Laserfiche WebLink
Manufacturer : SCHERER BROS . U factor : 0 .32 <br /> State approved: YES <br /> Type Height x Length x Number = Total <br /> ( inches ) ( Inches ) of glass SgFt <br /> units <br /> CASEMENT 48 20 9 60 <br /> CASEMENT 60 20 52 433 .33 <br /> CASEMENT 48 24 9 72 <br /> CASEMENT 60 26 3 32 .5 <br /> CASEMENT 48 28 2 18 .67 <br /> CASEMENT 60 28 2 23 .33 <br /> FIXED 12 20 4 6 .67 <br /> FIXED 12 28 2 4 .67 <br /> FIXED 72 66 1 33 <br /> 0 0 0 0 <br /> 0 0 0 0 <br /> 0 0 0 0 <br /> 0 0 0 0 <br /> 7 . Window glass area (SgFt ) = 684 . 17 <br /> Type Height x Length x Number = Total <br /> ( feet ) ( feet ) units SgFt <br /> 8 . Patio Door : 6 .85 3 5 102 .75 <br /> 9 . Atrium: 0 0 0 0 <br /> 10 . Fireplace area <br /> Width: 6 Height: 5 <br /> Total Sq Ft = 30 <br /> 11 . Exposed Foundation <br /> Height area A: 0 .67 Perimeter area A: 223 <br /> Sq Ft area A = 149 .41 <br /> Exposed Foundation <br /> Height area B: 0 Perimeter area B: O <br /> Sq Ft area B = 0 <br /> 12 . SgFt U factor U x A <br /> Gross wall area 5305 .32 <br /> minus <br /> Window area 684 .17 0 .32 218 .93 <br /> Patio door area 102 .75 0 .47 48 .29 <br /> Atrium area 0 0 0 <br /> Rim joist area 263 0 .041 10 .78 <br /> Door area 69 .8 0 . 14 9 .77 <br /> Fireplace area 30 0 .76 22 .8 <br /> Exposed Found . 149.41 0 .076 11 .36 <br /> * Framing area 530.532 0 .095 50 .4 <br /> equals <br /> Totals for net wall : 3475.658 0 .043 149 .45 <br />