Laserfiche WebLink
CITY OF ORONO � O� <br /> Municipal Offices O O <br /> Post Office Box 66 <br /> Crystal Bay, MN 55323-0066 � � ON—SITE SEWAC�E TREATI�NT <br /> ti INSPECTION REPORT <br /> � Gti <br /> �9xESII04`'� <br /> Owner: WC�d�� L/Gt/J/� Address: y� d���3' �i4y /p�• •S � �.3'.�'�9 ) <br /> / /� / J <br /> Permit #'a: (S� Dates:_ �1 �o���bb Contractors: /J�K)�S /��pg <br /> City ordinance number 100 requires that each o�-site sewage treatment system in Ororw be inspected on. a regular besis. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall �nto the category <br /> checked below. <br /> (This is �an existing system [ ) new construction) <br /> SYSTEM CONFORMITY (1-3): <br /> 1 "COOE STSTEM"-A system which meets all the location, design, a�d consiruction standards of the current City <br /> Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input <br /> without discherging any pollutants into ground or surface waters. <br /> 2 "CONFORMING STSTEM��-A system which does not meet all the locatian, design, and construction standards of the <br /> current City Codes, but was installed according to the code in effect at the time of installation, and which <br /> is operating satisfactorily by treating and disposing of the entire current sewage input without discharging <br /> any pollutants into ground or surface waters. <br /> 3 "NON-CONFORMING STSTEM"-A prohibited system; a system located within a designated 100-year floodptain; any <br /> system which may or may not meet all the location, design, and construction standards of the current City <br /> Codes and which is failing for any reason; and any.system with less than 3 feet of unsaturated soil or sand <br /> between the distribution device and the limiting soil characteristics. <br /> (The limitin� soil characteristic �has or [ 7 has not been identified at this time. If the timiting soil <br /> characterist�c has not been identi i , this classification may be subject to revision.) <br /> TANK CONDITION CS-10): <br /> Tank inspection indicates: <br /> 5 Punpout not needed at this time. <br /> 6 Solids accunulation in tanks indicates they should be punped out this year to help prevent future problems. <br /> 7 Solids accunulation in tanks is at a critical levet. ranks should be punped out as soon as possible. <br /> � System is discharg`ing to the surface. Tanks must be punped out within 48 hours to eliminate surface discharye. <br /> Inspection risers missing-tanks could not be inspected. Inspection risers (4�� dia, pipe) must be installed in each <br /> tank at next �wn�out. If tanks have not been punped out within the last three years, they should be pu�ed <br /> out now. <br /> 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accunulation). <br /> If tanks have not been punped out within the Last three years, they should be punped out now. <br /> DRAINFIELD CONDITION (11-14): �� <br /> D�field inspection indicates: <br /> 1 Drainfie[d is dry, no surfacing evident. <br /> Sane evidence of surfacing, not critical yet. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately. Repairs must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> LIMITING SITE FACTORS (slope.setbacks.etc.): H/�T�TA.,g� E <br /> POTENTIAL FOR SYSTEM FAiLURE (deoends on soils.water table etc ): M�cA�(�� <br /> ' COMMENTS: S �e -�o �. !i' �ac � ��3/-24t�G c�u� .J ae�c <br /> ' Y ;net !dW. <br /> _ � <br /> Date of nspection Septic Syste Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, be advised that this report does not guarantee or certify that an existing system will continue to f�ction <br /> properlyi but is merely an opinion of the adequacy of the system under current conditions based on the available <br /> �nformation. <br /> �This report must be kept on the premises with the system toeetion and punping records. <br /> WHITE COPY/Inspecton File YELLOW COPY/Homeowner <br />