My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info
Orono
>
Property Files
>
Street Address
>
S
>
Smith Avenue
>
095 Smith Avenue - 02-117-23-21-0031
>
Septic
>
septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:10:29 PM
Creation date
2/15/2019 2:15:03 PM
Metadata
Fields
Template:
x Address Old
Address
095 Smith Ave
Document Type
Septic
PIN
0211723210031
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF ORONO �O� <br /> Municipal Offices O O <br /> Post Office Box 66 <br /> Crystal Bey, MN 55323-0066 � � ON—SITE SEWA(iE TREAT�NT <br /> �ti. <br /> INSPECTION REPORT <br /> '��9k o4�G <br /> Es8 <br /> Owner• � Address• � �Sy1)� ti7/�'. <br /> Permit #"s: Dates: /��'�> Contractors:�l;!/1 1(�m� <br /> City ordinance nunber 100 requires that each on-site sewage treatment system in Orono be inspected on a regutar besis. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the category <br /> checked below. <br /> (This is � an existing system [ ] new construction) <br /> SYSTEM CONF�tMITY (1-3): � <br /> 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City <br /> Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input <br /> without discharging any pollutants into ground or surface waters. <br /> 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the <br /> current City Codes, but was installed according to the code in effect at the time of installation, and which <br /> is opereting satisfactorily by treating and disposing of the entire current sewage input without discharging <br /> any pollutants into ground or surface waters. <br /> "NON-CONfORMING SYSTEM"-A prohibited system; a system located within a designated 700-year floodplain; any <br /> system which �y or may not meet all the location, design, and construction standards of the current City <br /> Codes and which is failing for any reason; .and eny.system with less than 3 feet of unsaturated soil or sand <br /> between the distribution device and the lim�ting soil characteristics. <br /> (The limitin� soil characteristic [ ] has or (,� has not been identified at this time. If the limiting soil <br /> characteristic has not been identified, this dlassification may be subject to revision.> <br /> TANK CONDlTION (5-10): � <br /> Tank inspectton i te <br /> 5 P ut no his time. <br /> � So�lds in tanks indicates they should be out this year to help prevent future roblems. <br /> lids accumulation in tanks is at a critical leve a soon as 'b . <br /> ' ' e. an s must punped out within 48 hours to e imina e sur 8ce dischar�e. <br /> 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" die. pipe) must be installed in each <br /> tank at next puipout. lf tanks have not been pun�ed out within the last three years, they should be punped <br /> out now. <br /> 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accunulation). <br /> If tanks have not been ptmped out within the last three years, they should be punped out now. <br /> DRAINFIELD CONDITION (11-14): <br /> Drainfield inspection indicates: <br /> 71 Drainfie[d is dry, no surfacing evident. <br /> Same evidence of surfacing, rwt critical yet. <br /> w <br /> 3 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immedi Repairs must be completed within 90 days. <br /> 14 Drain ie extent and condition unknown. <br /> LIMITING SITE FACTORS Cslooe.setbecks.etc.): <br /> POTENTIAL FOR SYSTEM FAILURE (decends on soils.water table,etc.): —��� <br /> COMMENTS: <br /> Date of nspection ep ic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, be advised that this report does not guarantee or cert�fy thet an existing system will continue to function <br /> properlyi but is merely an op�m on of the adequacy of the system under current conditions based on the available <br /> information. <br /> This report must be kept on the premises with the system location and pimping records. <br /> WHITE COPY/Inspectora Fite YELLOW COPY/Homeowner <br />
The URL can be used to link to this page
Your browser does not support the video tag.