200A MTS BREAKER PANEL <br />(by Reliable Electric) <br />50A 120/240 10 <br />MALE RECEPTICAL -� <br />(by Reliable Electric) <br />50,0 KVA <br />TRANSFOMER <br />20V X 30H <br />X 20D <br />(by Reliable Electric) <br />NORTH <br />136' <br />100A BREAKER <br />(by Reliable Electric) <br />COMPUTER CONSOLE <br />CABINET <br />(by Reliable Electric) <br />CT CABINET (1200A) <br />61 L-*, n, -BREAKER (1200A) - <br />- _(by Reliable Electric) <br />77' — <br />AC 120V <br />VAP❑RTIGHT <br />LIGHTS <br />20' 14' 38' <br />t <br />6" <br />20' 8 ' 9_ <br />— eu sre� <br />4 <br />40j' 3/4' o <br />rr KITII ITT <br />I✓ U <br />0 <br />er, <br />0 <br />272' ­­u.,v <br />LENGTH <br />STEPS GENERATOR _I_ 35' <br />MANUAL FIRE <br />PULL STATION <br />PHONE FIRE SUPP RESSION <br />0 F_ -74, <br />GFI —# <br />SWITCH <br />OFF ❑F FUEL T1 NK 0 <br />0 THE FLOOR o VENTS <br />• 1 � I <br />I I <br />W H <br />l <br />+ <br />l <br />I <br />La <br />+v� p Lo <br />l <br />• • <br />'- N <br />1 <br />r <br />I I <br />mt sus <br />k-3 38' <br />. <br />GFI <br />0" <br />f <br />FIRE SUPPRESSION 12' -' I <br />STROBE LIGHT 24 36' WEST <br />NCL❑SUR <br />ROOF 1 1' NPT PORT FOR FILTER RETURN <br />14 GAUGE GALVANNEALED WELDED CONSTRUCTION WITH <br />14 GAUGE GALVANNEALED ROOF BEAMS MOTORIZED DAMPER <br />WALLS 67'W x 100'H <br />4 INCH, 14 GAUGE GALVANNEALED WELDED CONSTRUCTION <br />6 3/4 INCH FIBERGLASS INSULATION AND 22 GA, PERFORATED SOUND ATTENUATOR <br />GALVANIZED LINER W/FIXED BLADE LOUVER <br />DOORS 67'W x 100'H x 42'D <br />4 INCH, 14 GAUGE GALVANNEALED WELDED CONSTRUCTION WITH <br />STANDARD HANDLE #73 -NS (padlock by others) AND 2 -POINT <br />ROD LATCH WITH INSIDE ❑VER -RIDE <br />DOOR BUMPERS AND DOOR HOLD -BACKS <br />MOTORIZED INTAKE AND EXHAUST DAMPERS MOUNTED ON INTERIOR <br />(power open/spring close), thermostat controlled to open <br />on temperature rise <br />SOUND ATTENUATOR ON INTAKE AND EXHAUST AIR WITH FIXED LOUVERS <br />AND BIRDSCREEN <br />RECESSED FUEL FILL WITH 10 GALLON FUEL CONTAINMENT <br />ASE FABRICATI❑N <br />4 INCH x 4 INCH SQUARE TUBE <br />FUEL TANK (2000 GAL, UL LISTED) - AS REQUIRED <br />TANK INCLUDES: ENGINE SUCTION AND RETURN PORTS, SPARE PORT, FUEL <br />FILL PORT, EMERGENCY VENT, NORMAL VENT, RUPTURE BASIN VENT, <br />MECHANICAL GAUGE, LOW LEVEL ALARM, 75% FULL, 90% FULL, 95% FULL, <br />ALARMS, RUPTURE BASIN ALARM, DRAIN PORTS AND (1) ELECTRICAL <br />STUB -UP AREAS, PORTS FOR FUEL FILTER SYSTEM BY CUSTOMER <br />RUPP TO SUPPLY AND INSTALL <br />EXHAUST HARDWARE <br />TO INCLUDE: SILENCER SADDLE, RAIN CAP, RAIN GUARD, ANY <br />ADDITIONAL PIPING REQUIRED, ELBOW, NGB KITS AND GASKETS, <br />INSULATI❑N BLANKET <br />RUBBER FLOOR MATTING ON FLOOR WALKWAY AREAS <br />OIL AND WATER DRAINS REMOTE TO EXTERIOR <br />FUMES DISPOSAL CANISTER <br />CUSTOMER TO SUPPLY RUPP TO INSTALL <br />GENERATOR, ❑NAN 500 DEED <br />MOUNT AND PLUMB <br />EXHAUST SILENCER: (l) ❑NAN #155-2342-02, (l) FLEX: ❑NAN <br />#155-2572-07 AND (1) ONAN REDUCING COMPANION FLANGE #505-1218 <br />MOUNT AND ALIGN ON ROOF (May be removed for shipping) <br />ISOLATORS: (6) KORFUND #LKD-56 <br />MOUNT BETWEEN GENSET AND FUEL TANK <br />GENERATOR BATTERIES <br />(2) 430OW WATER JACKET HEATERS - PREINSTALLED (Wired by RUPP) <br />CUSTOMER TO SUPPLY RUPP TO INSTALL