septic info
Orono
>
Property Files
>
Street Address
>
S
>
Sixth Avenue North
>
4225 Sixth Ave N - 31-118-23-12-0012
>
Septic
>
septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:28:50 PM
Creation date
2/13/2019 12:35:13 PM
Metadata
Fields
Template:
x Address Old
House Number
4225
Street Name
6th
Street Type
Avenue
Street Direction
North
Address
4225 6th Avenue North
Document Type
Septic
PIN
3111823120012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
On the North Sbore o f <br /> Lake Minnetonka <br /> ON-SITE SEWAGE TREATMENT <br /> INSPECTION REPORT � POST OFFICE BOX 66 <br /> 1335 S. Brown Rd. <br /> � � � Crystal Bay, MN 55323 <br /> 473-7357 <br /> OWNER //���1'� �' C�Vl7)P1'� ��'YOI ADDRESS ��� � e� <br /> PERMIT NO.'S. �7I DATES 3��1 CONTRACTORS �U�i�/.J�Y� <br /> City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The onsite sewage <br /> ueatment systern at the above address has been inspected and appears to fail into the category checked below. <br /> (This is �an existing system ❑ new construction) <br /> � � Meets or exoeeds curcent City standards in all respects relating to deaign,construction,and locetion.Appears to be operating <br /> properly. <br /> � 2 Does not meet all current City standards for �ew construction (1878 Code) but in most respects appears to be designed, <br /> locsted, and constructed generally in accordance with previous codes.System appears to be functioning properly;no major <br /> upgreding of the system is required at this time. <br /> � 3 Does nat meet current City standards in many respects relating to design,construction,or location.Appears to be operating <br /> adequately at this time,but has a relatively high potential for future problems. No major upgrading of system is required at <br /> this time. <br /> �4 System may or may �ot meet current City standards for design,construction or location,but is failing to properly treat and <br /> dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is <br /> creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ <br /> replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan <br /> must be submitted for review.Your contractor must obtain a permit before work is started. <br /> SYSTEM CONDITION ( m Checked items may�equire your action) <br /> Tank inspection indicates: ❑ Inspection pipe is located directly over tank beffte.(Does not <br /> � ❑ Pumpout not needed at thia time. give accurate measurement of solids eccumulation.) If tanks <br /> �Solida accumulation in tsnks indicates they should be pump- have �ot been pumped out within the last three years,they <br /> ed out this year to help prevent future problems. ahould be pumped out now. <br /> ❑ Solids eccumulation in tanks is at a critical level. Tenks Drainfield inspection indicates: <br /> should be pumped out as soon as possible. ❑ Drainfield is dry,no surfacing evident. <br /> ❑ System is discharging to surface. Tanks must be pumped Some evidence of surfacing,not critical yet. <br /> within 48 hours to eliminate surfa�discharge. �.Drainfield is saturated and visibly discharging untreated <br /> ❑ Inspection risera missing—tanks could not be inspected, effluent to the surface. This condition may require replace- <br /> Inspection risera (4"dia.pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector <br /> at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. <br /> the last three years,they should be pumped out now. ❑ Dreinfield extent and condition unknown, <br /> SITE CHARACTERISTICS: <br /> Limiting Site Factors Potential for System Failure Site Capabilities for <br /> ❑ Slope (depends on soil types,water Future Expansion <br /> ❑ Soil table,and system condition) �Adequate <br /> ❑ High water table ❑ Low ❑ Fair <br /> ❑ Lot size ❑Medium O Poor <br /> ❑ Lake,wetland,or stream �] High ❑ Inadequate <br /> ❑ Drainage �-System is causing visible <br /> surface discharge. <br /> COMMENTS: S � 0 � <br /> �P G 'G � <br /> . /�' <br /> �-/ <br /> Date of Inspection Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that <br /> this report does not guarentee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy <br /> of the system under current conditions based on the available information. <br /> This report must be kept o�the premises with system locetion and pumping records. <br /> WHITE COPY/Inspector's File GOLD COPY/Homeowner <br />
The URL can be used to link to this page
Your browser does not support the video tag.