Laserfiche WebLink
� o� <br /> 0 0 <br /> ' � ��,-� � CITY of �RONO <br /> , , <br /> � �i, �.r��,*�' <br /> �� !�r•��, ����J,,� �� Munkipal Offtces <br /> ��" ��t� G � <br /> \ �-�; ;,��,�►y Street Addreu: Mailina Addreas: <br /> ��,+gg0�" 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> Owner: L/� ���I Address: 160 Smith 7►ve. <br /> Permit #'s: 8714 Dates: 10/8/86 Contractors: IaQl�sid. EaQr. <br /> (This is (� an existing system [ ] new construction) . <br /> SYSTEM COMPLIANCE (1-3) : 3 <br /> 1 Code System: Meets or exceeds current City standards in all respects relating to design, <br /> construction, and location. Appears to be operating properly. <br /> 2 Compliant System: Does not meet all current City standards for new construction, but in <br /> most respects appears to be designed, located, and constructed in accordance with previous <br /> codes and is functioning properly. <br /> � Non-Compliant System: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any system with less than three feet of vertical separation between the bottom <br /> of the drainfield and the saturated soil level. <br /> (The saturated soil lmvel is [/y or is aot [ � ideatified under this septic aystwm. If tha <br /> saturated soil levml is aot ideatified, this classificatioa is subject to reviaioa.) <br /> TANK CONDITION (5-9) : 9 <br /> 5 Pumpout not needed at this time. <br /> 6 Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Znspection risers missing-tanks could not be inspected. If tanks have not been pumped out <br /> within three years, they should be pumped out and risers installed now. <br /> � Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks <br /> have not been pumped out within three years, they should be pumped out now. <br /> 10 one or more tanks are cesspools, which means t e s non-comp ant. <br /> (The taaks ara [ ] or are aot [ ] water tiQht or the coadition is (�] unkaoorn. If the taaks <br /> are aot coafirmed to be watertiQht, thi: clas:ification is subjact tcl reviaioa.) <br /> INFIELD CONDITION (11-14) : 11 <br /> Drainfield is dry, no surfacing evident. <br /> 2 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br /> Contact the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : low <br /> CONIl�IENTS: In order to confirm that your septic system meets Minnesota standards, soil borings <br /> were performed to verify a 3 foot separation between the drainfield and the seasonal water <br /> table. Ths separation is 2 feet and the system is non-compliant. City Codes do not require <br /> repair or replacement of the septic system at this time. <br /> --���� /L <br /> Date of Inspection Sep ic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly, but indicates the operation of the system under current conditions. <br /> Tdephone (612) 473-7357 • FAR 473-0510 <br />