Laserfiche WebLink
0 <br /> CITY of ORONO <br /> V , V - " Municipal Offices <br /> Street Address: 4:i Sa-a4 9-4 6o O Mailing Address: <br /> 2750 Kelley Parkway P.O. Non 56 <br /> Orono, MN 55356 Crystal Bay, UN 55323.0066 <br /> To Current Owner: Address: 15)-0 <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY (1-3): <br /> G "CODE SYSTEM"An LSTS which metes all the location,design and construction standards of the currmt Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An TsTS which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an imminent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISIS;an ISTS located within a designated 100-year flood plain,any ISIS which may <br /> or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting sor7 characteristics. <br /> TANK CONDMON(5-7): <br /> IM&inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped. ). <br /> Make sure septic tanks are pumped through manhole and not through white inspection Dices. This allows for the proper <br /> cleaning. Keep water seftner and iron filter discharge out of septic system to prolong We of drainfield. Ask pumper to test <br /> alarm float to verify alarm is still working in your house. The alarm warns owner that septage is about to backup into baseement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> D IELD CONDITION(8-10): <br /> Drainfield is dry,no surfacing evident. <br /> 8 . <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated eluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> CONMENTS: I`�o �tJ l► 6-o a-, <br /> S S� �-.- J Xci r5 <br /> Date of Inspection Matt Bolterman- Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does <br /> not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current <br /> editions based on the available information. <br />