Manufacturer : ANDERSEN U factor : 0 . 32 <br /> State approved : YES <br /> Type Height x Length x Number = Total <br /> ( inches ) ( Inches ) of glass SgFt <br /> units <br /> CASEMENTS 36 24 13 78 <br /> CASEMENTS 60 24 12 120 <br /> CASEMENTS 48 24 8 64 <br /> CASEMENTS 54 2el 11 99 <br /> CASEMENTS 60 16 4 26 .67 <br /> CASEMENTS 60 0 2 25 <br /> FIXED 192 60 1 80 <br /> FIXED 54 42 2 31 .5 <br /> FIXED S4 36 2 27 <br /> TRANSOMS 12 42 2 7 <br /> TRANSOMS 12 24 12 24 <br /> ARCHTOP 54 54 1 20 .25 <br /> ARCHTOP 20 66 1 9 . 166666 <br /> 7 . Window glass area ( SgFt ) = 611 .5866 <br /> Type Height x Length x Number Total <br /> ( feet ) ( feef ) units SgFt <br /> 8 . Patio Door : 0 u 0 0 <br /> 9 . Atrium : 6 .85 3 2 41 . 1 <br /> 10 . Fireplace area <br /> Width : 0 Height : 0 <br /> Total Sq Ft = 0 <br /> 11 . Exposed Foundation <br /> Height area A: 0 .72 Perimeter area A: 241 <br /> Sq Ft area A = 173 .52 <br /> Exposed Foundation <br /> Height area B : 0 Perimeter area B: 0 <br /> 5q Ft area B 0 <br /> 12 . SgFt U factor U x A <br /> Gross wall area 4911 .88 <br /> minus <br /> Window area 611 . 58666667 0 . 32 195 .71 <br /> Patio door area 0 0 0 <br /> Atrium area 41 . 1 0 .44 18 .08 <br /> Rim joist area 355 .5 0 .041 14 .58 <br /> Door area 71 .6 0 . 14 10 .02 <br /> Fireplace area 0 0 0 <br /> Exposed Found . 173 .52 0 .076 13 . 19 <br /> Framing area 491 . 188 0 .095 46 .66 <br /> equals <br /> Totals for net wall : 3167 .3853333 0 .043 136 .2 <br />