Laserfiche WebLink
� Carol O'BRIEN <br /> � +-11�-1��� ARCHITECTURE, PLLC <br /> KITCHEN - EXISTING <br /> �p Bunkers &Associates LLC TEL:(612)247-3639 <br /> a structura engineers <br /> ca rol Occobriena rch.com <br /> 6687 Forest Street <br /> Farmington, MN 55024 <br /> 2 651.366.2853 <br /> A201 Date: April 27,2015 <br /> To: Carol O'Brien Architecture,PLLC <br /> 19255 Cedarhurst <br /> - PORCH - EXISTING Deephaven,MN 55391 <br /> r Attn: Carol O'Brien,Architect <br /> T <br /> M From: Eric Bunkers <br /> '— Project: Cristiani Residence � <br /> + 3011 Sussex Rd. <br /> GUARDRAILS&POSTS Orono,MN 55356 <br /> TO BE CAPABLE OF Proj.No: 15102 � � <br /> SUPPORTING 200 LBS Subject: Proposed DeckAddition — .�..J � M <br /> LOAD IN ANY DIRECTION •� •— � � <br /> Dear Carol: � � x Z <br /> 10�-0�� 6�-0�� As requested,we designed new structural members for the above referenced project. We have designed the ,�,J � v�i <br /> EXIST.STAIR& � vi � <br /> LANDING new members using a roof and floor dead load of 15 psf and a floor live load of 40 psf in accordance with the � � <br /> Minnesota State Building Code. Our work only includes designing the new members as shown at the above N 0 <br /> reference project and is based on drawings provided by you and from our conversations. •1_ �/ � � <br /> � v � <br /> Attached are 3 structural sheets with annotated framing notes showing the new members and connections. 0 O <br /> ! All framing shall be shored and temporarily braced as required by the contractor and all minimum nailing Q f M� <br /> i shall be in accordance with IRC Table R602.3(1). Lumber shall be treated lumber to be#2 S.Pine or Q <br /> I STAIR - c7 equivalent and untreated shall be#2 SPF or equivalent and painted. Our calculations assume all lumber is <br /> ': EXIST = Z of good quality and does not have large splits and checks and shall be visually inspected by the contractor at <br /> 0 <br /> D N i � ~ the time of construction. All fasteners in contact with treated lumber shall be G185 hot di ed alvanized or <br /> - pP 9 <br /> � <br /> � � — <br /> 17 R I e uai. Rebar shall be rade 60. <br /> x <br /> 9 9 <br /> PROVIDE GAS LINE 16 T � I + w <br /> AS REQUIRED FOR EXIST. Concrete used for footings(4"slump)shall have a 28 day compressive strength of 3000 psi. The new <br /> GRILL _ (� footings have been designed as a typical spread footing based on a presumptive load-bearing value of 2000 <br /> I � Z psf in accordance with Table R401.4.1 of the IRC. The existing footings have been assumed to be typical <br /> I REPLACE EXIST. p �j spread footings on good soils that are assumed to be performing adequately. The contractor shall also verify <br /> i TREADS, RISERS AND r X the condition of structural members and foundations affected by the remodeling. Exterior grade shall slope <br /> � <br /> � DECK- NEW RAILINGCODE + W away from the building and gutters with long downspouts should be used whenever possible. Foundation <br /> ' ', AZEK 1' X 5 1/21"DEGcKING O/ ' backfill shall be granular and well compacted. <br /> T � TRTD Z X�Z F.J.�� �V O.C. iHf5E00CJMf�IiSM`ENJSiRUMfN�50F5:4V:CF <br /> When instalied as indicated above,the new framing members and new foundations shown on the attached A'+onssucnx�n?nivaovexrvorco,d <br /> M ETAL HAN D RA I L� O'BA�r1i A0.CM�LFRUPE,V:G U5:OP VUBUUI ON <br /> sheets shall support the loads as required in accordance with the Minnesota State Building Code. If you pYO�RFS WRIi`EHMVRO��tFROMLordUBPEn <br /> PER CODE �TECURF,�UC. <br /> have any questions or concems,PI@SSB}@@I fr@8 t0 COf1YdCt US. DO NOT DETERMINE DIMENSIONS BY <br /> AZEK FASCIA BOARD I $GALMG OFF THESE DRAWINGS <br /> 36���I�. �I�� � Sincerely� 1lIESEDRAW�NGSAiFAGRAVWCREPRFSFNT�TON <br /> pND 4PE Nql IMEI:DfD i0 PPOV�DIMfN51J>10. <br /> METAL � Bunkers and Associates LLC NiiOPMA➢ON,E%U3TWNfPfU1MFNLUNSARE <br /> G UA R D RA I L� SVEC1FKwLLT INDiGikD.SMOUID YOU 4FOUIRE <br /> f A091110.Wt D�MENSIONS,aLU.SE CONiAR THE <br /> PER CODE� _ � � ����� <br /> i �.� Project Number: <br /> �sooz <br /> � � Eric M.Bunkers,P.E. Pro'ect Architect: <br /> i i MN Reg.Num.26490 I hereby certity that this plan,specification,or report � <br /> was prepared by me or under my direct supervision CAAOL O'BRIEN <br /> � and that I am a duly Licensed Professional Engineer <br /> -- under the laws ot the state of Minnesota. ��q W� gy: <br /> �-�G CO <br /> Eric M.Bunkers <br /> Date of Issue• <br /> 16�-��� +" ]�-`3�� +- 4�-Q�� Date:Aori127.2015 Reg.No.26490 Struct. Review <br /> EXISTING EXISTING 4.25.15,4.28.15 <br /> 5.9.15 <br /> 1 <br /> A201 <br /> 1 Main Level 2 Structural Notes <br /> 1 O Sheet A,�O� <br /> 1 0 SCALE: 1/4" = 1'-0" � Z 4 8 No. <br /> e�,:>�. <br /> �; <br />