My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2005-P09160 - septic
Orono
>
Property Files
>
Street Address
>
S
>
Spring Hill Road
>
0745 Spring Hill Road - 36-118-23-21-0003
>
Septic
>
2005-P09160 - septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:02:07 PM
Creation date
3/6/2019 12:28:15 PM
Metadata
Fields
Template:
x Address Old
House Number
745
Street Name
Spring Hill
Street Type
Road
Address
745 Spring Hill Road
Document Type
Septic
PIN
3611823210003
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, .. � E-3 . <br /> :�� <br /> • manifQid pipe <br /> �-- � �f pipe from pumR <br /> ;;: <br /> end cop � <br /> ♦ <br /> �`�. <br /> olternate location <br /> of pipe from pump <br /> Figure E-1: Manifold Located at End of Syst�m <br /> ' distribution manifold to the end of the lateral.A c nter manifold <br /> is preferred because it minimizes pipe sizes. Figures E-1 and E-2 <br /> illustrate two possible manifold positions. <br /> The hole spacing should be less than five feet*. The higher the <br /> hole density, the more uniformly the wastewater is distributed. � <br /> Figure E-2: Manifold Locoted end cap <br /> in the Center of the System . <br /> � manifold pipe <br /> '., �j �/ <br /> alter�ti on <br /> �� of pipe fr�m pump <br /> '�o .� ► <br /> �,5 � pipe from pump � � �/ � <br /> � 3 �� <br /> Perforations should be spaced no farther apart than one half of *7080.0150, 3E • <br /> the rock layer width, or five feet, whichever is less. <br /> The number of perforations may be adjusted slightly to match <br /> the available pump capacity and head. The holes should be <br /> � staggered between adjacent laterals, <br /> if possible.The last perforation <br /> should be driUed in the end cap of ���"�'��9eotextue�,-�,,�,;�;�,4;ti,;�;� :: <br /> t�te lateral, at least o�foot from t11e quarter-inch pertorations spaced 3'apart minimum <br /> edge of the rock layer(see Figure E-3 2~or rxk <br /> for specifications). This final �2a <br /> perforation facilitates venting as the , �"ot rock • . <br /> pipe Eills. <br /> perfo�ation sizin :7/32" <br /> � Select a hole diameter, for systems pertoration spac ng: y _ � <br /> ser�ting single-family homes, l/4- Figure E-3: Lateral End Specs <br /> inch holes are sufficient and � <br /> � X � S � ` " , �i� S� ` :. <br /> �a <br /> � ��� <br />