Laserfiche WebLink
� o� <br /> 0 0 <br /> � �,��,_ ,� CITY of ORONO <br /> �� ��F�� ,��r � ti M������ ot��� <br /> !H(�ur I��,�¢�F�i,P �~ <br /> ,t � ,,�<`�ry.��� .� Street Address: Mailing Add�ess: <br /> 9 �"�ti� g' <br /> $�gg0 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323•0066 <br /> �� ` ."l �l l � <br /> Owner: �n!�C�� ��r-� -[ ��..(�1_% Address:485 Stubbs Bay Rd. N. <br /> Permit #'s:2320, 5381 Dates:l0/31/69, 10/26/78 Contractors:Day Plbg. , Sullivan <br /> (This is �] an existing system [ ] new construction) <br /> SYSTEM COMPLIANCE (1-3) : 3 <br /> 1 Code Svstem,: Meets or exceeds current City standards in all respects relating to <br /> design, construction, and location. Appears to be operating properly. <br /> 2 Compliant Svstem: Does not meet all current City standards for new construction, <br /> but in most respects appears to be designed, located, and constructed in accordance <br /> with previous codes and is functioning properly. <br /> � Non-Compliant Svstem: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the <br /> current input; and any system with less than three feet of vertical separation <br /> between the bottom of the drainfield and the saturated soil level. <br /> (The saturated soil level � has or [ ] has not been identified at this time. If the <br /> saturated soil level has not been identified, this classification is subject to revision.)_ <br /> �,ANK CONDITION 5-9 : 5 <br /> (5` Pumpout not needed at this time <br /> 6 Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been <br /> pumped out within three years, they should be pumped out and risers installed now. <br /> 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If <br /> tanks have not been pumped out within three years, they should be pumped out now. <br /> (During the last septic tank Maintenance Pumpout the tanks [ ] were or � were not <br /> confirmed to be watertight by the licensed pumping contractor. If the anks were not <br /> confirmed to be watertight, this classification is subject to revision.) <br /> INFIELD CONDITION 11-14 : 11 <br /> 11 Drainfield is dry, no surfacing evident. <br /> 1 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br /> Contact the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (svstem aQe and condition, soils, etc. ) : medium <br /> CONIl�IENTS: The non-compliant septic system must be repaired by 12/31/2006 or within 90 days <br /> of failure (surface discharge) , whichever comes first. <br /> -�—J�y��? � i��';�� <br /> Date of Inspection Sep ic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue <br /> to function properly, but indicates the operation of the system under current conditions. <br /> Telephone (612) 473-7357 • FAX 473-0510 <br />