My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
re: hazardous bldg info
Orono
>
Property Files
>
Street Address
>
T
>
Tonkawa Road
>
0525 Tonkawa Road - 06-117-23-41-0098
>
Correspondence
>
re: hazardous bldg info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:15:33 PM
Creation date
5/21/2019 1:28:19 PM
Metadata
Fields
Template:
x Address Old
Address
0525 Tonkawa Rd
Document Type
Correspondence
PIN
0611723410098
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EDITION 1210-1212 M <br /> sleeping rooms are on an upper level,the detector shall be placed at the center of <br /> the ceiling directly above the stairway.All detectors shall be located in accordance <br /> with approved manufacturer's instructions. When actuated, the detector shall <br /> provide an alarm in the dwelling unit or guest room. <br /> When the valuation of an addition or repair to a Group R,Division 3 Occupancy <br /> exceeds$1,000.00,or when one or more sleeping rooms are added or created in <br /> existing Group R,Division 3 Occupancies,the entire building shall be provided <br /> with smoke detectors located as required for new Group R,Division 3 Occupan- <br /> cies. <br /> % In new construction, required smoke detectors shall receive their primary <br /> power from the building wiring when such wiring is served from a commercial <br /> source.Wiring shall be permanent and without a disconnecting switch other than <br /> those required for overcurrent protection.Smoke detectors may be battery oper- <br /> ated when installed in existing buildings, or in buildings without commercial - - — <br /> power,or in buildings which undergo alterations,repairs or additions regulated by <br /> the second paragraph of this section. <br /> A smoke detector shall be installed in the basement of dwelling units having a i <br /> stairway which opens from the basement into the dwelling.Such detector shall be <br /> connected to a sounding device or other detector to provide an alarm which will be <br /> audible in the sleeping area. <br /> (b)Sprinkler and Standpipe Systems.When required by other provisions of <br /> this code,automatic sprinkler systems and standpipes shall be installed as speci- <br /> fied in Chapter 38. <br /> Heating <br /> Sec.1211.Every dwelling unit and guest room shall be provided with heating <br /> facilities capable of maintaining a room temperature of 70°E at a point 3 feet <br /> above the floor in all habitable rooms. <br /> Special Hazards <br /> Sec.1212.Chimneys and heating apparatus shall conform to the requirements <br /> of Chapter 37 and the Mechanical Code. <br /> The storage and handling of gasoline,fuel oil or other flammable liquids in <br /> Division 1 Occupancies shall be in accordance with the Fire Code. <br /> In Division 1 Occupancies,doors leading into rooms in which Class I flamma- <br /> ble liquids are stored or used shall be protected by a fire assembly having a one- <br /> hour fire-protection rating.Such fire assembly shall be self-closing and shall be <br /> posted with a sign on each side of the door in 1-inch block letters stating:FIRE <br /> DOOR—KEEP CLOSED. <br /> Every room containing a boiler,central heating plant or hot-water supply boiler <br /> in Division 1 Occupancies shall be separated from the rest of the building by not <br /> less than a one-hour fire-resistive occupancy separation. <br /> EXCEPTION:A separation shall not be required for such rooms with equipment <br /> serving only one dwelling unit. <br /> 75 <br />
The URL can be used to link to this page
Your browser does not support the video tag.