Laserfiche WebLink
�ou��cu i i i 4:14 KICCaf f1@ailfl9 �A�l`.i/54 u131 P.003l008 <br /> " � Rhvac-�Resi�iaritt 1:8 U9ht:C'omme�clsl�NVA'�4oads EIIte�S'oftwar'�'e'�ey�loj�men#,Inc. <br /> ' Ricaar Haeting: nd�oaling 1�Vooddale Hogan�tl�LatFtJnit; <br /> Atldoirer, MN �Q4 Pe s <br /> Tota!Building Summary �.oads <br /> "�'er�por�ent Area �en � l.a �er� 1 <br /> ��� �.�o, a C �� �in <br /> 4A-S-d: Glazing-aouble pane low-e{e=0.20 or less), 9�4.$ 2,939 0 2,411 2,a11 <br /> high perFormartce,sliding glass door, e=0.05 an <br /> surface 2,any frame,ouhioor insect acreen with 50� <br /> coverag�,u-value 0.33,SHGC 0.33 <br /> Andersen: Glazing�perable window,wood sash, u-value 272.8 6,726 0 7,387 7,397 <br /> 0.29, SHGC 0.32 <br /> Andersen:Glazing-operable window,wood sash,outdoor 58 1,43D 0 1,757 1,757 <br /> inseot screen with 50%co�erage, u value 0.29, <br /> SHGC 0.32 <br /> 11id: Door-Metal-Polystyrene Core 44.4 1,321 0 373 373 <br /> 12F-0sw:W811-Frame, R-21 insulation in 2 x 6 stud 1324.8 7,319 0 4,146 1,146 <br /> cavity,no board insulation,siding finish,wood studs <br /> 12F2-0bw:Wall-Frarne, R-34 closed cell 2 Ib.spray foam 832.7 3,892 0 394 394 <br /> insulation in 2 x 6 stud cavity, no board insuletion, <br /> brick finish,wood studs <br /> 1550-10af-8_Wall-Basement, , R-10 board insulation to 361 4,898 0 45 45 <br /> floor, no Interior flnish,8'ffoor depth <br /> 1580-10sf�:Wal!-Basement, , R-10 boerd insulsdon to 164.5 755 0 4 0 <br /> floor, no interior finish,4'flopr depth <br /> 168-50: Roof/Ceiling-Under Attic with lnsulation on Attic 9705 2,899 8 1,637 1,637 <br /> Fidor(also use for Knee Walls and Partition <br /> Ceilings),Vented Attie, No Radiant Banier, Dark <br /> Asphalt Shingles or Dark Metal,Tar and Gravel or <br /> Membrane, R-50 fnsulation <br /> 21A-32: Floor�Basement,Concret�slab,any thickness,2 1685 2,865 0 Q p <br /> or more feet below grade, no insulation below floor, <br /> any floor cover,shortest side of floor slab is 32'wide <br /> 20P-30: Floor-Over open crawl space o�garage, Passive, 20 60 0 6 � <br /> R-30 blanket Insul3tioa,any cover ' <br /> Subtotala for structure: 31,902^~ 0 15,168 15,166 <br /> People: a 80d 920 1,720 <br /> Equipment: 72Z 6,387 7,909 . <br /> Lighting: 0 p � <br /> , Ductwork: 0 0 0 0 <br /> Infiltration: Winter CFM:45, Summer CFM:22 4,039 345 308 853 <br /> Ventilatian:Winter CFM: 128, Summer CFM: 128 4,645 1,985 710 2,596 <br /> Exhaust:Winter CFIIA: 128, Summer CFM: 128 <br /> Humid�cation�nter)7.92 gaUday: 2,505 0 0 0 <br /> A�p Excursion: T.,�... � 0 T,�� 2,93Q 2,830 <br /> Total Buildin�Load Tatats: 43,499 3,852 26,422 30,274 <br /> G �� + <br /> Total Building Supply CFM: 1,205 CFNI Per Square ft.: 0.3 5 <br /> Square ft.of Room Area: 3,39D <br /> Vofume{ft�: 26,717 <br /> --�-- � . ..... ... <br /> � _. c�U�� t��d�'-....._. �. . <br /> Total Heating Required Including Ventilation Air. 43,a91 Btuh 43.491 M8H <br /> 7ot�i Sensible Gsin_ 26,422 Btuh 87 � <br /> Total Latent Gain: 3,852 Btuh 13 � <br /> Total Cooling Required Including Ventilation Air_ 30,274 Btuh <br /> ,.Q�& ' <br /> Rhvac is an ACCA�pproved Manusl J and Manual D ccmputer program. <br /> Calculations are perFormed per ACCA RAanual J Sth Edition,Version 2,and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to aelect a unit that meets both sensible and latent loads according ta the manufacturec's perFormance data at <br /> yaur design conditians, <br /> C:1...�Wooddale Hogan II teft unit.rh9 Tuesday, June 27,2017, 1:52 PM <br />