NOTE: <br /> CONTRACTOR MAY SUBSTITUTE#5 BARS <br /> FOR#6 BARS PROVIDED THE FOLLOWING <br /> SPACING REQUIREMENTS ARE MET: <br /> VERTICAL BARS-#5 @ 24"O.C. PROPOSED GRADE <br /> HOOK BARS-#5 @12"O.C. AT TOP OF WALL <br /> FOOTING-#5 @ 12"O.C. <br /> J <br /> J <br /> LL. <br /> � <br /> W <br /> V #6 VERTICAL BARS <br /> z <br /> g @ 3s°o.c. <br /> a <br /> z ` 8"THICK CAST-IN-PLACE <br /> � CONCRETE WALL <br /> Q <br /> � (8)#4 x CONT. HORIZONTAL <br /> in BARS EVENLY SPACED �Q <br /> Cn � <br /> PROPOSED GRADE 2"CLR. <br /> AT FRONT OF WALL� <br /> ,° ' #6 x 6'-2"HOOK 42„ <br /> _ _ _ _ � � ,: .: �_��` BARS @ 18"O.C. <br /> � , _ <br /> 32" <br /> z <br /> � <br /> Q #6 BARS @ 18"O.C. <br /> ih <br /> (4)#4 x CONT HORIZONTAL <br /> BARS EVENLY SPACED <br /> 0 <br /> � <br /> 12"THICK CAST-IN-PLACE ` � `� <br /> � <br /> CONCRETE FOOTING <br /> ����� $�� 3,��� <br /> 5'-0" <br /> � RETAINING WALL SECTION <br /> S2 5'-6"MAXIMUM UNBALANCED FILL <br /> �f> l� —L�(�(_C �p S <br /> ��'� C; Sc;y i �e�S�-� (�+ <br /> I hereby certify that this plan,specification,or report <br /> was prepared by me or under my direct supervision <br /> and that I am License essbnal Engineer <br /> under th ws the o ' n�q a. <br /> �!G__-- <br /> Jason S.Hanlon <br /> Date: 7/11/12 License No. 41941 <br /> o� Project No.: Sheet: <br /> ;�s o WALL SECTION gL 12 03905 <br /> ¢�"rn TRANGSRUD RESIDENCE <br /> dz�,� <br /> N '�� <br /> a N�� 2850 SOMERSET LANE <br /> �—�� Drawn By: M.Weinkauf <br /> = g°f X Drawing Date: 07/10I2012 <br /> & o =a¢ ORONO MN Checked By:J.Hanlon <br /> @ O� LL � <br /> � Last Modifled:07/11l2012 2 of 3 <br />