Laserfiche WebLink
01999 Westwood Professional Services, Inc. <br /> 1 ,,,_, ..s7:s<- <br /> LEGEND <br /> ---7- <br /> YS TE /// <br /> Ow existing we// <br /> (418+ LF OF 10 ID 0 soil boring <br /> 316?. <br /> GRAVELESS TRE H) N O percolation test <br /> x - existing fence <br /> .\ <br /> existing deciduous tree <br /> _ DROP BOX (TY * existing coniferous tree <br /> ---1 ---'1.----------------- A . - - - - existing elevation contour <br /> Ik O <br /> 92*4 exist/ng spot elevation <br /> S624 •li�""� ..------B 6 2-1 •. tk ' LLO S PTI I (92x4 proposed spot elevation <br /> / 5625 PRECAST EPTI T` \ \... <br /> P❑/ Elevations relative and assumed <br /> eKgE0Elevations relative to ti S.G.S. 1929 N.G.VD. <br /> • ROC 6 �11 Denotes proposed surface drainage <br /> Nv <br /> Il ' <br /> SB27 18. ° ; h <br /> SB29 11040 , ` Notes: <br /> \ �� 1. Avoid compaction in septic area before, during and <br /> ® ALTERNATE SEPTIC SITE �• ► after construction <br /> M e ► I SYSTEM WITH PUMP TANK , e .4 0 2. Trenches are to be installed parallel to the contours and the <br /> A 630 'OCK BED) trench excavations are not to exceed a maximum depth of 44isk <br /> 12 inches below the existing ground surface. <br /> o <br /> `ROPOSEP <br /> J. Verify before drilling that no septic tanks or drain fie/ds <br /> L • <br /> are within o 50 foot radius of proposed we// location. <br /> r\\.:AA \ (100 feet for shallow we//) <br /> 4. Verify before construction that no shallow wells are within <br /> 100 feet, or deep we//s within 50 feet of proposed septic <br /> X tanks or drainfield area. <br /> At$4;\.\ \ <br /> I 5. To extend the life of septic system pump septic tanks a <br /> minimum of every 2 years. <br /> 6. <br /> • <br /> Nii# <br /> See attached sheets for additional construction details. <br /> ' � \ '` 7 Soil Classified as Burnsville sandy loam (BuC) 6-122'slopes, <br /> / according to the U.S. Department of Agriculture soil Survey <br /> © 0 8. Site p/an prepared by or under the supervision of Bernie <br /> Miller- .P.C.A. License N 3 <br /> r ......-4 <br /> „ . <br /> Date 7-# , <br /> N.--. *-------- ' - -1—liI <br /> 948 / 0 40 80 120 <br /> y Westwood Property location: DESIGNED BCM REQUESTED BY: DATE <br /> [ <br /> Westwood Professional Services, Inc ] <br /> BCM Septic System 4/20/89 <br /> I [ <br /> 104 Marty Drive, Suite 3 Lot 6, CARRIAGE HILL, Orono DRAWN Bohland Development <br /> Buffalo, MN 55313 CHECKED JMc Site Plan <br /> 612 682-2587 Job No. <br /> ��� <br /> Plymouth,MN. 98795 <br />