r � <br /> Subp. 4. Slaughter houses. Slaughtering and dressing room 4715.1160 BACKWATER VALVES. <br /> drains shall be equipped with separators or interceptors approved <br /> by the administrative authority,which shall prevent the discharge Subpart 1. Where used. Drainage piping serving fixtures that aze <br /> into the drainage system of feathers, entrails, or other material ��ated below the elevation of the curb or property line at the poinf <br /> likely to clog[he drainage system. where the building sewer crosses under the curb or property line, <br /> and above the crown level of the main sewer,shall drain by gravity <br /> STAT AUTH:MS s 326.37 to 326.45 into the main sewer,and shall be protected from back flow of sew- <br /> 4715.1140 VENTING OF INTERCEPTORS age by installing an approved backwater valve,and each such back- <br /> water valve shall be installed only in that branch or section of the <br /> AND SEPARATORS. drainage system which receives the discharge from fixtures located <br /> below the elevation of the curb or property line. <br /> Interceptors and separators shall be so designed that they will not <br /> become airbound if closed covers are used. Each interceptor or FuRher,in every building hereafter erected or remodeled so that <br /> � separator shall be properly vented. . the erection or remodeling creates a new dwelling use which is <br /> located below the elevation of the point where the building sewer <br /> STAT AUTH:MS s 326.37 to 326.45 crosses under the curb or property line, all fixtures installed be- <br /> low such point shall be connected to a separate branch drain. Each <br /> 4715.1150 MAINTENANCE OF such branch drain shall be protected by an approved backwater <br /> INTERCEPTORS AND SEPARATORS. valve and a gate valve. The gate valve shall be located on the <br /> sewer connection side of the backwater valve. <br /> Interceptors and separators shall be maintained in efficient oper- � <br /> ating conditiomby periodic removal of accumulated grease,scum, FuRher,the backwater valve and gate valve may be waived by the <br /> oil,or other floating substances, and solids,deposited in the in- administrative authority whenever the sanitary sewer dces not re- <br /> terceptor or sepazator. ceive any storm water drainage and the building is located at a suf- <br /> ficient height above the public sanitary sewer so flooding by backflow <br /> Each interceptor and separator shall be so installed that it is readily Will not occur,in the opinion of the administrative authority. <br /> accessible for removal of cover, servicing, and maintenance. If Subp.2. Construction of backwater valves. Backwater valves <br /> installed substantially below grade a manhole with flush man- shall be constructed so that a mechanical seal a amst backflow <br /> hole cover should be provided. g <br /> will be provided. Backwater valves shall have all balls or bearing <br /> STAT AUTH:MS s 326.37 to 326.45 ' parts of noncorrodible material and shall have bolted covers and <br /> be readily accessible for cleaning. <br /> Subp. 3. Venting of backwater valves. Where the installation <br /> and operation of backwater valves interfere with the proper ven- <br /> tilation of the plumbing system, additional vents shall be pro- <br /> vided so as to assure adequate ventilation of the plumbing system <br /> when the backwater valves are in a closed position. <br /> Subp.4. Accessibility of backwater valves. Backwater valves <br /> shall be installed so their working parts will be readily accessibie <br /> for service and repairs. If installed substantially below grade a <br /> manhole with flush manhole cover shall be provided. <br /> STAT AUTH: MS s 16B.62;326.37 to 326.45 <br /> HIST: 19 SR 590 <br /> 30 <br />