Laserfiche WebLink
T OF ORONO �O� <br /> un ipet Offices O O <br /> os Office eox 66 <br /> Cr t l y, MN 55323-0066 a � ON—SITE SLWAGE TREATMENT <br /> �ti. <br /> INSPECTION REPORT <br /> ��9k o��G <br /> EsH. <br /> Owne : Address• <br /> Perm t #` Dates:�f�_Contractors: <br /> City o d na rnanber 100 requires that each on-site sewage treatment,system in Orono be inspected on a regular besis. <br /> The site ewage treatment system at the above address has been inspected and appears to fall into the category <br /> check l . <br /> . <br /> his is [ ] an existing system [ ] nea construction) <br /> TEM C F ITY 1-3 : � <br /> 1 'C SYSTEM"-A system which meets all the location, design, and construction standards of the current City <br /> es, and which is operating satisfactorily by treating and disposing of the entire current sewage input <br /> thout discharging any pollutants into ground or surfece weters. <br /> 2 'CO ORMING SYSTEM"•A system which does not meet all the location, design, and construction standards of the <br /> rrent City Codes, but was installed according to the code in effect at the time of installation, and which <br /> operating satisfactorily by treating and disposing of the entire current sewage input without discherging <br /> y pollutants into ground or surface uaters. <br /> 3 'NO CONFORMING STSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any <br /> stem which may or mey not meet all the locetion, design, and construction standards of the current City <br /> es and which is failing tor any reason; ,and any system with less than 3 feet of unsaturated soil or sand <br /> tween the distribution device and the lim�ting so�l characteristics. <br /> he limitin� soil characteristic [ ] has or [ � has not been identified at this time. If the limiting soil <br /> aracteristic has not been identified, this classification may be subject to revision.) <br /> TANK C �N ITI 5-10 : <br /> i s c ion irdicates: <br /> 5 I not needed at this time. <br /> o ids ccumulation in tanks indicates they should be aunped out this year to help prevent future problems. <br /> 7 o ids ccunulation in tanks is at a critical level. fianks should be punped out as soon as possible. <br /> 8 y t s discharging to the surface. Tanks must be pu�ped out within 48 hours to eliminate surface dischar$e. <br /> 9 n pec on risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each <br /> nk at next punipout. If tanks have not been punped out within the last three years, they should be punped ° <br /> t now. <br /> 10 n pe 'on pipe is lxated directly over tank baffle (does not give accurate measurement of solids accunulation). <br /> tanks have not been punped out within the last three years, they should be punped out now. <br /> � DRAINF E D DITION 11-14 : <br /> Dyri�f e d i spection indicates: <br /> V� r inf ld is dry, no surfacing evident. <br /> 12 o e e dence of surfacing, not critical yet. <br /> 13 r in eld is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> iately. Repairs must be completed within 90 days. <br /> 14 r inf ld extent and condition unknown. <br /> LiMITI G S1 FACTORS slo setbacks etc. : <br /> POTENT A F SYSTEM FAILURE de nds on soils water table etc. : <br /> CO S -� . Q' � <br /> � <br /> Date o Inspection S t Syatem Inspec or <br /> Note: I t event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> proper y edvised that this report does not guarantee or certify that an existing system will contirwe to f�ction <br /> proper y is merely en opim on of the adequacy of the system under current conditions based on the available <br /> tnfor t on. <br /> This report must be kept on the preinises with the system locstion and punping records. <br /> WHITE COPY/Inspectors Flle YELLOW COPY/Homeowner <br />