My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017-00803 - solar energy system
Orono
>
Property Files
>
Street Address
>
S
>
Stubbs Bay Road North
>
480 Stubbs Bay Road North - 32-118-23-13-0003
>
Permits/Inspections
>
2017-00803 - solar energy system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:39:20 PM
Creation date
3/20/2019 1:23:18 PM
Metadata
Fields
Template:
x Address Old
House Number
480
Street Name
Stubbs Bay
Street Type
Road
Street Direction
North
Address
480 Stubbs Bay Road North
Document Type
Permits/Inspections
PIN
3211823130003
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Series 200 �n� ,t r���.. <br /> , , � � <br /> Configuration Tables for Ground Mount System 41 to 50 psf Snow Loads(4 Module Panels) '" , <br /> 100 mph Wind Load 41-50 psf Snow <br /> Standard Installation Braced Installation Numbe�of Raiis Required Per Panel <br /> Tilt Angle B Max(PS) 12"Dia Pier Required Braces Max(PS) 12"Dia Pier Required Braces Module Sfze <br /> Sch 40 Sch 80 Short Tall A C D Sch 40 Sch 80 Short Tall A E F 40"x 66" 40"x 78" <br /> B=0 66 75 30 30 No Every 3rd Bay No 180 180 44 44 Yes Yes Yes 2 2 <br /> 0 >9<7.5 64 73 30 30 Yes Every 3rd Bay No 180 180 44 44 Yes Yes Yes 2 2 <br /> 7.5>8<15 65 74 30 31 Yes Every 3rd Bay No 180 180 44 44 Yes Yes Yes 2 2 <br /> 15>9<22.5 69 78 30 37 Yes Every 3rd Bay Every 3rd Bay 180 180 35 52 Yes Yes Yes 2 2 <br /> 22.5>B<30 73 83 30 41 Yes Every 3rd Bay Every 3rd Bay 180 180 35 56 Yes Yes Yes 2 2 <br /> 30>9<37.5 79 90 30 45 Ves Every 3rd Bay Every 3rd Bay 179 180 30 59 Yes Yes Yes 2 2 <br /> 37.5>B<45 86 98 30 48 Yes Every 3rd Bay Every 3rd Bay 168 180 30 62 Yes Yes Yes 2 2 <br /> 110 mph Wind Load 41-50 psf Snow <br /> Standard Installation Braced Installation Number of Rails Required Per Panel <br /> Tilt Angle B Max(PS) 12"Dia Pier Required Braces Max(PS) 12"Dia Pier Required Braces Module Size <br /> Sch 40 Sch 80 Short Tall A C D Sch 40 Sch 80 Short Tall A E F 40"x 66" 40"z 78" <br /> 0=0 65 75 30 30 No Every 3rd Bay No 180 180 48 48 Yes Yes Yes 2 3 <br /> 0 >B<7.5 63 72 30 30 Yes Every 3rd Bay No 180 180 48 48 Yes Yes Yes 2 3 <br /> 7.5>9<15 64 74 30 33 Yes Every 3rd Bay No 180 180 48 48 Yes Yes Yes 2 3 <br /> 15>B<22.5 68 77 30 40 Yes Every 3rd Bay Every 3rd Bay 1S0 180 38 57 Yes Ye5 Yes 2 2 <br /> 22.5>B<30 71 81 30 44 Yes Every 3rd Bay Every 3rd Bay 174 180 38 61 Yes Yes Yes 2 2 <br /> 30>9<37.5 77 88 30 48 Yes Every 3rd Bay Every 3rd Bay 163 180 30 63 Yes Yes Yes 2 2 <br /> 37.5>9<45 83 95 30 51 Yes Every 3rd Bay Every 3rd Bay 153 175 30 66 Yes Yes Yes 2 2 <br /> 120 mph Wind Load 41-50 psf Snow <br /> Standard Installation Breced Installation Number of Rails Required Per Panel <br /> Tilt Angle 0 Max(P5) 12"Dia Pier Required Breces Max(PS) 12"Dia Pier Required Braces Module Size <br /> Sch 40 Sch 80 Short Tall A C D Sch 40 Sch 80 Short Tall A E F 40"x 66" 40"x 78" <br /> B=0 65 74 30 30 No Every 3rd Bay No 180 180 52 52 Yes Yes Yes 2 3 <br /> 0 >0<7.5 62 71 30 30 Yes Every 3rd Bay No 180 180 52 52 Yes Yes Yes 2 3 <br /> 7.5>9<15 64 73 30 35 Yes Every 3rd Bay No 180 180 41 52 Yes Yes Yes 2 3 <br /> 15>B<22.5 67 76 30 42 Yes Every 3rd Bay Every 3rd Bay 180 180 41 62 Yes Yes Yes 2 3 ' <br /> 22.5>B<30 70 79 30 47 Yes Every 3rd Bay Every 3rd Bay 159 180 30 64 Yes Yes Yes 2 2 <br /> 30>B<37.5 75 86 30 51 Yes Every 3rd Bay Every 3rd Bay 149 170 30 66 Yes Yes Yes 2 2 <br /> 37.5>B<45 81 93 30 54 Yes Every 3rd Bay Every 3rd Bay 140 160 30 69 Yes Yes Yes 2 2 <br /> NSSE 5022 Sunrise Boulevard Fair Oaks CA 95628(916)536-9585 Page 34 of 96 <br />
The URL can be used to link to this page
Your browser does not support the video tag.