Laserfiche WebLink
� °� <br /> o :. o <br /> ��-�' CITY of ORONO <br /> � 'r��r`�;�- �„ <br /> ���3��¢c' � – ��C, Municipal Offices <br /> '�\�� `��r,,��,5����YV.�,.1!�' `.�. _ <br /> \� " ��} �+���,���` G Street Address: q 5a-a4 q �60 o Mailing Address• <br /> ��`�1�Eg�Kpfi��'/ 2150 Kelley Parkway P.O. Box 66 <br /> �— Orano, MN 55356 Crystal Bay, MN 55323•0066 <br /> To Current Owner: Address: �� s 5�J S SC' �C C����=' �� <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two yeazs. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMIT'Y (1-31: � <br /> 1 "CODE SYSTEM"An LSTS whicb meets all the location,design and construcrion standards of the cu►rent Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separadon requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an i�inent threat to public health or safety. � <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction standirds of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than thrce feet of unsaturated soil or sand between the distribution ckvice and the limiting soil characteristics. <br /> TANK CONDITION(5-71: � <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped / [�— 3/�-�� )• <br /> Make sure seatir tanks are aumaed throush manhole and not throush white inspection aiaes. This allows for the arooer <br /> cleanins. Keep water softner and iron filter discharee out of seatic svstem to prolons life of drainfield. Ask pumaer to test <br /> alarm float to verifv alarm is still workin�in vour house. The alarm warns owner that septage is about to backup into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDITION(8-101: � <br /> 8 Drainfield is dry,no surfacing evident, <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: <br /> �o �-� � 'U' J ��(,���C.�,= ��r,�� <br /> �" Mnh..�. <br /> Date of Inspection Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of properry,be advised that this report does <br /> not guazantee or certify thaU an existing system will continue to funclion properly, but is merely an opinion of the adequacy of fhe system under current <br />