My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info
Orono
>
Property Files
>
Street Address
>
S
>
Smith Avenue
>
040 Smith Avenue - 02-117-23-21-0002
>
Septic
>
septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:10:20 PM
Creation date
2/15/2019 12:28:10 PM
Metadata
Fields
Template:
x Address Old
Address
040 Smith Ave
Document Type
Septic
PIN
0211723210002
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. �°� <br /> CITY OF ORONO O O <br /> Municipel Offices <br /> Post Office Box 66 <br /> Crystal Bay, MN 55323-0066 � � ON—SITE SEWAaE TREAT!lENT <br /> INSPECTION REPORT <br /> ti <br /> Fv <br /> '�' G <br /> �9kEs8o�'� <br /> Owner• �l".Tf,��lfwbl�� Address: �71'� S/77l ft'i/1F'• <br /> � <br /> Permit #'s: Dates: '^ Contractors: ii/�K�Y�G,.Y� <br /> City ordinance nunber 100 requires that each on-site sewage treatment system in Orono be inspected on a regular besis. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the category <br /> checked below. <br /> (This is [79. an existing system [ ] new construction) <br /> SYSTEM CONFORMITY (1-3): � <br /> 1 "CODE SYSTEM��-A system which meets all the location, design, and construction standards of the current City <br /> Codes, end which is operating satisfactorily by treating and disposing of the entire current sewage input <br /> without discharging any pollutants into ground or surface waters. <br /> 2 "Cd�iFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the <br /> current City Codes, but was installed according to the code in effect at the time of installation, and which <br /> is operating satisfactorily by treating and disposing of the entire current sewage input without discharging <br /> any pollutants into ground or surface waters. <br /> "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any <br /> system which mey or may not meet all the location, design, and construction standards of the current City <br /> Codes and which is failing for any reason; and any_system with less than 3 feet of unsaturated soil or sand <br /> between the distribution device and the limiting soil characteristics. <br /> (The limiting soil characteristic [ ) has or � has not been identified at this time. If the limiting soil <br /> characteristic has not been identified, this classification may be subject to revision.) <br /> TANK CONDiTION (5-10): <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 6 Solids accumulation in tanks indicates they should be punved out this year to help prevent future problems. <br /> 7 Solids accunulation in tanks is at a critical level. Tanks should be punped out as soon as possible. <br /> � System is discharging to the surface. Tanks must be punped out uithin 48 hours to eliminate surtace dischar�e. <br /> inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe> rtwst be instelled in each <br /> tank at next purpout. If tanks have not been punped out within the last three years, they should be punped <br /> out now. <br /> 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation>. <br /> lf tanks have not been punped out within the last three years, they should be punped out now. <br /> DRAINfIELD CONDITION (11-14): � <br /> �rainfietd inspection indicates: <br /> 11 Drainfield is dry, no surfacing evident. <br /> � � Sane evidence of surfacing, not critical yet. <br /> Drainfield is saturated and visibly discharging �treated effluent to the surface. Contact the Cit Ins tor <br /> immediately. Re ' <br /> 14 Drai nfitterE�terfr a co t t t on � nown. <br /> LIMITING SITE FACTORS (sloce,setbacks.etc.): <br /> POTEN?IAL FOR SYSTEM FAILURE (decends on soils.water table.etc.): <br /> COMMENTS��—�- �, � ��' �� <br /> Date of Inspection tic S s em Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, be advised that this report does not guarantee or certify that an existing system will continue to function <br /> properly� but is merely an opinion of the adequacy of the system under current conditions based on the evailable <br /> informat�on. <br /> This report must be kept on the premises with the system locstion and pu�ing records. <br /> WHITE COPYllnspectors File YELLOW COPY/Homeowner <br />
The URL can be used to link to this page
Your browser does not support the video tag.