Laserfiche WebLink
Property address: 3010 Somerset Lane Inspector Initiais/Date I 7/24/2018 <br /> � (mm/dd/yyyy) <br /> 4. Soil Separation - Compliance component#4 of 5 <br /> Date of instailation: 7/24/2018 ❑ Unknown Verification method(s) <br /> (mMdd/yyyy) Soil observation does not expire. Previous soil observations by two <br /> independent parties are sufficient,unless site conditions have been <br /> ShorelandlWellhead Protectlon/Food, ❑ Yes � No altered or local requirements differ. <br /> beverage,lodging? <br /> Compliance Criteria: <br /> For systems built prior to Apri11, 1996,and � Yes � No � Conducted soil observation(s)(Attach boring logs) <br /> not located in Shoreland or Wellhead � Two previous verifications(Attach boring logs) <br /> Protection Area or not serving a food, <br /> beverage or lodging establishment. ❑ Not applicable(Holding tank(s),no drainfield) <br /> � Unable to verify(See Comments/Explanation) <br /> Drainfield has at least a two-foot vertical � Other(See Comments/Explanation) <br /> separation distance from periodically Comments/Explanation: <br /> saturated soil or bedrock. <br /> New system verification done at review <br /> Non-performance systems built April 1, � Yes ❑ No <br /> 1996,or later or for non-performance <br /> systems located in Shoreland or Wellhead <br /> Protection Areas or serving food,beverage <br /> or/odging establishment. <br /> � <br /> Drainfield has at least a three-foot vertical Indicate depths or elevations <br /> separation distance from periodically <br /> saturated soil or bedrock. A.Bottom of distribution media <br /> Experimental", "Other"or"Performance" ❑ Yes ❑ No <br /> systems built under pre-2008 Rules, Type IV B.Periodically saturated soil/bedrock <br /> or V systems built under 2008 Rules <br /> (7080.2350 or 7080.2400(Advanced C.System separation <br /> Inspector License required) <br /> Drainfield meets the designed vertical <br /> D.Required compliance separation' <br /> separation distance from periodically <br /> saturated soif or bedrock. `May be reduced up to 15 percent if allowed by Local <br /> Ordinance <br /> Any "no"answer above indicates the system is <br /> failing to protect groundwater. <br /> 5. Operating Permit and Nitrogen BMP - Compliance component#5 of 5 ❑ Not applicable <br /> Is system operating under an Operating Permit? ❑ Yes ❑' No If"yes",A below is required. <br /> Is the system required to empioy Nitrogen BMP? ❑ Yes � No If"yes", B below is required. <br /> BMP=Best Management Practice(s)specified in the system design. <br /> If the answer to both quesfions!s "no'; this section does not need to be comp/eted. <br /> Compliance Criteria: <br /> a. Operating Permit number: Yes No <br /> Have the Operating Permit requirements been met? <br /> b. Is the required nitrogen BMP in place and properly functioning? Yes No <br /> Any "no"answer above indicates Noncompliance <br /> Upgrade Requlrements(Minn.Stat§115.55). An imminent threat to public heaith and safety(ITPHS)must be upgraded,replaced,or its use discontinued within ten months of <br /> receipt of this notice or within a shorter period if required by bcal ordinance. If the system is failing to protect groundwater,the system must be upgraded,reptaced,or its use <br /> discontinued within the Gme required by bcal ordinance. If an existing system is not failing as defined in law,and has at least Mro feet of design soil separation,then the system need <br /> not be upgraded,repaired,replaced,or its use discontinued,notwithstanding any bcal ordinance that is more strict. This provision does not appy to systems in shoreland areas, <br /> Wellhead Protection Areas,or those used in connection with food,beverage,and lodging establishments as defined in law. <br /> wq-wwists431c • 6/4H4 • www.pca.state.mn.us •Availa6le in altemative formats • 651-296-6300 • 800-657-3864 • TTY 651-282-5332 or 800-657-3864 Page 3 of 3 <br />