Laserfiche WebLink
��o�� � <br /> � . � <br /> ; o o� <br /> ,, <br /> : ':` C ITY of ORONO <br /> �� ,,},� �:,:: ,, � . <br /> � � � : r r���� � . <br /> ,� '�i; .�. s,;i. ,, ��C,, . Municipal Offices <br /> :;±;�.. . <br /> '�,t� , �.{._'�'''�,:`;'�G Street Address: �15ot-a49-y6o 0 Mailing Address: <br /> '9k��p4' 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> 6�s s �: ,�, �t� <br /> To Current Owner: Address: �`I � <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> YSTEM CONFORMIT'Y 1-3 : � <br /> 1 "CODE SYSTEM"An ISTS which meets all the location,design and construction standazds of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standazds of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requ'uement for systems installed 1996 or earlier,and <br /> which is not failing or an inm,ir,ent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction stand�rds of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand beriveen the distribution device and the limiting soil characterisdcs. <br /> TANK CONDITION(5-7): o <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 6�Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped 6� ��—� � ). <br /> Make sure septic tanks are pumped throu¢h manhole and not throush white inspection aipes. This allows for the proper <br /> cleaning Keep water softner and iron filter dischar¢e out of septic svstem to prolong life of drainfield. Ask aumaer to test <br /> alarm float to verifv alarm is still workine in vour house. The alarm warns owner that seatase is about to backua into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> D INFIELD CONDITION 8-10 : Y <br /> 8 Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfieid is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: ���:��<c�� �o�1CS �� � �vri(� �e��-�— ��k� <br /> S,, �.�1 r �c�5''_ <br /> � b - �—a� �� <br /> Date of[nspection Matt Bolterman - Septic System Inspector <br /> Not�: in the even[[hat this inspection report is used to satisf� the requirements for a mortgage or uther transfer of'propert�. be advised thet this report dues <br /> nut guarunlee or certih that an e�istin¢ 5�•stem ���ill continue tu Ilmction properl�. but is merel� an opinion of the adequac�• oFthe s�stem Lmder currcnt <br /> �un�itiuni based on the avail�blc inl�nnation. <br />