AND WIRE <br />BATTERY CHARGER <br />1200A CT CABINET <br />LOAD CENTER 200A MTS <br />50A WEATHER PROOF MALE RECEPTICAL Con exterior wall behind toad center) <br />COMPUTER CONSOLE CABINET <br />100A CIRCUIT BREAKER W/ ENCLOSURE 490V 10 <br />TRANSFORMER 50,OKVA 480V 10 TO 120/240V <br />UPP TO SUPPLY INSTALL AND WIRE <br />(8) 200W LIGHTS, (2) SWITCH/GFI <br />DUPLEX RECEPTACLES IN INTERIOR, 5KW ROOM HEATER 240V 10, <br />(8) DAMPER MOTORS WITH CONTROL, (4) 4'x4' WEATHERPROOF BOXES <br />ON EXTERIOR (lights supplied and Installed by Reliable Electric) AND <br />(4) WEATHERPROOF BOXES AND COVERS W/GFI RECEPTACLES ON EXTERI❑R <br />FIRE SUPPRESSION SYSTEM - FENWEL-FM 200 GAS WITH HEAT <br />DETECTORS, MANUAL PULL STATION AND AN ALARM STROBE/HORN <br />LOW FUEL LEVEL ALARM: TO GENSET CUSTOMER CONNECTION BOX <br />RUPTURE BASIN ALARM, TO GENSET CUSTOMER CONNECTION BOX <br />DOOR ACTIVATED SWITCH: IN RECESSED FUEL FILL BOX <br />75% FULL FUEL ALARM+ TO RECESSED FUEL FILL BOX <br />90% FULL FUEL ALARM: TO RECESSED FUEL FILL BOX <br />95% FULL FUEL ALARM: TO RECESSED FUEL FILL BOX <br />GFI DUPLEX RECEPTACLE° <br />- W/WEATHERPRO❑F BOX & COVER----/ ROOF SPLICE ROOF SPLICE <br />(4 pin 2. > Cb PI') --.- - <br />i4'x4; WEATHERPROOF BOX 85j' Z85 ' <br />C"places) (by RUPP) <br />FOR EXTERIOR LIGHTS d `cu At <br />' <br />(supplied & InstaUed by Reliable Electric) N U (n o <br />CU <br />FIRE SUPPRESSION STROBE LIGHT 138'—l1 m m L n m n m m m m m m m I) — 138' <br />I'II III II III 111 I'll III I11 I I III Irlx---134' <br />I I III 111 III 111 II 111 III 111 UI III 1 1 III III I11 III I I <br />1" 134 NPT PORT W/ DIP TUBE FOR FILTER SUCTION 1 I 111 nl 1 u III n 111 In 111 nl nl I I m n 1 III I11 --1251" <br />I I III III 111 111 II I11 111 111 111 111 I I 111 III 111 II I I 2 <br />RADIAT❑R DUCT MOTORIZED DAMPER i i iii iii iii iii ii 111 111 111 III 111 11 111 111 Il�g" `--118' <br />III III III III III I I 111 111 II <br />ADAPTOR 67'W x 100'H 1 I III Ifl 111 III II 111 III 111 III III f I11 III II 04'III II I I <br />I I III III III I11 II IIf III 111 111 111 I I lIl 111 Ifl III I I <br />I I I11 III III III II III III III III I11 11 III fll fll 111 I I <br />I t 111 III III Ifl II III III III III III I I III II( III 111 I 1 <br />I I III III III III •I I11 I11 III III I1 Ilt 111 III Ifl I I <br />11 m m to m �15 III nl nl nl 11 m nl nl m II <br />I 1 I 111 III III Ifl 11 III I III III 111 11 III III III Ifl I 1 <br />SOUND ATTENUATOR I I 111 III 111 fll II 111 I III III 111 11 III III III 111 I 1 <br />I I III III III III 11 III 11 III III III 11 III III III III t I <br />W/FIXED BLADE LOUVER I I In m In m u III nl nl In In 11 ul nl nl ul I1 <br />67'W x 100'H x 42'D I I III I11 111 111 tl 111 III III 111 III III 111 III 1 1 <br />I I III III III II( IC---- --7u In nl lU � I nl nl m lu I 1 <br />� I I III III III III I 11 III III III 11 III 111 III 111 t l <br />I I III III III III II III I11 I11 fll III 111 III III III 1 1 <br />563• I11 I11 III I11 1 I Ill III III III I 1 <br />I F I I III III III III II III III III III 11 III III III 111 11 <br />Z I I III III III III II III I11 I11 III 111 Ifl 111 111 III I I <br />D I I III III III III I --- - 11 111 I11 III 11 III III III 111 I 1 <br />Q' I I 111 III III I11 II----m---�11 III I11 III I t III III 111 III