My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Report/hazardous bld materials inspection
Orono
>
Property Files
>
Street Address
>
T
>
Togo Road
>
3655 Togo Road - 17-117-23-31-0036
>
Misc
>
Report/hazardous bld materials inspection
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:36:17 PM
Creation date
4/26/2019 2:08:27 PM
Metadata
Fields
Template:
x Address Old
House Number
3655
Street Name
Togo
Street Type
Road
Address
3655 Togo Road
Document Type
Misc
PIN
1711723310036
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
View images
View plain text
BRAUN Braun Intertee Corporation Phone 952 995.2000 <br /> 1001. -AcmcsF e Avenue S Fox: 952.995.2020 <br /> INTERTEC Mlrieopo;s.MN 55438 Web: bov +erec.com <br /> A. Scope of Services <br /> The scope of our services was limited to: <br /> Visually examining accessible areas and identifying the locations of suspect asbestos- <br /> containing building materials(ACBM),lead,poly-chlorinated biphenyl's(PCB), <br /> mercury,and other miscellaneous hazardous materials. <br /> • Collecting and analyzing representative bulk samples of materials suspected of <br /> containing asbestos. Examples of materials to be collected for analysis include,but are <br /> not limited to:floor tile,linoleum flooring,wall and ceiling plaster,suspended and <br /> acoustical ceiling tile,sheetrock,thermal system insulation,textured ceiling material and <br /> fireproofing. <br /> • Documenting ACBM current conditions and quantities. <br /> • Conducting limited lead-based paint testing of painted surfaces suspected of containing <br /> lead(if applicable). Testing will be accomplished using a Niton X-ray fluorescence <br /> (XRF)spectrum analyzer. <br /> • Generating a final report documenting the sample locations,analysis results,ACBM <br /> quantities,conditions,and recommendations. <br /> B. Site Description <br /> The subject of this hazardous building materials inspection was the building,located at 3655 Togo <br /> Road in Navarre,Minnesota. It is a one-story structure with a basement level comprising <br /> approximately 2,000 square feet. The original date of construction is unknown,but is estimated to be <br /> in the 1970s. <br /> C. Results <br /> C.I. Asbestos <br /> C.1.1. Asbestos-Containing Materials <br /> Ten(10)bulk samples from 6 homogenous materials were collected on May 16,2005,and submitted <br /> to our laboratory for analysis. No asbestos was detected in any of the samples. <br /> C.1.2. Non-Asbestos-Containing Materials <br /> The following is a summary of building materials found to contain no asbestos or materials that <br /> contain one percent or less asbestos(non-asbestos-containing materials by regulatory definition). <br /> • Ceiling texture <br /> • 2-foot by 4-foot ceiling panel <br /> • Wall texture <br /> • Sheetrock and associated joint compound <br /> • Linoleum flooring and adhesive <br /> • Asphalt roof shingles and tar paper <br /> -- --+ Providing engineering and environmental solutions since 1957 <br />