Laserfiche WebLink
. CARSON CALC <br /> ENERGY CALC CONTINUED <br /> CEIUNGSJROOF � , <br /> DETERMINE SPECIRIC AREAS FROM PLAN: <br /> TOTAL EXPOSED ROOF/CEILING AREA(SAME AS#2 ABV) = 1892.00 SF <br /> J.,TOTAL SKYLIGHT AREA = SF <br /> K. TOTAL ROOF FRAMING AREA 10%+/- = 189.20 SF <br /> L. TOTAL NET INSUL ROOF/CLG @ R50+ = 1702.80 SF <br /> DEfERMINE VALUE OF EACH ROOF/CEILJNG SEGMENT <br /> j. 0 x "U" = 0.00 <br /> . k. 189.2 x "U" 0.022 = 4.16 <br /> L 1702.8 x "U" 0.019 = 32.35 <br /> 4.TOTAL VALUE ROOF/CEILING = 36.52 <br /> ITEM#2 FROM ABOVE = 49.19 <br /> IF TOTAL OF#4 IS THE SAME AS,OR LESS THAN#2,THE INTENT OF SBC 6006(C)1 HAS BEEN MET. <br /> ALTERNATE BUILDING ENVELOPE DESIGN <br /> TO U1ILJZE THE TOTAL ENVELOPE SYSTEM METHOD,THE VALUES ESTABLISHED BY THE SUM OF ITEMS <br /> #3 AND#4�HALL NOT BE GREATER THAN THE SUM OF ITEMS#1 AND#2. <br /> #1. 533.83 +#2. 49.192 = 583.02 <br /> #3. 517.2141 +#4. 36.516 = 55,3.73 <br /> Variance from statute: + 29.29 <br /> (+VALUE ACCEPTABLE) <br /> (-VALUE UNACCEPTABLE) . <br /> , <br /> Page 2 <br />