Laserfiche WebLink
Page 1 Residential Heat Loss and Heat Gain Calculation 5/9/2012 <br /> In accordance with ACCA Manual J <br /> Report Prepared By: <br /> A&M Mechanical LLC <br /> For: Roman <br /> 645 Togo <br /> Orono, Minnesota 55356 <br /> Design Conditions: St.Paul <br /> Indoor: Outdoor: <br /> Summer temperature: 73 Summer temperature: 105 <br /> Winter temperature: 72 Winter temperature: -25 <br /> Relative humidity: 55 Summer grains of moisture: 100 <br /> Daily temperature range: High <br /> Building Component Sensible Latent Total Total <br /> Gain Gain Heat Gain Heat Loss <br /> (BTUH) (BTUH) (BTUH) (BTUH) <br /> Duct 2,139 0 2,139 5,501 <br /> Floors 0 0 0 2,428 <br /> Walls 688 0 688 3,128 <br /> Ceilings 1,223 0 1,223 2,327 <br /> People 900 690 1,590 0 <br /> Fireplaces 0 0 0 0 <br /> Misc 0 0 0 0 <br /> Windows 7,200 0 7,200 23,OJ7 <br /> Doors 523 0 523 1,659 <br /> Glassdoors 1,299 0 1,299 3,073 <br /> Skylights 0 0 0 0 <br /> Infiltration 2,203 1,404 3,607 10,016 <br /> Whole House 16,175 2,084 18,269 51,169 <br /> ( 1.5 tons) <br /> HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101 <br /> load s we eaflmetw o*adud bads nay vmy due to wewwr and cwftucW . <br />