EDITION 1210-1212 M <br /> sleeping rooms are on an upper level,the detector shall be placed at the center of <br /> the ceiling directly above the stairway.All detectors shall be located in accordance <br /> with approved manufacturer's instructions. When actuated, the detector shall <br /> provide an alarm in the dwelling unit or guest room. <br /> When the valuation of an addition or repair to a Group R,Division 3 Occupancy <br /> exceeds$1,000.00,or when one or more sleeping rooms are added or created in <br /> existing Group R,Division 3 Occupancies,the entire building shall be provided <br /> with smoke detectors located as required for new Group R,Division 3 Occupan- <br /> cies. <br /> % In new construction, required smoke detectors shall receive their primary <br /> power from the building wiring when such wiring is served from a commercial <br /> source.Wiring shall be permanent and without a disconnecting switch other than <br /> those required for overcurrent protection.Smoke detectors may be battery oper- <br /> ated when installed in existing buildings, or in buildings without commercial - - — <br /> power,or in buildings which undergo alterations,repairs or additions regulated by <br /> the second paragraph of this section. <br /> A smoke detector shall be installed in the basement of dwelling units having a i <br /> stairway which opens from the basement into the dwelling.Such detector shall be <br /> connected to a sounding device or other detector to provide an alarm which will be <br /> audible in the sleeping area. <br /> (b)Sprinkler and Standpipe Systems.When required by other provisions of <br /> this code,automatic sprinkler systems and standpipes shall be installed as speci- <br /> fied in Chapter 38. <br /> Heating <br /> Sec.1211.Every dwelling unit and guest room shall be provided with heating <br /> facilities capable of maintaining a room temperature of 70°E at a point 3 feet <br /> above the floor in all habitable rooms. <br /> Special Hazards <br /> Sec.1212.Chimneys and heating apparatus shall conform to the requirements <br /> of Chapter 37 and the Mechanical Code. <br /> The storage and handling of gasoline,fuel oil or other flammable liquids in <br /> Division 1 Occupancies shall be in accordance with the Fire Code. <br /> In Division 1 Occupancies,doors leading into rooms in which Class I flamma- <br /> ble liquids are stored or used shall be protected by a fire assembly having a one- <br /> hour fire-protection rating.Such fire assembly shall be self-closing and shall be <br /> posted with a sign on each side of the door in 1-inch block letters stating:FIRE <br /> DOOR—KEEP CLOSED. <br /> Every room containing a boiler,central heating plant or hot-water supply boiler <br /> in Division 1 Occupancies shall be separated from the rest of the building by not <br /> less than a one-hour fire-resistive occupancy separation. <br /> EXCEPTION:A separation shall not be required for such rooms with equipment <br /> serving only one dwelling unit. <br /> 75 <br />