Laserfiche WebLink
� o� <br /> 0 0 <br /> I �°� � CITY of ORONO <br /> i,a'�'���_'-- ,�v <br /> 1� R�!�� i.,� � <br /> �,,, � '��, r �lC� Municipai Offices <br /> '� /N�i�4"� ��"1�'�l" � <br /> ,� '�',,�1 '��``.� Street Addresr. Mailin� Address: <br /> 9k�;g"g0g' 2150 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> � <br /> owner: � ����� <br /> �� Address:4360 Sixth Ave. N. <br /> Permit #'s:427, 5341 Dates:ll/14/63, 10/3/78 Contractors:Widmer Bros., Fs. J. Petierson <br /> (This is [� an existing system [ ] new construction) <br /> SYSTEM COMPLIANCE (1-3) : 3 <br /> 1 Code Svstem: Meets or exceeds current City standards in all respects relating to <br /> design, construction, and location. Appears to be operating properly. <br /> 2 Compliant Svstem: Does not meet all current City standards for new construction, <br /> but in most respects appears to be designed, located, and constructed in accordance <br /> with previous codes and is functioning properly. <br /> � Non-Compliant Svstem: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the <br /> current input; and any system with less than three feet of vertical separation <br /> between the bottom of the drainfield and the saturated soil level. <br /> (The saturated soil level � has or [ ] has not been identified at this time. If the <br /> saturated soil level has not been identified, this classification is subject to revision.) <br /> TANK CONDITION (5-9) : 9 <br /> 5 Pumpout not needed at this time <br /> 6 Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been <br /> � pumped out within three years, they should be pumped out and risers installed now. <br /> Inspection pipe is located over tank baffle-can not measure solids accumulation. If <br /> tanks have not been pumped out within three years, they should be pumped out now. <br /> (During the last septic tank Maintenance Pumpout the tanka [ ] were or [� were not <br /> confirmed to be watertight by the licenaed pumping contractor. If the tanks were not <br /> confirmed to be watertight, this classification is subject to revision.) <br /> DRAINFIELD CONDITION (11-14) : 11 <br /> ]y Drainfield is dry, no surfacing evident. <br /> 12 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br /> Contact the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (svstem acfe and condition, soils, etc. ) : medium <br /> CONIl�IENTS: The non-compliant septic system must be repaired by 12/31/2006 or within 90 days <br /> of failure (surface discharge) , whichever comes first. <br /> R-�9'� '� , <br /> Date of Inspection S p c System Ins ector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue <br /> to function properly, but indicates the operation of the system under current conditions. <br /> Telep6one (612) 473-7357 • FAX 473-OS10 <br />