I I <br />I � I I III Ilt 111 111 II 111 (11 III 111 111 11 I11 111 111 111 I I <br />I I If1 III fll III II 111 III fli III III t 1 III III 111 111 I I <br />36'-- -� 1 1 III III III I11 II III III III I11 111 f l Ifl III I11 III I I <br />1 I III III III I11 II III III 111 III III I I III 111 111 III I I <br />1 i m m in In n ul iii iii ... - ;; H! nl n1 HI 1 <br />Iu <br />-,J 4+ <br />01 <br />BATTERY 2' FUEL FILL <br />CHARGER <br />THERMOSTAT MECH. FUEL GAUGE d <br />DAMPER OVERRIDE RECESSED FUEL FILL BOX as <br />5KW HEATER 10 GAL. CONTAINMENT <br />PULLING OF WIRES & PIPING <br />FOR EMER. EXIT LIGHT BY RUPP <br />(2) LIGHTS SUPPLIED <br />BY RELIABLE ELECTRIC ENCLOSURE TOP VIEW <br />DC LIGHTS <br />(PIPING BY RUPP) <br />(LIGHTS & WIRING BY RELIABLE ELECTRIC) <br />—10, <br />• <br />3# <br />1/2'-13x2 1/2' 1/2' STEEL <br />MTG. STUDS PLATE <br />ISOLATOR MTG, PLATE <br />KORFUND #LKD-56 <br />(6 places) <br />TRANSFORMER <br />AND BASE <br />ISCELLANE❑US <br />RUPP TO SOPPY IBC CERTIFICATION <br />RUPP TO PREP, PRIME AND PAINT ONE COLOR: MATCH SW40241 ENVIR❑ GREEN <br />%0 61 al 117 00 <br />n Cn al a oa <br />at a! N IU -+ <br />LIFTING EYE <br />MTG. POINTS <br />(6 places) <br />I <br />l <br />l <br />l <br />l <br />f <br />l <br />l I <br />'- N <br />o <br />.- I(U <br />i0 <br />0" <br />(U <br />to <br />M C% <br />4' <br />0' <br />H <br />Z <br />0 <br />W <br />U_ <br />CITY OF ORONO <br />ROOF TOP VIEW BUILDING PF (IIT' PLAN R1LVi'EN <br />INSPECTOR <br />DATE t2'7.m •`1- <br />fr <br />P iOVEC AS &uCl ' I -TED <br />❑ PROVED W i -Ii <br />FUEL SUCTI❑N, FUELPa <br />Ts <br />RETURN, SPARE KEEP THIS PLAN SET ON SET E r"aC ALL Tiiv; 8 <br />LOW FUEL, 75% FULL, <br />90% FULL, 100% FULL <br />ALARMS <br />NORMAL VENT & <br />CU <br />,� EMERGENCY VENT <br />CIL! 0r, In Cl) 0 CD oN <br />CU a1 CU . , o <br />136' <br />124j" EMERGENCY VENT <br />�.- NORMAL VENT <br />117' �� FILTER SUCTION <br />113` <br />964' FUEL SUCTI❑N <br />922" FUEL RETURN, LOW FUEL, <br />90' 75% FULL, 90% FULL, <br />87�' 95% FULL ALARMS <br />SPARE <br />z <br />0 <br />9'--, MECH. FUEL GAUGE, <br />0' 2" FUEL FILL <br />♦ • ♦ a ♦ a ♦ • ♦ ♦ ♦ ♦o <br />r- t0 n d' oti tD CV) oti In <br />al al al a1 ' al al <br />L 2' FUEL FILL <br />FUEL TANK TOP VIEW \—MECH, FUEL GAUGE <br />ONE RUPP PLAZA, 3700 REST PRESERVE BOULEVARD DRAWN.' SC SHEET 2 OF 3 <br />RUPP INDUSTRIES, INC. BURNSVILLLE, MN 55337-7746 PHONE: (612) 707-5216 CHILD: SCALE: <br />. 1=45 <br />CUSTOMER: CUSTOMER P.0 NO.: DATE: REVISION RECORD RUTH. DB <br />CUMMINS NORTH CENTRAL JOB NAME: <br />STUBS BAY - MINNETIINKA 07/07 REDESIGN DAH <br />T FIE N.. 08/18/99 RECONFIGURED GENSET DAH <br />L 90273-02 <br />FUEL TANK FOR AN ❑NAN 500 DEED GENERATOR DWC. NO.: 500-3070 10/26/99 CUSTOMER REDESIGN L.�/ DAH <br />THIS DOCUMENT IS ONLY G>I♦iDITIOMALLY ISSUED MID NEIiM CONFERS DATE. DWG. NO.: 10/29/99 CUSTOMER REDESIGN LEY I'm <br />OR TRANSFERS ANY RItiiT Tn USE: THE SU"IN MATTER OF THE DOCUMENT ��'jj <br />NOR ARIGHT m REPRMUCE THIS BDcuMEMT EXCEPT PER MANUFACTURE BY 6— G— 9 9 <br />NY 90273-02 <br />VENDORS FB2 RUPP IND. NO RIGHT TO REPS THIS DOCUMENT IS GWITEOI 11/09/99 CUSTOMER REDESIGN LCW/ D <br />LESS (jH_! <br />UNWITH VOTTEN PQiMISS39�1 FR13M RUPP TMIUSTYMIE$, W_.irrP drat <br />p P <br />Den Yl <br />