIDTH IN ACCORDANCE WITH <br />PLANTING DETAILS (A) <br />DETAIL SEE STANDARD <br />FOR PLANTING SOIL <br />PLANT SPACING IN MASS BEDS <br />PLANTING DETAIL (B) <br />SEE STANDARD <br />FOR MULCH DETAIL <br />PLANTING DETAIL FOR POORLY DRAINED SOILS <br />8" AUGER <br />HOLES <br />4" DRAIN <br />TILE <br />FOR PLANTING SOIL <br />DETAIL SEE STANDARD <br />PLANTING DETAILS (A) <br />FOR PLANTING SOIL <br />DETAIL SEE STANDARD <br />PLANTING DETAILS (A) <br />FOR PLANTING SOIL <br />DETAIL SEE STANDARD <br />PLANTING DETAILS (A) <br />FOR MULCH DETAIL <br />SEE STANDARD <br />PLANTING DETAIL (B) <br />FOR MULCH DETAIL <br />SEE STANDARD <br />PLANTING DETAIL (B) <br />FOR MULCH DETAIL <br />SEE STANDARD <br />PLANTING DETAIL (B) <br />(MnDOT 2571.3D2 (STEP 8) <br />NOTE: <br />THE UPHILL HALF OF THE WATERING BASIN. <br />1.ON 1:2 SLOPES OR GREATER, DO NOT CONSTRUCT <br />CUT AREA <br />EXISTING GRADE <br />WATER BASIN <br />UPHILL HALF <br />WATER BASIN <br />DOWN HILL HALF <br />PLANTING DETAILS (A) <br />DETAIL SEE STANDARD <br />FOR PLANTING SOIL <br />DETAILS (B) <br />SEE STANDARD PLANTING <br />ROOT TYPE. <br />PLANT ACCORDING TO <br />PLANTING ON SLOPES <br />HOLD WATER IN BASIN. <br />SOIL RIDGE TO <br />PLANTING DETAIL (B) <br />SEE STANDARD <br />FOR MULCH DETAIL <br />SEEDLING TREE SHELTER <br />2 <br />' <br />- <br />0 <br />" <br /> <br />M <br />I N <br />. <br />1 <br />2 <br />" <br /> <br />T <br />O <br /> <br />1 <br />4 <br />" <br />PREVAILING WIND <br />RECESS <br />FORMED TUBE <br />SECURE STAKE IN <br />CABLE-TIE TO <br />(LENGTH VARIES) <br />STAKE <br />TUBE SHELTER <br />PERFORATION <br />LASER LINE <br />NETTING <br />(MnDOT 2571.3I4) <br />RODENT PROTECTION <br />CLOTH). OVERLAP THE CUT END 2". <br />1.FORM A DOUBLE-LAYERED CYLINDER USING 0.25" GRID GALVANIZED WELDED WIRE MESH (HARDWARE <br />CENTER OF THE TREE STEM. <br />2.DRIVE TWO 1" x 1" OPPOSING HEARTWOOD WHITE OAK STAKES INTO THE GROUND, 7" FROM THE <br />OR CABLE-TIES ALONG THE OVERLAP. SPACE APPROXIMATELY 4" ON CENTER ALONG THE OVERLAP. <br />3.SECURE THE MESH CYLINDER TO THE OUTSIDE OF THE STAKES USING EITHER, SCREWS AND WASHERS <br />a.SCREWS SHALL BE ROUND HEAD GALVANIZED 1/8" DIA. x 3/4" LONG WITH WASHERS. <br />OR <br />STRENGTH. <br />b.CABLE-TIES SHALL BE NYLON, AT LEAST 8" LONG AND BETWEEN 75LB TO 120LB TENSILE <br />THE TREE ROOTS. <br />4.EMBED THE LOWER EDGE OF THE MESH CYLINDER 1" BELOW THE SOIL SURFACE WITHOUT DISTURBING <br />THE TOP OF THE CYLINDER. <br />5.CUT EDGES WILL NOT BE PERMITTED AT THE TOP OF THE CYLINDER. STAKE WILL BE FLUSH WITH <br />TRUNK AS SPECIFIED IN MULCH PLACEMENT DETAIL. <br />6.MULCH WITHIN THE CYLINDER SHALL NOT EXCEED 3" DEPTH AND SHALL BE PULLED BACK FROM THE <br />INSTALLATION OF 12" MIN. HEIGHT RODENT GUARDS. <br />7.THE BOTTOM WHORL OF PINE AND LARCH BRANCHES MAY HAVE TO BE REMOVED TO PERMIT <br />8.INSTALL ON ALL DECIDUOUS, PINE AND LARCH TREES, DO NOT PLACE ON SPRUCE TREES. <br />(MnDOT 2571.3I2) <br />WIRE MESH <br />STAKE <br />CONIFEROUS TREES <br />12" MIN. HT. FOR <br />DECIDUOUS TREES <br />24" MIN. HT. FOR <br />STAKING AND GUYING <br />STEEL POST SIZING <br />CALIPER STEEL POST TYPE A B C D <br />4 INCHES <br />LESS THEN <br />7'-0" <br />MIN. <br />3'-0"4'-0"3'-0" <br />INCHES <br />THEN 4 <br />GREATER 10'-0" <br />MIN. <br />4'-0"6'-0"5'-0" <br /> <br />A <br /> <br /> <br />B <br /> <br />C <br /> <br />D <br />SLOPE. <br />REGARDLESS OF GROUND <br />ROOT BALL. DRIVE PLUMB <br />WIRES. PLACE OUTSIDE OF <br />OR DRILLED TO RETAIN GUY <br />TEEL POSTS TO BE NOTCHED1.S <br />BE APPROVED. <br />GUYING SYSTEMS WILL NOT <br />RUBBER HOSE AND WIRE <br />2.REQUESTS TO SUBSTITUTE <br />4.REMOVE WITHIN ONE YEAR. <br />10 ga WIRE. <br />STRAPS. ATTACH WITH <br />THICK AND 1.5" WIDE <br />POLYETHYLENE, 40 MIL. <br />POLYROPYLENE OR <br />16" LONG <br />SEE CHART <br />STEEL POST <br />OR APPROVED EQUAL. <br />POST (MnDOT 3401) <br />CHANNEL STEEL SIGN <br />10', 2.2 LB. FLANGED <br />(MnDOT 2571.3I1) <br />OR APPROVED EQUAL. <br />POST (MnDOT 3403) <br />ROLLED STEEL FENCE <br />1 <br />1 <br />/ <br />4 <br />R <br />O <br />O <br />T <br />M <br />A <br />S <br />S <br /> 15" <br />11STANDARD PLANTING DETAILS <br />BY THE ENGINEER. <br />PROBLEM, OR AS DIRECTED <br />WIND CONDITIONS ARE A <br />WHERE VANDALISM, SOIL, OR <br />TREES IN A PLUMB CONDITION <br />OR NECESSARY TO MAINTAIN <br />REQUIRED UNLESS SPECIFIED <br />3. TREE STAKING IS NOT