Laserfiche WebLink
� <br /> ,�'Q��.1� � <br /> //� `� <br /> ,. <br /> i� O��; <br /> �� Y��� �- - �I CIT� of URONO <br /> 1� �s��i'��'r.�'� �y �� <br /> ': 1'a �x� � .c � � r <br /> r � ���� ,; lj MunicipalOffices <br /> ���'��'� � Y� f'::, ! �,�. <br /> ` � '; � � ;�;���'��`�`' G,� Street Address: °15a-�4q-y6o O Mailing Address: <br /> �`�J(�Hp'g'�.' 2750 Keliey Parkway P.O. Box 66 <br /> -_-� Orono, MN 55356 Crystal Bay, MN 55323•0066 <br /> To Current Owner: Address: �� s r'"'� �v � <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY (1-31: � <br /> 1 "CODE SYSTEM"An ISTS which meets all the location,dcsign and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An LSTS which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requ'vement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an imminent threat to public health or safety. <br /> �31 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> `� or may not meet all the location,design,or construction stanc�rds of the cuaent Orono Municipal Code and which is failing for any <br /> raason;and any ISTS with less than three feet of unsaturated soil or sand between the distriburion device and the limiting soil characteristics. <br /> TANK CONDITION(5-7): <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this yeaz (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped )• <br /> Make sure seatic tanks are oumaed throush manhole and not throu¢h white insaection aipes. This allows for the aroaer <br /> cleaning Keea water softner and iron filter dischar2e out of septic svstem to arolon¢life of drainfietd. Ask aumper to test <br /> alarm float to verifv alarm is still workine in vour house. The alarm warns owner that seataee is about to backun into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> D INFIELD CONDITION 8-10 : <br /> 8 Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 9U days. <br /> coNtNt�vTs: S �� �- �•k '� bca�ce�. a� ;� �„ � n,,.,,;��..�- 1.eg�r�, <br /> ('- b� , `��J c�c���'r �oc�nt�.i- '1'o C.�-y SCwcr �t' �i^� -o$� <br /> �u --�,--o�-4 ��� �.. <br /> Date of Inspecrion Matt Bolterman- Septic System Inspector <br /> Note: In the event that this inspectioa report is used to sarisfy the requirements for a mortgage or other transfor of property,be advised that this report does <br /> not guarantee or certify that an existing system will continue to functioni properly, but is metely an opinion of the adequacy of the system under curnnt ' <br /> .......1:.:......L..,..sA�...t6o'oa�ailahlr infnrmatinn � � � . � � . � � <br />