My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info
Orono
>
Property Files
>
Street Address
>
S
>
Sussex Lane
>
455 Sussex Lane - 04-117-23-32-0011
>
Septic
>
septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:11:59 PM
Creation date
4/4/2019 2:45:44 PM
Metadata
Fields
Template:
x Address Old
House Number
455
Street Name
Sussex
Street Type
Lane
Address
455 Sussex La
Document Type
Septic
PIN
0411723320011
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
+ ' Preliminary Plat of Fox Bend - Septic System Testing <br /> August 22, 1989 <br /> Page 4 of 4 <br /> General Cc�ments - <br /> Each proposed lot appears to have suitable primary and <br /> alternate drainfield sites. On some lots, the primary and <br /> alternate sites shown are the onl possible sites available. On <br /> other lots, it is likely that additional testing could find a <br /> number of potential sites, allowing additional flexibility in <br /> house placement. <br /> In each case, drainfield sites have been designed to meet <br /> the minimum 20' setback from property Iines, and 75' setbacks <br /> from designated wetlands. � <br /> On the majority of lots, extreme cantion must be taken <br /> during construction of improvements to the property. Road <br /> construction will take place within 50' of tested drainfield <br /> sites on at least 6 of 17 lots, and on 2 lots the sites are <br /> relatively near the area proposed to be graded to provide a <br /> detention basin. I would recommend that each lot have drainfield <br /> sites protected by snow fence totally surrounding the drainfield <br /> sites at a distance 20' from the boundaries of each drainfield <br /> system. Additionally, when road construction plans are <br /> submitted, I would like to review them to determine where road <br /> cut would have a potential impact on drainfield sites. <br /> Swomary - <br /> Out of 34 drainfield sites tested, 29 require mound systems <br /> and 5 would allow a trench-type system. Each lot has primary and <br /> alternate sites designated. It would not be surprising if as <br /> many as 20$ of the sites ultimately will have to be re-tested due <br /> to the buyer's preference for house sites near or conflicting <br /> with drainfields. Some lots are extremely limited for potential <br /> drainfield sites, others provide a degree of f Iexibility in house <br /> placement. <br /> Given the above facts, concerns, and constraints, I would � <br /> recommend approval of the subdivision as proposed. Accompanying <br /> this memo is a topographic survey of the preliminary plat showing <br /> potential house locations and locations of both primary and <br /> alternate drainfield sites. <br />
The URL can be used to link to this page
Your browser does not support the video tag.