Laserfiche WebLink
� °� <br /> 0 0 <br /> �����������- ciTY of oRONo <br /> ,���.} <br /> ,.� �8��:r�„�' ..�. �+ <br /> ��, �+°� d ��.; ' �l4 Municipal Offices <br /> ��� ��� -r� _:��,�G Street Address: �15a-a4 q—y 60 0 Mailing Address: <br /> �, l �•.�,�. �r.� . <br /> \\ESHp� 2150 Keiley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address:� � �� S� �� �t 1� rl <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMIT'Y (1-3): � <br /> 1 "CODE SYSTEM"An ISTS which meets all the location,design and construcNon standazds of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the locadon,design and conshvction standards of the current Orono <br /> Municipal Code but does meet the three foot sepazation requirement or rivo foot requ'uement for systems installed 1996 or earlier,and <br /> which is not failing or an imminent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failiag for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the dish-ibution devico and the limitiag soil characterisrics. <br /> TANK CONDITION(5-71: � <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this yeaz (city code recommends tanks to be pumped out once every 3 yeazs. <br /> Tank was last pumped ). <br /> Make sure septic tanks are aumaed throueh manhote and not throush white insaection aines. This allows for the vrouer <br /> cleanine. Keea water softner and iron filter discharee out of seatic svstem to prolone life of drainfield. Ask numaer to test <br /> alarm float to verifv alarm is still workins in vour house. The alarm warns owner that septaEe is about to backuu into basement <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DR.AINFIELD CONDITION(8-101: � <br /> 8 Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the CiTy Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: <br /> �� <br /> � _ � � �� � <br /> Date of Inspection Septic System Inspector <br /> Note` 1n the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does <br /> not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current <br />