Laserfiche WebLink
CITY of ORONO <br /> Municipal Offim <br /> Street Address: qSa-a►49-y 6o O Mailing Address: <br /> O 2750 Kelley Parkway P.O. Sax 66 <br /> Orono, MN 55356 Crystal Say, MN 55323-0066 <br /> To Current Owner: Address: SlD T CkLn-� <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> -SYSTEM CONFORMITY (1-3): <br /> 1 `CODE SYSTEM"An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requireooent for systems installed 1996 or earlier,and <br /> which is not failing or an imunne nt threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISIS;an ISTS located within a designated 100-year flood plain,any ISIS which may <br /> or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISIS with less than dare feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-7): <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 60 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped, )• <br /> Make sure septic tanks are pumped t hroush manhole and not throuth white inspection pipes. This allows for the proper <br /> clmnin¢. Keep water softner and iron filter discbaree out of septic system to prolong life of drainfield. Ask pumper to test <br /> alarm float to verify alarm is still workine in your house. The alarm warns owner that septan_e is about to backup into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDITION 8-10 : <br /> 8 Dtainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not c ntical yet. <br /> 10 Diainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: <br /> a--0 OS_ - <br /> Date of Inspection Matt Bolterman- Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does <br /> not guarantee or catify that an existing system will continue to fimcdon properly, but is merely an opinion of the adequacy of the system under current <br /> conditions based on the available information. <br />