Property address: 1460 Tanglewood Road,Orono, Inspector initials/Date: JS 1 10/11/2016 <br /> (mm/d&yyyy) <br /> 4. Soil Separation —Compliance component#4 of 5 <br /> Date of installation: 7/1/1984 ❑ Unknown Verification method(s): <br /> (mm/dd/yyyy) Soil observation does not expire. Previous soil <br /> Shoreland/Wellhead protection/Food beverage ❑ Yes ® No observations by two independent parties are sufficient, <br /> lodging? unless site conditions have been altered orlocal <br /> Compliance criteria: requirements differ. <br /> For systems built prior to April 1, 1996, and ® Yes ❑ No ® Conducted soil observation(s) (Attach boring logs) <br /> not located in Shoreland or Wellhead ❑ Two previous verifications(Attach boring logs) <br /> Protection Area or not serving a food, <br /> beverage or lodging establishment: ❑ Not applicable(Holding tank(s),no drainfield) <br /> Drainfield has at least a two-foot vertical ❑ Unable to verify(See Comments/Explanation) <br /> separation distance from periodically ❑ Other(See Comments/Explanation) <br /> saturated soil or bedrock. <br /> Non-performance systems built April 1, ❑ Yes [:] No Comments/Explanation: <br /> 1996, or later or for non-performance <br /> systems located in Shoreland or Wellhead Boring: <br /> Protection Areas or serving a food, 0-10" 10YR 2/2 Loam <br /> beverage, or lodging establishment: <br /> 11-16"10YR 4/4 Clay Loam <br /> Drainfield has a three-foot vertical <br /> separation distance from periodically Motts @ 16" <br /> saturated soil or bedrock." <br /> "Experimental", "Other'; or "Performance" ❑Yes [:] No Indicate depths or elevations <br /> systems built under pre-2008 Rules; Type IV <br /> or V systems built under 2008 Rules(7080. A. Bottom of distribution media 12-14" <br /> 2350 or 7080.2400 (Advanced Inspector <br /> License required) B. Periodically saturated soil/bedrock 16" <br /> Drainfield meets the designed vertical C. System separation 26"+ <br /> separation distance from periodically <br /> saturated soil or bedrock. <br /> D. Required compliance separation* 24" <br /> Any "no"answer above indicates the system is 'May be reduced up to 15 percent if allowed by Local <br /> failing to protect groundwater. Ordinance. <br /> 5. Operating Permit and Nitrogen BMP*— Compliance component#5 of 5 ® Not applicable <br /> Is the system operated under an Operating Permit? ❑ Yes ❑ No If"yes",A below is required <br /> Is the system required to employ a Nitrogen BMP? ❑ Yes ❑ No If"yes", B below is required <br /> BMP=Best Management Practice(s)specified in the system design <br /> If the answer to both questions is "no". this section does not need to be completed. <br /> Compliance criteria <br /> a. Operating Permit number: <br /> El Yes ❑ No <br /> Have the Operating Permit requirements been met? <br /> b. Is the required nitrogen BMP in place and properly functioning? ❑ Yes ❑ No <br /> Any "no"answer indicates Noncompliance. <br /> Upgrade Requirements(Minn. Stat.§115.55)An imminent threat to public health and safety(ITPHS)must be upgraded,replaced,or its use <br /> discontinued within ten months of receipt of this notice or within a shorter period if required by local ordinance. If the system is failing to protect <br /> ground water,the system must be upgraded,replaced,or its use discontinued within the time required by local ordinance. If an existing system <br /> is not failing as defined in law,and has at least two feet of design soil separation, then the system need not be upgraded, repaired,replaced,or <br /> its use discontinued,notwithstanding any local ordinance that is more strict. This provision does not apply to systems in shoreland areas, <br /> Wellhead Protection Areas,or those used in connection with food,beverage,and lodging establishments as defined in law. <br /> www.pca.state.mn.us • 651-296-6300 800-657-3864 TTY 651-282-5332 or 800-657-3864 • Available in alternative formats <br /> wq-wwists4-31 • 3116112 Page 3 of 3 <br />