My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2000-P02500 - addn/remodel/repair
Orono
>
Property Files
>
Street Address
>
T
>
Tamarack Drive
>
1065 Tamarack Drive - 26-118-23-31-0018
>
Permits/Inspections
>
2000-P02500 - addn/remodel/repair
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:16:43 PM
Creation date
4/16/2019 11:23:20 AM
Metadata
Fields
Template:
x Address Old
House Number
1065
Street Name
Tamarack
Street Type
Drive
Address
1065 Tamarack Drive
Document Type
Permits/Inspections
PIN
2611823310018
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RHVAC=Residentlal&Light Commercial HVAC Loads Program Elite 5oftwars Development,Inc. <br /> i Ditter,Inc. Graham <br /> Hamel,MN 55340-9691 rage 2 <br /> Total Building Summary Loads <br /> Component---- ----- --- ----- ---- ------------- ---- Area -- Sen. Lat. Sen. Total <br /> Description_ _ _ Quan Loss Gain Gain Gain <br /> 3A Window Double Pane Clear Glass Wood Frame 408 20,682 0 20,846 20,846 <br /> 8M Glass Door Double Clear Glass Wood Frame 84 4,258 0 3,990 3,990 <br /> 10F Door Wood Solid Core& Metal Storm 21 618 0 159 159 <br /> 12D Wall R-11 + 1/2"Asphlt Board(R-1.3) 2,079 15,301 0 3,925 3,925 <br /> 16G Ceiling R-30 Insulation 2,298 6,977 0 3,337 3,337 <br /> 22A Slab on Grade No Edge Insulation _ 288 21,462 0 0 0 <br /> Subtotals for structure: 5,178 69,298 0 32,257 32,257 <br /> Active People: 4 0 920 1,200 2,120 <br /> Inactive People: 0 0 0 0 0 <br /> Appliances: 0 0 0 1,600 1,600 <br /> Lighting: 0 0 0 <br /> Ductwork: 0 0 0 0 0 <br /> Infiltration: Winter CFM: 206.9, Summer CFM: 103.4 513 20,311 2,456 2,208 4,664 <br /> Ventilation: Winter CFM: 50.0, Summer CFM: 25.0 0 4,909 594 534 1,127 <br /> Sensible Gain Total: - 37,799- <br /> Temperature Swing Multiplier: X1.00 <br /> Building Load Totals: --- - --- - --- ------------- - - 94,518 3,970 37,799 41,768 <br /> Check Figures <br /> Total Building Supply CFM: 1746 CFM per square foot: 0.76 <br /> Square feet of room area: 2,298 Square feet per ton: 547.163 <br /> Building Loads <br /> Total heating required with outside air: 94,518 Btuh 94.518 MBH <br /> Total sensible gain: 37,799 Btuh 90 % <br /> Total latent gain: 3,970 Btuh 10 % <br /> Total cooling required with outside air: 41,768 Btuh 3.481 Tons(based on sensible + latent) <br /> 4.200 Tons (based on 75% sensible capacity) <br /> Notes <br /> Calculations are based on 7th edition of ACCA Manual J. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads. <br /> Saturday,May 27,2000 <br />
The URL can be used to link to this page
Your browser does not support the video tag.