� _ -Residential&Ught Commerclal HVAC Loads Program � Elite So re Dove oprh�nt, nC. <br /> .,.- <br /> '` 'fi,Inc. ►, D.POSt NEIiV HOiV1� <br /> �ti'ial,MN 55340-9691 06-04-1996 � p���� <br /> Project Summary <br /> Design Data <br /> Project Name: D. POST NEW HOME <br /> Reference City: Minneapolis, Minnesota <br /> Daily Temperature Range: Medium <br /> Latitude: 44 Degrees <br /> Elevation: 834 Feet <br /> Outdoor Outdoor Indoor Indoor Grains <br /> Ib e B I Rel.Hum. � Bulb Difference <br /> Winter: -20 N/A N/A 72 N/A <br /> Summer: 95 75 50% 75 36 <br /> Check Figures <br /> Total Building Supply CFM: 2064 CFM per square foot: 0.306 <br /> Square feet of room area: 6,744 Square feet per ton: 1,372.054 - <br /> Building Loads <br /> Total heating required with outside air: 112,235 Btuh 112.235 MBH <br /> Total sensible gain: 45,417 Btuh 83 % <br /> Total latent gain: 9,377 Btuh 17 % <br /> Total cooling required with outside air: 54,794 Btuh 4.566 Tons (based on sensible + latent) <br /> 4.915 Tons (based on 77% sensible <br /> capacit ) <br /> Y <br /> Notes <br /> Calculations are based on 7th edition of ACCA Manual J. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads. <br />