My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info
Orono
>
Property Files
>
Street Address
>
S
>
Spring Hill Road
>
0745 Spring Hill Road - 36-118-23-21-0003
>
Septic
>
septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:02:10 PM
Creation date
3/6/2019 12:18:02 PM
Metadata
Fields
Template:
x Address Old
House Number
745
Street Name
Spring Hill
Street Type
Road
Address
745 Spring Hill Road
Document Type
Septic
PIN
3611823210003
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF ORONO �O� <br /> Mimicipal Offices O O <br /> Post Office Box 66 <br /> Crystal Bay, MN 55323-0066 a � ON—SITS SEWA(3E TREAT�ENT <br /> r�,, � INSPECTION REPORT <br /> '�� G~ <br /> '� <br /> 9kEsHo�' <br /> Owner: J=rIQI�I l���mq�, Address: / . 1� �SlQ�eI1CC <br /> Permit �'s: Dates: �'" ontractors: � �. <br /> City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regutar besis. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the category <br /> checked below. <br /> (This is f� an existing system [ ] new construction) <br /> SYSTEM CONF�tMITY (1-3): <br /> 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City <br /> Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input <br /> without discharging any pollutants into ground or surface waters. <br /> 2 "CONFORMING STSTEM"-A system which does not meet all the location, design, and construction standerds of the <br /> current City Codes, but was installed according to the code in effect at the time of installation, and which <br /> is operating satisfactorily by treating and disposing of the entire current sewage input without discharging <br /> any pollutants into gro�d or surtace waters. <br /> 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodptain; any <br /> system which mey or mey not meet all the location, design, and construction standards of the current City <br /> Codes and which is tailing for any reason; and an s st ' saturated soil or sand <br /> between the distribution device and the limiting so� c aracteristics. �d 'U ''''� Y 1a <br /> �(The limiting soil characteristic has or [ ] has not been identifi a this time. If the limiting soil <br /> characteristic has not been ident ie , this classification may be subject to revision.) <br /> TANK CONDITION (5-10): '�' <br /> � inspection indicates: <br /> Pumpout not needed at this time. <br /> 6 Soltds accumulation in tanks indicates they should be punped out this year to help prevent future problems. <br /> 7 Solids accumulation in tanks is at a critical level. Yanks should be punped out as soon as possible. <br /> 8 System is discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface dischar�e. <br /> 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4�� dia. pipe) must be installed in each <br /> tank at next punpout. If tanks have not been punped out within the last three years, they should be punped <br /> out now. <br /> 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accunulation). <br /> If tanks have not been ptanped out within the last three years, they should be punped out now. <br /> DRA[NFIELD CONDITION (11-14): <br /> D�field inspection indicates: <br /> 1 Drainfietd is dry, no surfacing evident. <br /> 2 Same evidence of surfacing, not critical yet. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City lnspector <br /> immediately. Repairs must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> LIMITING SITE fACTORS (sloce.setbacks.etc.): <br /> POTENTIAL FOR SYSTEM FAILURE (decends on soils,water table,etc.): <br /> �corsr� Ts: - - d <br /> i s - '� <br /> Date o ns ection • �°��• <br /> p p System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, be advised that this report does not guarantee or certify that an existing system will continue to function <br /> properlyi but is merely an opim on of the adequacy of the system under current conditions based on the available <br /> information. <br /> This report must be kept on the premises with the system locetion and pumping records. <br /> WHITE COPY/Inspectors File YELLOW COPY/Homeow�er <br />
The URL can be used to link to this page
Your browser does not support the video tag.