My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info
Orono
>
Property Files
>
Street Address
>
S
>
Sussex Circle
>
560 Sussex Circle - 04-117-23-32-0020
>
Septic
>
septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:12:13 PM
Creation date
4/4/2019 1:12:16 PM
Metadata
Fields
Template:
x Address Old
House Number
560
Street Name
Sussex
Street Type
Circle
Address
560 Sussex Cir
Document Type
Septic
PIN
0411723320020
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� °� <br /> o :. o <br /> ��-�' CITY of ORONO <br /> � 'r��r`�;�- �„ <br /> ���3��¢c' � – ��C, Municipal Offices <br /> '�\�� `��r,,��,5����YV.�,.1!�' `.�. _ <br /> \� " ��} �+���,���` G Street Address: q 5a-a4 q �60 o Mailing Address• <br /> ��`�1�Eg�Kpfi��'/ 2150 Kelley Parkway P.O. Box 66 <br /> �— Orano, MN 55356 Crystal Bay, MN 55323•0066 <br /> To Current Owner: Address: �� s 5�J S SC' �C C����=' �� <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two yeazs. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMIT'Y (1-31: � <br /> 1 "CODE SYSTEM"An LSTS whicb meets all the location,design and construcrion standards of the cu►rent Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separadon requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an i�inent threat to public health or safety. � <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction standirds of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than thrce feet of unsaturated soil or sand between the distribution ckvice and the limiting soil characteristics. <br /> TANK CONDITION(5-71: � <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped / [�— 3/�-�� )• <br /> Make sure seatir tanks are aumaed throush manhole and not throush white inspection aiaes. This allows for the arooer <br /> cleanins. Keep water softner and iron filter discharee out of seatic svstem to prolons life of drainfield. Ask pumaer to test <br /> alarm float to verifv alarm is still workin�in vour house. The alarm warns owner that septage is about to backup into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDITION(8-101: � <br /> 8 Drainfield is dry,no surfacing evident, <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: <br /> �o �-� � 'U' J ��(,���C.�,= ��r,�� <br /> �" Mnh..�. <br /> Date of Inspection Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of properry,be advised that this report does <br /> not guazantee or certify thaU an existing system will continue to funclion properly, but is merely an opinion of the adequacy of fhe system under current <br />
The URL can be used to link to this page
Your browser does not support the video tag.