Laserfiche WebLink
06l27/2017 14:15 Riccar Heating �AK}763 754 0132 P.007l008 <br /> �R c-�R;�I�en�la1��ugHt��om.�iercfa..�IVAC�Loads EIIte�BpfLw�'e•Deirelopme •;lric. <br /> Rlcce�:Heatlr�g•an_•Goolins 1Nooddale�Fi�anl��Rig,ht:t•Jnit <br /> � Mdo�rer M 55�4 .P e�2• <br /> 7"otal Buildin Summa Loads <br /> Dompvn� t rea �er� Lat en 'R'ot�l <br /> D I.�i,s � i� <br /> 4A�-d:Glazing-Double pane low-e(e=Q.20 or less), 104.$ 2,939 0 2,411 2,419 <br /> high perfarrr�ence, siiding glass door, e=0.05 on <br /> surface 2,any frame, outdoor insect screen with 50� <br /> coverage, u value 0.33,SHGC 0.33 <br /> Andersen:Glazing-ope�able wir�dow,wood sash, u-value 224.8 5,548 0 5,930 5,930 <br /> 0.29, SHGC 0.32 <br /> Andersen:Glazing-operable window,virood sash,outdoor 58 1,430 0 1,757 1,757 <br /> insect screen with 5096 coverage, u-value 0.28, <br /> SHGG 0.32 <br /> 11 N: Door-AAetat-Polystyrene Core 44.a 1,321 0 373 373 <br /> 12F-Osw:Wal!-Frame, R-21 in&u�ation in 2 x 6 stud 1372.9 7,585 0 1,187 1,187 <br /> cavi#y, no board insulation,siding finish,wood studs <br /> 12F2-Obw:Walf-Frame, R-34 closed cell 2 Ib. spray foam 832.7 3,882 0 39A 394 <br /> insulation in 2 x 6 stud cavity, no board insulation, <br /> brick finish,woad studs <br /> 1580r10sf-8:Wall-Basement;�, R-10 hoard insulation to 361 1,69$ 0 45 45 <br /> floor, no interior finish,8'floor depth <br /> 1564-10sf-4:Wall-Basement, , R-10 board insulation to 184.5 755 0 0 0 <br /> floor, no interfor finish,4'floor depth <br /> 16&50: RooP/Ceiling-Under Attic with Insulation on Attic 1705 2,899 0 1,637 1,637 <br /> Flppr(also use for Knee Wells and F�rtition <br /> Cellings),Vented Attic, No Radiant S�rrier, Dark <br /> Asphalk Shingles ar Dark Metal,Tar and Grave[or ' <br /> Membrane, R-50 insulation <br /> 21A 32: F1oar-Basement, Concrete slab,any thickness,2 1705 2,899 0 0 0 <br /> or more feet below grade, no lnsulation below floor, <br /> an�oor cover,shortest side of floor sleb is 32'wide <br /> Subtotals for structure: � 30,956 0 13,734 13,734 <br /> People: 5 1,000 1,150 2,150 <br /> �quipment: 722 6,387 7,109 <br /> Lighting: 0 0 0 <br /> Duciwork: Q 0 0 Q <br /> Infiltrefion:Winter CFM:45,Summer CFAfl:22 4,06U 347 310 $57 <br /> Vantilation:Winter CFM: 128, $ummer CFM: 128 4,645 1,985 714 2,696 <br /> Exhaust:Winter CFM: 128, Summer CFM:128 <br /> Humidification(Winter)7.93 gaUday: 2,909 0 4 Q <br /> AED Ex�ur�ion: _._0.....__- 0 3,741 3,7�F1_ <br /> Tota)�uilding Load Tatals: 42,570 4,054 26,033 30,087 <br /> ��. r�s .� ;, <br /> Total Building Supply CFM: 1,186 CFM Per Square ft.: p.34g <br /> Square ft. of Room Area: 3,410 <br /> Volume(fte): 26,852 <br /> .u1 n� ��ads � <br /> Total Heating Required Including Ventilation Air. 42,57Q Btuh 42.b70 MBH � <br /> � � Total Sensible Gain: 26,033 Btuh 87 °6 <br /> Total La#�nt Gain: �,05�F Btuh 13 % <br /> Total Cooling Required Inciuding Ven#ilation Air. 30,087 Btuh <br /> N' , . . <br /> Rhvac is an ACCA approved Manua[J and Manuel d computer program. � <br /> Calculations are perfortned per ACCA Manual J 8th Edftlon,Version 2,and ACCA Manual D. <br /> All computed resulks are esNm2tes as building use and weather may vary. <br /> Be sure ta select a unit that meets both s�nsible and Iatent loads according to the manufacturers performanca data at <br /> your design conditions. <br /> C:1...IWooddale Hogan II r�ght uni#.rh8 Tuesdey,June 27, 2017, 1:53 PM <br />