Laserfiche WebLink
09. 03. 92 1 1 : 45-AM KSRUCE SCHMIT"T & ASSC 1=103 <br /> "wi <br /> WOOD FRAME/SIDING ATINSULATION <br /> EXTERIOR AIR FILM 0.17 <br /> SIDING 0.81 <br /> TYVEK 0.06 <br /> SHEATHING 0.83 <br /> INSULATION 19.00 <br /> GYPSUM BOARD 0.57 <br /> INTERIOR AIR FILM 0.88 <br /> TOYAL R 21.92;'U'= 0.0456 <br /> RIM AT SIDING <br /> EXTERIOR AIR FILM 0,17 <br /> SIDING 0.81 <br /> TYVEK 0.06 <br /> SHEATHING o.s3 <br /> RIM JOIST 1.88 <br /> BATT INSULATION 25.00 <br /> INTERIOR AIR FILM 0.68 <br /> TOTAL R 24.2.? "u"m 0•0342 <br /> AT ATTIC <br /> EXTERIOR AIR FILM 0.17 <br /> RIM JOIST 1.88 <br /> BATT INSULATION 26.00 <br /> INTERIOR AIR FILM 0.0 <br /> TOTAL R 27.73;*LP- 0A361 <br /> EXTERIOR AIR FILM 0.17 <br /> 112'PLYWOOD SHEATHING 0.6 <br /> INSULATION 38.00 <br /> 5/8"PLYWOOD SUBFLOOR 0.78 <br /> INTEF40R AIR FILM 0.92 <br /> TOTAL R 40.50;V-- 0.0247 <br /> NET AREAS <br /> FLAT CEILING 540.0 <br /> AREA 640.0 SQ.FT. <br /> LESS OPENINGS NONE SQ.FT. _ <br /> NET 640;0 SQ.FT. <br /> AT CONCRETE BLOCKIFURRING NO OPENINGS <br /> WALL AREA 97.0 SQ.FT. <br /> LESS OPENINGS o.o SQ,FT. <br /> NEI' 97.0 SO-FT <br /> BRUCE W.SCHMITT&ASSOCOCIATES,PA. PAGE 3 <br />