1996-008472 - new septic
Orono
>
Property Files
>
Street Address
>
T
>
Tanglewood Road
>
1520 Tanglewood Road - 26-118-23-32-0010
>
Septic
>
1996-008472 - new septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:17:08 PM
Creation date
4/17/2019 10:12:29 AM
Metadata
Fields
Template:
x Address Old
House Number
1520
Street Name
Tanglewood
Street Type
Road
Address
1520 Tanglewood Road
Document Type
Septic
PIN
2611823320010
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PRESSURE DISTRIBUTION SYSTEM ENO PERFORATION OF A PERFORATED LATERAL_ <br /> firer Co. <br /> I. Select number of perforated laterals —3 Too"M <br /> Lay <br /> s►at Geeteenle Fearre(or rev <br /> •,..Leo"SOW Leger =ienr of her War"oo.ered <br /> 2. Select perforation spacing a .3 feet. <br /> r P Iferetlee 00111e41 Meruelttelly <br /> late Gap fiver Too <br /> 3. Since perforations should not be placed closer than 1 ft. to P"l " Rea aveLocto 121 r�°'. <br /> rale Fl.Id n« ._ of Race Laver <br /> the edge of the rock layer(see diagram), subtract 2 ft from Perfe►erlene'Looared of <br /> Gteae Saw LayerBertere of Leieral <br /> the rock layer length. <br /> Or1allo1 Sell PreoeAy Scerlrlee <br /> / -2 ft. feet. Before Plods° Seoul Layer <br /> Rode layer length TABLE OF PERFORATION DISCHARGES IN CPM <br /> 4. Determine the number of spaces between perforations. Head Per-'Oration liar e:er(inches) <br /> Divide the length above by perforation spacing and round '/a r�r <br /> down to nearest whole number. <br /> • 1.Oa S6 0.7 <br /> 1.5 0.69 0.90 <br /> Length perf. spacing —35 ft.+ 3 ft 13 spaces 2.ob OM IAA <br /> 2-5 039(3) (2) 0 0.98 128 <br /> 5. Number of perforations is equal to one plus the number of s.o 1.13 147 <br /> perforation spaces . <br /> 63 <br /> aL:se 1.0 foot of head for residential systems. <br /> ,L / bUse 2.0 feet of head for other establisharents <br /> 13 spaces + 1 =�perforations lateral <br /> M•o��JMM•r��1 r�efe10� <br /> PW%..W <br /> 6. Multiply perforations per lateral b number of laterals to ch 1- in <br /> PYP P Y �•, � I � ��h 1s�1cn 2.0 i,c:, <br /> get total number of perforations. 2.5 14 s 28 <br /> 1326 <br /> 12 166 25 <br /> uta, x ,/,��_ perforations. 4.0 11 15 23 <br /> 5.0 10 14 22 <br /> 7. Determine required flow rate by multiplying <br /> number of perforations by flow per perforation <br /> a d.7 oi <br /> _ gPm• <br /> rwro 1.0"10 •r oo a ret7ssR mn11a1rnoe rrsrlr <br /> P� gpm/peef <br /> 8. If laterals are connected to header pipe as shown on upper <br /> example, to select minimum required lateral diameter; enter <br /> table with perforation spacing and number of perforations <br /> per lateral. Select minimum diameter for <br /> perforated lateral = inches. <br /> urevr 0/q./ryr•IrJ♦r.f ur[I41 1s <br /> `n(J ML•Il P.r.rlrq.A.Ar.e <br /> 9. If perforated lateral system is attached to manifold pipe near --,-- <br /> the center,lower diagram,perforated lateral length and <br /> number of perforations per lateral will be approximately one <br /> half of that in step 8. Using these values,select minimum <br /> diameter for perforated lateral = �/z inches. <br />