My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Re: backwater valve
Orono
>
Property Files
>
Street Address
>
S
>
Spruce Place
>
1270 Spruce Place- 08-117-23-32-0013
>
Correspondence
>
Re: backwater valve
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:43:45 PM
Creation date
3/11/2019 1:41:57 PM
Metadata
Fields
Template:
x Address Old
House Number
1270
Street Name
Spruce
Street Type
Place
Address
1270 Spruce Pl
Document Type
Correspondence
PIN
0811723320013
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r � <br /> Subp. 4. Slaughter houses. Slaughtering and dressing room 4715.1160 BACKWATER VALVES. <br /> drains shall be equipped with separators or interceptors approved <br /> by the administrative authority,which shall prevent the discharge Subpart 1. Where used. Drainage piping serving fixtures that aze <br /> into the drainage system of feathers, entrails, or other material ��ated below the elevation of the curb or property line at the poinf <br /> likely to clog[he drainage system. where the building sewer crosses under the curb or property line, <br /> and above the crown level of the main sewer,shall drain by gravity <br /> STAT AUTH:MS s 326.37 to 326.45 into the main sewer,and shall be protected from back flow of sew- <br /> 4715.1140 VENTING OF INTERCEPTORS age by installing an approved backwater valve,and each such back- <br /> water valve shall be installed only in that branch or section of the <br /> AND SEPARATORS. drainage system which receives the discharge from fixtures located <br /> below the elevation of the curb or property line. <br /> Interceptors and separators shall be so designed that they will not <br /> become airbound if closed covers are used. Each interceptor or FuRher,in every building hereafter erected or remodeled so that <br /> � separator shall be properly vented. . the erection or remodeling creates a new dwelling use which is <br /> located below the elevation of the point where the building sewer <br /> STAT AUTH:MS s 326.37 to 326.45 crosses under the curb or property line, all fixtures installed be- <br /> low such point shall be connected to a separate branch drain. Each <br /> 4715.1150 MAINTENANCE OF such branch drain shall be protected by an approved backwater <br /> INTERCEPTORS AND SEPARATORS. valve and a gate valve. The gate valve shall be located on the <br /> sewer connection side of the backwater valve. <br /> Interceptors and separators shall be maintained in efficient oper- � <br /> ating conditiomby periodic removal of accumulated grease,scum, FuRher,the backwater valve and gate valve may be waived by the <br /> oil,or other floating substances, and solids,deposited in the in- administrative authority whenever the sanitary sewer dces not re- <br /> terceptor or sepazator. ceive any storm water drainage and the building is located at a suf- <br /> ficient height above the public sanitary sewer so flooding by backflow <br /> Each interceptor and separator shall be so installed that it is readily Will not occur,in the opinion of the administrative authority. <br /> accessible for removal of cover, servicing, and maintenance. If Subp.2. Construction of backwater valves. Backwater valves <br /> installed substantially below grade a manhole with flush man- shall be constructed so that a mechanical seal a amst backflow <br /> hole cover should be provided. g <br /> will be provided. Backwater valves shall have all balls or bearing <br /> STAT AUTH:MS s 326.37 to 326.45 ' parts of noncorrodible material and shall have bolted covers and <br /> be readily accessible for cleaning. <br /> Subp. 3. Venting of backwater valves. Where the installation <br /> and operation of backwater valves interfere with the proper ven- <br /> tilation of the plumbing system, additional vents shall be pro- <br /> vided so as to assure adequate ventilation of the plumbing system <br /> when the backwater valves are in a closed position. <br /> Subp.4. Accessibility of backwater valves. Backwater valves <br /> shall be installed so their working parts will be readily accessibie <br /> for service and repairs. If installed substantially below grade a <br /> manhole with flush manhole cover shall be provided. <br /> STAT AUTH: MS s 16B.62;326.37 to 326.45 <br /> HIST: 19 SR 590 <br /> 30 <br />
The URL can be used to link to this page
Your browser does not support the video tag.