Laserfiche WebLink
„�1-�d,s " �x s'a 3 z" � �i� <br /> . � l���z�5 �o�k��� 3 �. z= r��r <br /> , <br /> �� <br /> ,�,�.�I�S'tlgB�lOt1 ciTY oF oRorro <br /> SEPTIC PE IT PL EVIEW <br /> & Design�NC INSPECTOR ' <br /> ����-� DATE� 1 _PERMITNO. ,0 ,o�07 <br /> � APPROVF.D AS SCA:�tf7TED <br /> September 14,2016 C] APPROVGD WlTH CORRFCTIOKS AS 1�OT£D <br /> [� NOT APPROVED-CORRECT&RESUB�i1T <br /> Tl�.rsc commaits nrc Por your information. All work shall bc done <br /> Mr. Mrs.Robert&Caroline Fullerton in fuli compli:ince with ull upnlicablc scptic and zoning cudc. <br /> 1135 SpI'121g Hlll RoaC� R;quircmcnts including itcros not specifically notcd in this rcview. <br /> Wayzata,MN 55391 r:��!.���rF�is r>�.,���sE.�r���srr��:nT n�[.1�i�irs <br /> Re: Septic Redesign <br /> Dear Mr.Mrs.Fullerton, <br /> Thank you for the opportunity to work with you on the redesign of you septic system.As you know,the soil treatment system(drain <br /> field)for the existing system does not meet current code; and to allow for future planning, it was decided to relocate the soil treatment <br /> system(SSTS)to a different location on your property. <br /> It was elected to locate the system to a positon below the house in the open field(see Figures 1 &2). Due to soil conditions,the <br /> system will need to be a mound system.The redesigned system will be configured as follows: <br /> 1. The existing SSTS will be abandoned in place according to current septic code. <br /> 2. The three 1,000 gallon tanks of your system are all watertight according to the recent septic inspection. <br /> 3. The third septic tank currently being used as a pump tank will be converted to a septic tank which will require a baffle to be <br /> installed at its outlet. <br /> 4. The piping to the old SSTS will be abandoned in place. <br /> 5. New piping to the bottom of the slope adjacent to the tank will be installed to code. <br /> 6. A surge block(large concrete reinforcement to stabilize the pipe at its bottom)will be installed prior the discharge point in <br /> the new tank. <br /> 7. A new pump tank will be installed near the foot of the slope. This tank can be either poly or concrete.It must have the proper <br /> fitting and be on the MPCA approved tank list. <br /> 8. The City of Orono has requested a 1,250 gallon tank which will provide adequate storage for one(1)day of water use. <br /> 9. A pump with the proper characteristics will be installed in this tank to feed the mound. <br /> 10. The pump should be operated on a"on demand”basis. <br /> 1 L The mound will be installed to code and placed on the contour. <br /> 12. Because of required setbacks,the lower edge of the mound will be at approximately the lone tree in the open field. <br /> 13. The electrical box and irrigation lines will need to be relocated to accomplish this. <br /> 14. The disturbed areas will be either seed or sodded as you request. <br /> Thank you for your time if you have any questions please feel free to contact me at 651-260-3783 or at <br /> pbrandt(�a,soilinve sti�ations.us. <br /> I hereby certify that this plan, document,or report was prepared by me or under my direct supervision and that I am a duly Licensed <br /> Professional Soil Scientist under the Laws of the state of Minnesota.License 30007,Date: September 14,2016 <br /> Paul Brandt PSS, <br /> � �� <br /> Professional Soil Scientist THIS SYSTEM IS DESIGNED FOR <br /> ,,,�BEDROOMS. ANY INCREASE tN NUMBER <br /> OF BEDROOMS INVAUDATES THIS DESiGN. <br /> pbrandtnn,soilinvestigations.us �651.260.3783 �320.260.8874 �www.soilinvestigations.us <br /> 2809 78'i'Avenue North�Brooklyn Park,MN 55444 <br />