My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info
Orono
>
Property Files
>
Street Address
>
S
>
Sixth Avenue North
>
4320 Sixth Ave N - 31-118-23-12-0009
>
Septic
>
septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:28:45 PM
Creation date
2/14/2019 12:32:48 PM
Metadata
Fields
Template:
x Address Old
House Number
4320
Street Name
6th
Street Type
Avenue
Street Direction
North
Address
4320 6th Avenue North
Document Type
Septic
PIN
3111823120009
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
On tbe North Shore of <br /> Lake Minnetonka <br /> ON-SITE SEWAGE TREATMENT <br /> INSPECTION REPORT � POST OFFICE BOX 66 <br /> � _ � � 1335 S. Brown Rd. <br /> Crystal Bay,MN 55323 <br /> � 473-7357 <br /> OWNER ��'�T'��1'rbn a� 9 ADDRESS �3ao �f�,�. l(/t <br /> PERMIT NO.'S. -��73 DATES �2��s. CONTRACTORS S � � <br /> City Ordinance No.210 requirea that each oniite aewage treatment system in Orono be inspected on a regular baais.The onsite sewage <br /> treatment system at the above address has bee�inspected and appean to fsll into the category checked below. <br /> (This is � an exiating systern ❑ new construction) <br /> � � Meets or exceeds current City standerds in all reapects relating to design,construction,and location.Appears to be operating <br /> properly. <br /> �2 Does not meet all current City standarda for new conatruction (1978 Code) but in most respects appears to be designed, <br /> located, and conatructed generoily in accordance with previoua codes.System appears to be functioning properly;no major <br /> upg►ading of the systern is required at this time. <br /> � 3 Does not meet curre�t City standards in many respects relating to desig�,construction,or location.Appears to be operating <br /> adequately at this time,but has a relatively high potential for future problems. No major upgrading of system is required at <br /> this time. <br /> � 4 System may or may not meet current City standerds for design,construction or location,but is failing to properly treat and <br /> dispose of the current input,and is endengering a water supply,or is a source of pollution to surface or groundwaters,or is <br /> creating a aafety hezard,or is otherwise creating a public nuisance.Ple�e contect the City Inspector to discuss system repair/ <br /> replacement pro�dures. If drainfield replacement is necessary,soil testing wili usually be required,and a design and site plan <br /> must be submitted for review.Your contractor must obtain a permit before work is started. <br /> SYSTEM CONDITION�m Checked items may require your action) <br /> , ,Tank inapection indicatea: ❑ Inapection pipe is located directly over tank baffle.(Does not <br /> � �Pumpout not needed at this time. give accurate m�surement of solids accumulation.) If tanks <br /> ❑ Solids accumulation in tenks indicatea Mey should be pump- have not been pumped out within the laat three years,they <br /> ed out thia year to help prevent future problems. ehould be pumped out now. <br /> ❑ Solida acxumulation in tenks ia at a critical level. Tanks Drei field inapection indicates: <br /> should be pumped out as soon sa possible. �Drainfield is dry,no aurfacing evident. <br /> ❑ System is ditcharging to aurface. Tanka must be pumped ❑ Some avidence of surfaci�g,not critical yet. <br /> within 48 hours to eliminate surfece discharge. O Drainfield is aeturated and visibly discharging untreated <br /> ❑ Inspection riaero missing—tanka could not be inapected, effluent to the surfece, This condition may require replace- <br /> Inspection risera (4"dia, pipe)must be instetled in each tank ment or additions to drainfield. Contact the City Inspector <br /> at next pumpout. If tankt have not been pumped out within immediately.Repairs muat be completed within 90 days. <br /> the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown. <br /> SITE CHARACTERISTICS: <br /> Limiting Site Factors Potential for System Failure Site Capabilities for <br /> ❑ Slope (depends on soil types,water Future Expa�sion <br /> ❑ Soil table and system condition) Adequate <br /> ❑ High water table �l.ow �Fair <br /> ❑ Lot size ❑ Medium ❑Poor <br /> ❑ lake,wetland,or st►eam ❑ High . ❑ Inadequate <br /> ❑ Drainage ❑System is causing visible <br /> surface discharge. <br /> COMMENTS: ' � I�C � I/Y � <br /> �S 4 G <br /> � � i �G ' <br /> �-/7 9� <br /> Date of Inspection Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that <br /> this report dces not guarantee or certify that an exisfing systern will continue to functio�properly,but is merely an opi�ion of the adequacy <br /> of the system under current conditions based on the available information. <br /> This report must be kept on the premises with system location and pumping records. <br /> WHITE COPY/Inspector's File GOLD COPY/Homeowner <br />
The URL can be used to link to this page
Your browser does not support the video tag.