Laserfiche WebLink
� °� <br /> o..��.y _ o <br /> �„��=�� C ITY of ORONO <br /> ,� '+�����= � <br /> , � <br /> ? * "` Mi1111C1pa1 D�C@S <br /> �,�� �;���, .,. ;.���� � <br /> � �� r� � <br /> \� �•,:- ����r 4,�,G/ Street Address: `'�5a-a49—y 6o O Mailing Address: <br /> '� �,e,;.. . <br /> .. x'�KQ ' 2750 Kelley Parkway P.O. Box 66 <br /> ��� Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: `3c r 1 `��S s�� x �, <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM COIVFORMIT'Y (1-3): 1 <br /> 1 "CODE SYSTEM"An LSTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An LSTS which does not meet all the location,design and construcdon standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an imminent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction stan�rds of the current Orono Municipal Code and which is failiag for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the dishibution device and the limiting soil characterisdcs. <br /> TANK CONDTTION(5-7): (C7 <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped �7- �t "O 1 ). <br /> Make sure semtic tanks are aumaed throush manhole and not throuEh white inspection pipes. This allows for the uroper <br /> cleaninE. Keea water softner and iron filter discharse out of septic system to prolong life of drainfield. Ask numper to test <br /> alarm float to verifv alarm is still workin¢in your house. T6e alarm warns owner that septage is about to backua into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DR.AINFIELD CONDITION(8-10): � <br /> 8 Drainfield is dry,no surfacing evident, <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: <br /> �, - ;,� f —c�J .� ���.,�.�. <br /> �, <br /> Date of Inspeetion Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does <br /> not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current <br />