Laserfiche WebLink
°1999 Westwood Professional Services, Inc. <br /> 1 \ <br /> LEGEND <br /> .� *s. <br /> ----75:--WE <br /> ' I 111111 <br /> \w existing we// <br /> _� � I1`-`5--_WETLAND TBACK <br /> If i \ soil boring <br /> ;_ . percolation test <br /> " <br /> 411" - ATE SEPTIC SITE G <br /> A.-- 41 . OF 10 ID x existing fence <br /> ,7& -"--- �'� G' ' EL TR 00 > existing deciduous tree <br /> li S- B4 6' <br /> 9 co4 <br /> existing coniferous tree <br /> • Z, - SB36 , `tr E/ • •AFglow LAND existing elevation contour <br /> 9 \ \ 92x4 existing spot elevation <br /> 9 192x41 proposed spot elevation <br /> `� " S \ \ 0 Elevations relative and assumed <br /> • S: ,0/4 \n 9.57(5 <br /> .57(5 \ 12( Elevations relative to U.S.G"S. 1929 N.G.V.D. <br /> SB1 O,p <br /> Q � Denotes proposed surface drainage <br /> • <br /> / \ PRIM Y SEPTIC - ST 66\-1-- sl 'O\ SB� \ Notes: <br /> 4 LF OF 10 'D GRAVEL SS o' S 1. Avoid compaction in septic area before, during and <br /> TRENCH) }A after construction <br /> 6, S 1 2 Trenches are to be instal/ed parallel to the contours and the <br /> trench excavatioos are not to exceed a maximum depth of <br /> / S� \ \ 12 inches below the existing ground surface. <br /> \ \ \ t )( 3 Verify before drilling that no septic tanks or drain/gelds <br /> 2-1300 GALLON PRE— are within a 50 foot radius of proposed we// location. <br /> (100 feet for shallow well) <br /> CAST OPTIC TAS; '! <br /> 4. Verify before construction that no shallow wells are within <br /> 100 feet, or deep we//s within 50 feet of proposed septic <br /> \ 0 -\ tanks or drain field area. <br /> X ".•..„... ‘ <br /> 5. To extend the life of septic system pump septic tanks a <br /> ` minimum of every 2 years. <br /> N ( \ <br /> \\ 6. See attached sheets for additional construction details. <br /> 7 Soil Classified as Burnsville sandy loam (BuC) 6-12% slopes, <br /> - <br /> SB' PROPOSED 5 BED <br /> "� )► according to the U.S. Deportment of Agriculture soil Survey <br /> BOOM HOMEv. <br /> 8. Site plan prepared by or under the supervision of Bernie <br /> 910 <br /> (� �\ Mi/ler— M.P.C.A. Livens No. 43 <br /> PROPOSED <br /> WELL `9 \ DateV 2/—P!, <br /> -- \.... .,---\\- \ <br /> \N <br /> \ \ \ � 0 40 80 120 <br /> \ \ / \ \ \lir \ <br /> I [ REQUESTED BY: DATE <br /> Weswood Property location: DESIGNED BCM 4120/99) <br /> [ <br /> Westwood Professional Services, Inc <br /> DRa , BCM Septic System <br /> 104 Marty Drive, Suite 3 Lot 3, CARRIAGE HILL, Orono Site Plan Bohland Development <br /> Buffalo, MN 55313 CHECKED JMc Job No. <br /> 612 682-2587 <br /> \.. Plymouth,MN. 98795 <br />