Laserfiche WebLink
� °� <br /> 0 0 <br /> =� � CITY of ORONU <br /> ,� �r.���:-��: � <br /> �'`�!;, „x' <br /> 1 b� d ��,;:;-.:�". �ti Municipal Offices <br /> ,\"� �!� �.��.��,�' <br /> ,�,'� ����"-���'� �' <br /> ��� ���, � Street Address: �15a-a4°I-y 60 o Mailing Address: <br /> �\�� .:-�.,�. ;,. ,¢�i <br /> �ESI;� � 2750 Kelley Parkway P.O. Box 66 <br /> % Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Cunent Owner: Address: S�S S:� .�Sc'X ��'/��'I t� <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY (1-3): I <br /> 1 "CODE SYSTEM" An ISTS which meets all the location,design and consnuction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An 7STS which does not meet all the location,design and conshvcrion standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an imminent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibiud ISTS;an ISTS located within a desigaated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any <br /> reason;and any LSTS with less than Uuee feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-7): �� <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped ). <br /> Make sure seatic tanks are uumaed throueh manhole and not throush white insaection piaes. T6is allows for the aroaer <br /> cleanine. Keea water softner and iron filter discharee out of seatic svstem to prolone life of drainfield. Ask numaer to test <br /> alarm float to verifv alarm is still workin¢in your house. The alarm warns owner that septaee is about to backua into basement <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDITION(8-10): � <br /> 8 Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: <br /> � .�/._ � ; ��.��...�?. �,,��'�...�'.:�, <br /> . <br /> Date of Inspection Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does <br /> not guazantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current <br />